Q-Factor of Loaded Catcher Cavity Formula

Fx Copy
LaTeX Copy
Q Factor of Loaded Catcher Cavity is defined as a measure of the strength of the damping of its oscillations. Check FAQs
QL=(1Qo)+(1Qb)+(1Qel)
QL - Q Factor of Loaded Catcher Cavity?Qo - Q Factor of Catcher Wall?Qb - Q Factor of Beam Loading?Qel - Q Factor of External Load?

Q-Factor of Loaded Catcher Cavity Example

With values
With units
Only example

Here is how the Q-Factor of Loaded Catcher Cavity equation looks like with Values.

Here is how the Q-Factor of Loaded Catcher Cavity equation looks like with Units.

Here is how the Q-Factor of Loaded Catcher Cavity equation looks like.

2.2405Edit=(11.25Edit)+(10.8Edit)+(15.25Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Microwave Theory » fx Q-Factor of Loaded Catcher Cavity

Q-Factor of Loaded Catcher Cavity Solution

Follow our step by step solution on how to calculate Q-Factor of Loaded Catcher Cavity?

FIRST Step Consider the formula
QL=(1Qo)+(1Qb)+(1Qel)
Next Step Substitute values of Variables
QL=(11.25)+(10.8)+(15.25)
Next Step Prepare to Evaluate
QL=(11.25)+(10.8)+(15.25)
Next Step Evaluate
QL=2.24047619047619
LAST Step Rounding Answer
QL=2.2405

Q-Factor of Loaded Catcher Cavity Formula Elements

Variables
Q Factor of Loaded Catcher Cavity
Q Factor of Loaded Catcher Cavity is defined as a measure of the strength of the damping of its oscillations.
Symbol: QL
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Q Factor of Catcher Wall
Q Factor of Catcher Wall is defined as a measure of the strength of the damping of its oscillations, or for the relative line width Of Catcher Wall.
Symbol: Qo
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Q Factor of Beam Loading
Q Factor of Beam Loading is defined as a measure of the strength of the damping of its oscillations, or for the relative linewidth Of Beam Loading.
Symbol: Qb
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Q Factor of External Load
Q Factor of External Load is defined as a measure of the strength of the damping of its oscillations, or for the relative linewidth Of External Load.
Symbol: Qel
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Q Factor category

​Go Quality Factor of Cavity Resonator
Qc=ωrf2-f1
​Go Q-Factor of Catcher Wall
Qo=1QL-(1Qb)-(1Qel)
​Go Q-Factor of Beam Loading
Qb=1QL-(1Qo)-(1Qel)
​Go Q-Factor of External Load
Qel=1QL-(1Qb)-(1Qo)

How to Evaluate Q-Factor of Loaded Catcher Cavity?

Q-Factor of Loaded Catcher Cavity evaluator uses Q Factor of Loaded Catcher Cavity = (1/Q Factor of Catcher Wall)+(1/Q Factor of Beam Loading)+(1/Q Factor of External Load) to evaluate the Q Factor of Loaded Catcher Cavity, The Q-Factor of Loaded Catcher Cavity formula is defined as a measure of the strength of the damping of its oscillations, or for the relative linewidth Of Loaded Catcher Cavity. Q Factor of Loaded Catcher Cavity is denoted by QL symbol.

How to evaluate Q-Factor of Loaded Catcher Cavity using this online evaluator? To use this online evaluator for Q-Factor of Loaded Catcher Cavity, enter Q Factor of Catcher Wall (Qo), Q Factor of Beam Loading (Qb) & Q Factor of External Load (Qel) and hit the calculate button.

FAQs on Q-Factor of Loaded Catcher Cavity

What is the formula to find Q-Factor of Loaded Catcher Cavity?
The formula of Q-Factor of Loaded Catcher Cavity is expressed as Q Factor of Loaded Catcher Cavity = (1/Q Factor of Catcher Wall)+(1/Q Factor of Beam Loading)+(1/Q Factor of External Load). Here is an example- 2.240476 = (1/1.25)+(1/0.8)+(1/5.25).
How to calculate Q-Factor of Loaded Catcher Cavity?
With Q Factor of Catcher Wall (Qo), Q Factor of Beam Loading (Qb) & Q Factor of External Load (Qel) we can find Q-Factor of Loaded Catcher Cavity using the formula - Q Factor of Loaded Catcher Cavity = (1/Q Factor of Catcher Wall)+(1/Q Factor of Beam Loading)+(1/Q Factor of External Load).
Copied!