Fx Copy
LaTeX Copy
Radial Distance 1 is the value of radial distance from well 1 when we have prior information of other parameters used. Check FAQs
R1=r2102.72KWHbp(h2-h1)Q0
R1 - Radial Distance 1?r2 - Radial Distance at Observation Well 2?KWH - Coefficient of Permeability in Well Hydraulics?bp - Aquifer Thickness During Pumping?h2 - Depth of Water 2?h1 - Depth of Water 1?Q0 - Discharge at Time t=0?

Radial Distance of Well 1 given Confined Aquifer Discharge Example

With values
With units
Only example

Here is how the Radial Distance of Well 1 given Confined Aquifer Discharge equation looks like with Values.

Here is how the Radial Distance of Well 1 given Confined Aquifer Discharge equation looks like with Units.

Here is how the Radial Distance of Well 1 given Confined Aquifer Discharge equation looks like.

9.9957Edit=10Edit102.7210Edit2.36Edit(17.8644Edit-17.85Edit)50Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Radial Distance of Well 1 given Confined Aquifer Discharge

Radial Distance of Well 1 given Confined Aquifer Discharge Solution

Follow our step by step solution on how to calculate Radial Distance of Well 1 given Confined Aquifer Discharge?

FIRST Step Consider the formula
R1=r2102.72KWHbp(h2-h1)Q0
Next Step Substitute values of Variables
R1=10m102.7210cm/s2.36m(17.8644m-17.85m)50m³/s
Next Step Convert Units
R1=10m102.720.1m/s2.36m(17.8644m-17.85m)50m³/s
Next Step Prepare to Evaluate
R1=10102.720.12.36(17.8644-17.85)50
Next Step Evaluate
R1=9.99574404869518m
LAST Step Rounding Answer
R1=9.9957m

Radial Distance of Well 1 given Confined Aquifer Discharge Formula Elements

Variables
Radial Distance 1
Radial Distance 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
Symbol: R1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Radial Distance at Observation Well 2
Radial Distance at Observation Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used.
Symbol: r2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Coefficient of Permeability in Well Hydraulics
Coefficient of Permeability in Well Hydraulics of soil in well hydraulics describes how easily a liquid will move through the soil.
Symbol: KWH
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Aquifer Thickness During Pumping
Aquifer Thickness During Pumping is the thickness of aquifer during pumping stage.
Symbol: bp
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Depth of Water 2
Depth of water 2 means the depth of the water in 2nd well.
Symbol: h2
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Depth of Water 1
Depth of Water 1 is the depth of water in the 1st considered well.
Symbol: h1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Discharge at Time t=0
Discharge at Time t=0 is the rate of flow of a liquid that moves over a designated point over a fixed period.
Symbol: Q0
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other Formulas to find Radial Distance 1

​Go Radial Distance of Well 1 given Coefficient of Transmissibility and Discharge
R1=r2102.72Tenvi(h2-h1)Q0

Other formulas in Radial Distance and Radius of well category

​Go Radius of Well given Discharge in Confined Aquifer
rw=Rwexp(2πKWHbp(Hi-hw)Q0)
​Go Radius of Well for Discharge in Confined Aquifer with Base 10
rw=Rw102.72Kswhb(Hi-hw)Q

How to Evaluate Radial Distance of Well 1 given Confined Aquifer Discharge?

Radial Distance of Well 1 given Confined Aquifer Discharge evaluator uses Radial Distance 1 = Radial Distance at Observation Well 2/10^((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0) to evaluate the Radial Distance 1, The Radial Distance of Well 1 given Confined Aquifer Discharge is defined as the value of radial distance from 1st well when we have prior information of other parameters used. Radial Distance 1 is denoted by R1 symbol.

How to evaluate Radial Distance of Well 1 given Confined Aquifer Discharge using this online evaluator? To use this online evaluator for Radial Distance of Well 1 given Confined Aquifer Discharge, enter Radial Distance at Observation Well 2 (r2), Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness During Pumping (bp), Depth of Water 2 (h2), Depth of Water 1 (h1) & Discharge at Time t=0 (Q0) and hit the calculate button.

FAQs on Radial Distance of Well 1 given Confined Aquifer Discharge

What is the formula to find Radial Distance of Well 1 given Confined Aquifer Discharge?
The formula of Radial Distance of Well 1 given Confined Aquifer Discharge is expressed as Radial Distance 1 = Radial Distance at Observation Well 2/10^((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0). Here is an example- 9.995744 = 10/10^((2.72*0.1*2.36*(17.8644-17.85))/50).
How to calculate Radial Distance of Well 1 given Confined Aquifer Discharge?
With Radial Distance at Observation Well 2 (r2), Coefficient of Permeability in Well Hydraulics (KWH), Aquifer Thickness During Pumping (bp), Depth of Water 2 (h2), Depth of Water 1 (h1) & Discharge at Time t=0 (Q0) we can find Radial Distance of Well 1 given Confined Aquifer Discharge using the formula - Radial Distance 1 = Radial Distance at Observation Well 2/10^((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0).
What are the other ways to Calculate Radial Distance 1?
Here are the different ways to Calculate Radial Distance 1-
  • Radial Distance 1=Radial Distance at Observation Well 2/10^((2.72*Coefficient of Transmissibility*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0)OpenImg
Can the Radial Distance of Well 1 given Confined Aquifer Discharge be negative?
No, the Radial Distance of Well 1 given Confined Aquifer Discharge, measured in Length cannot be negative.
Which unit is used to measure Radial Distance of Well 1 given Confined Aquifer Discharge?
Radial Distance of Well 1 given Confined Aquifer Discharge is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Radial Distance of Well 1 given Confined Aquifer Discharge can be measured.
Copied!