Radius of flushing hole Formula

Fx Copy
LaTeX Copy
Radius of flushing hole is the radius of flushing hole in EDM. Check FAQs
R1=R0exp(π(P1-Patm)h3Q6μv)
R1 - Radius of Flushing Hole?R0 - Radius of the Electrodes?P1 - Pressure in Flushing Hole?Patm - Atmospheric Pressure?h - Gap Spacing?Q - Flow Rate of the Electrolyte?μv - Dynamic Viscosity?π - Archimedes' constant?

Radius of flushing hole Example

With values
With units
Only example

Here is how the Radius of flushing hole equation looks like with Values.

Here is how the Radius of flushing hole equation looks like with Units.

Here is how the Radius of flushing hole equation looks like.

3.98Edit=5Editexp(3.1416(11Edit-10Edit)2Edit30.18Edit610.2Edit)
You are here -
HomeIcon Home » Category Engineering » Category Production Engineering » Category Unconventional machining processes » fx Radius of flushing hole

Radius of flushing hole Solution

Follow our step by step solution on how to calculate Radius of flushing hole?

FIRST Step Consider the formula
R1=R0exp(π(P1-Patm)h3Q6μv)
Next Step Substitute values of Variables
R1=5cmexp(π(11N/cm²-10N/cm²)2cm30.18m³/s610.2P)
Next Step Substitute values of Constants
R1=5cmexp(3.1416(11N/cm²-10N/cm²)2cm30.18m³/s610.2P)
Next Step Convert Units
R1=0.05mexp(3.1416(110000Pa-100000Pa)0.02m30.18m³/s61.02Pa*s)
Next Step Prepare to Evaluate
R1=0.05exp(3.1416(110000-100000)0.0230.1861.02)
Next Step Evaluate
R1=0.0398003374456498m
Next Step Convert to Output's Unit
R1=3.98003374456498cm
LAST Step Rounding Answer
R1=3.98cm

Radius of flushing hole Formula Elements

Variables
Constants
Functions
Radius of Flushing Hole
Radius of flushing hole is the radius of flushing hole in EDM.
Symbol: R1
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Radius of the Electrodes
Radius of the electrodes is defined as the radius of the electrode used for unconventional machining by EDM.
Symbol: R0
Measurement: LengthUnit: cm
Note: Value can be positive or negative.
Pressure in Flushing Hole
Pressure in Flushing Hole is the pressure in hole during EDM machining.
Symbol: P1
Measurement: PressureUnit: N/cm²
Note: Value should be greater than 0.
Atmospheric Pressure
Atmospheric pressure, also known as barometric pressure, is the pressure within the atmosphere of Earth.
Symbol: Patm
Measurement: PressureUnit: N/cm²
Note: Value can be positive or negative.
Gap Spacing
Gap spacing is the width of distance between electrode and work during EDM.
Symbol: h
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Flow Rate of the Electrolyte
Flow rate of the electrolyte is the flow rate of the electrolyte used in EDM.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Dynamic Viscosity
The Dynamic Viscosity of a fluid is the measure of its resistance to flow when an external force is applied.
Symbol: μv
Measurement: Dynamic ViscosityUnit: P
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288
exp
n an exponential function, the value of the function changes by a constant factor for every unit change in the independent variable.
Syntax: exp(Number)

Other formulas in Flow rate of the electrolyte category

​Go Flow rate of electrolyte
Q=π(P1-Patm)h36μvln(R0R1)
​Go Gap spacing
h=(Q6μvln(R0R1)π(P1-Patm))13

How to Evaluate Radius of flushing hole?

Radius of flushing hole evaluator uses Radius of Flushing Hole = Radius of the Electrodes/exp((pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(Flow Rate of the Electrolyte*6*Dynamic Viscosity)) to evaluate the Radius of Flushing Hole, The Radius of flushing hole formula is defined as the radius of the hollow part of electrode which contains the entrance/exit to the dielectric fluid. Radius of Flushing Hole is denoted by R1 symbol.

How to evaluate Radius of flushing hole using this online evaluator? To use this online evaluator for Radius of flushing hole, enter Radius of the Electrodes (R0), Pressure in Flushing Hole (P1), Atmospheric Pressure (Patm), Gap Spacing (h), Flow Rate of the Electrolyte (Q) & Dynamic Viscosity v) and hit the calculate button.

FAQs on Radius of flushing hole

What is the formula to find Radius of flushing hole?
The formula of Radius of flushing hole is expressed as Radius of Flushing Hole = Radius of the Electrodes/exp((pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(Flow Rate of the Electrolyte*6*Dynamic Viscosity)). Here is an example- 493.2022 = 0.05/exp((pi*(110000-100000)*0.02^3)/(0.18*6*1.02)).
How to calculate Radius of flushing hole?
With Radius of the Electrodes (R0), Pressure in Flushing Hole (P1), Atmospheric Pressure (Patm), Gap Spacing (h), Flow Rate of the Electrolyte (Q) & Dynamic Viscosity v) we can find Radius of flushing hole using the formula - Radius of Flushing Hole = Radius of the Electrodes/exp((pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(Flow Rate of the Electrolyte*6*Dynamic Viscosity)). This formula also uses Archimedes' constant and Exponential Growth (exp) function(s).
Can the Radius of flushing hole be negative?
No, the Radius of flushing hole, measured in Length cannot be negative.
Which unit is used to measure Radius of flushing hole?
Radius of flushing hole is usually measured using the Centimeter[cm] for Length. Meter[cm], Millimeter[cm], Kilometer[cm] are the few other units in which Radius of flushing hole can be measured.
Copied!