Fx Copy
LaTeX Copy
The Pumping Rate is referred as volume of water (or other fluid) that is pumped per unit of time. It’s typically measured in units like liters per second (L/s) or cubic meters per hour (m³/h). Check FAQs
q=TΔs70
q - Pumping Rate?T - Transmissivity?Δs - Drawdown Across One Log Cycle?

Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs Example

With values
With units
Only example

Here is how the Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs equation looks like with Values.

Here is how the Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs equation looks like with Units.

Here is how the Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs equation looks like.

7.0007Edit=11Edit44.55Edit70
You are here -

Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs Solution

Follow our step by step solution on how to calculate Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs?

FIRST Step Consider the formula
q=TΔs70
Next Step Substitute values of Variables
q=11m²/s44.5570
Next Step Prepare to Evaluate
q=1144.5570
Next Step Evaluate
q=7.00071428571429m³/s
LAST Step Rounding Answer
q=7.0007m³/s

Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs Formula Elements

Variables
Pumping Rate
The Pumping Rate is referred as volume of water (or other fluid) that is pumped per unit of time. It’s typically measured in units like liters per second (L/s) or cubic meters per hour (m³/h).
Symbol: q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Transmissivity
Transmissivity is the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it.
Symbol: T
Measurement: Kinematic ViscosityUnit: m²/s
Note: Value can be positive or negative.
Drawdown Across One Log Cycle
The Drawdown Across One Log Cycle is referred as change in water level (or hydraulic head) in an aquifer due to pumping from a well.
Symbol: Δs
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Pumping Rate

​Go Pumping Rate from Distance Drawdown Graphs
q=T2πΔsD2.3

Other formulas in Distance Drawdown Analysis category

​Go Transmissivity from Distance Drawdown Graphs
T=2.3q2πΔsD
​Go Storage Coefficient from Distance-Drawdown Graphs
S=2.25Tstro2
​Go Drawdown across One Log Cycle from Distance Drawdown Graphs given Transmissivity
ΔsD=2.3qT2π
​Go Transmissivity given Storage Coefficient from Distance Drawdown
T=Sro22.25st

How to Evaluate Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs?

Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs evaluator uses Pumping Rate = Transmissivity*Drawdown Across One Log Cycle/70 to evaluate the Pumping Rate, The Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs formula is defined as the rate at which a well is pumped at a controlled rate and drawdown is measured in one or more surrounding observation wells. Pumping Rate is denoted by q symbol.

How to evaluate Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs using this online evaluator? To use this online evaluator for Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs, enter Transmissivity (T) & Drawdown Across One Log Cycle (Δs) and hit the calculate button.

FAQs on Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs

What is the formula to find Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs?
The formula of Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs is expressed as Pumping Rate = Transmissivity*Drawdown Across One Log Cycle/70. Here is an example- 7.000714 = 11*44.55/70.
How to calculate Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs?
With Transmissivity (T) & Drawdown Across One Log Cycle (Δs) we can find Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs using the formula - Pumping Rate = Transmissivity*Drawdown Across One Log Cycle/70.
What are the other ways to Calculate Pumping Rate?
Here are the different ways to Calculate Pumping Rate-
  • Pumping Rate=Transmissivity*2*pi*Drawdown Across Log Cycle/2.3OpenImg
Can the Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs be negative?
Yes, the Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs?
Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Pumping Rate given Transmissivity for Inconsistent Units from Distance-Drawdown Graphs can be measured.
Copied!