Fx Copy
LaTeX Copy
Radial Distance at Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used. Check FAQs
R2=r1102.72Tenvi(h2-h1)Q0
R2 - Radial Distance at Well 2?r1 - Radial Distance at Observation Well 1?Tenvi - Coefficient of Transmissibility?h2 - Depth of Water 2?h1 - Depth of Water 1?Q0 - Discharge at Time t=0?

Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge Example

With values
With units
Only example

Here is how the Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge equation looks like with Values.

Here is how the Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge equation looks like with Units.

Here is how the Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge equation looks like.

1.0729Edit=1.07Edit102.721.5Edit(17.8644Edit-17.85Edit)50Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge

Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge Solution

Follow our step by step solution on how to calculate Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge?

FIRST Step Consider the formula
R2=r1102.72Tenvi(h2-h1)Q0
Next Step Substitute values of Variables
R2=1.07m102.721.5m²/s(17.8644m-17.85m)50m³/s
Next Step Prepare to Evaluate
R2=1.07102.721.5(17.8644-17.85)50
Next Step Evaluate
R2=1.07289894362417m
LAST Step Rounding Answer
R2=1.0729m

Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge Formula Elements

Variables
Radial Distance at Well 2
Radial Distance at Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used.
Symbol: R2
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radial Distance at Observation Well 1
Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
Symbol: r1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Coefficient of Transmissibility
Coefficient of Transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Symbol: Tenvi
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value should be greater than 0.
Depth of Water 2
Depth of water 2 means the depth of the water in 2nd well.
Symbol: h2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Depth of Water 1
Depth of Water 1 is the depth of water in the 1st considered well.
Symbol: h1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Discharge at Time t=0
Discharge at Time t=0 is the rate of flow of a liquid that moves over a designated point over a fixed period.
Symbol: Q0
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other Formulas to find Radial Distance at Well 2

​Go Radial Distance of Well 2 given Confined Aquifer Discharge
R2=r1102.72KWHbp(h2-h1)Q0

Other formulas in Radial Distance and Radius of well category

​Go Radius of Well given Discharge in Confined Aquifer
rw=Rwexp(2πKWHbp(Hi-hw)Q0)
​Go Radius of Well for Discharge in Confined Aquifer with Base 10
rw=Rw102.72Kswhb(Hi-hw)Q
​Go Radius of Well given Coefficient of Transmissibility
rw=Rwexp(2πTenvi(Hi-hw)Q0)
​Go Radius of Well given Coefficient of Transmissibility with Base 10
rw=Rw102.72Tenvi(Hi-hw)Q0

How to Evaluate Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge?

Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge evaluator uses Radial Distance at Well 2 = Radial Distance at Observation Well 1*10^((2.72*Coefficient of Transmissibility*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0) to evaluate the Radial Distance at Well 2, The Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge is defined as the value of radial distance from 2nd well when we have prior information of other parameters used. Radial Distance at Well 2 is denoted by R2 symbol.

How to evaluate Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge using this online evaluator? To use this online evaluator for Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge, enter Radial Distance at Observation Well 1 (r1), Coefficient of Transmissibility (Tenvi), Depth of Water 2 (h2), Depth of Water 1 (h1) & Discharge at Time t=0 (Q0) and hit the calculate button.

FAQs on Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge

What is the formula to find Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge?
The formula of Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge is expressed as Radial Distance at Well 2 = Radial Distance at Observation Well 1*10^((2.72*Coefficient of Transmissibility*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0). Here is an example- 1.072899 = 1.07*10^((2.72*1.5*(17.8644-17.85))/50).
How to calculate Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge?
With Radial Distance at Observation Well 1 (r1), Coefficient of Transmissibility (Tenvi), Depth of Water 2 (h2), Depth of Water 1 (h1) & Discharge at Time t=0 (Q0) we can find Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge using the formula - Radial Distance at Well 2 = Radial Distance at Observation Well 1*10^((2.72*Coefficient of Transmissibility*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0).
What are the other ways to Calculate Radial Distance at Well 2?
Here are the different ways to Calculate Radial Distance at Well 2-
  • Radial Distance at Well 2=Radial Distance at Observation Well 1*10^((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0)OpenImg
Can the Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge be negative?
No, the Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge, measured in Length cannot be negative.
Which unit is used to measure Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge?
Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge can be measured.
Copied!