Provision for Thermal Expansion and Contraction in Heat Exchanger Formula

Fx Copy
LaTeX Copy
Thermal expansion refers to the tendency of material to change its size, shape, or volume in response to a change in temperature. Check FAQs
ΔL=(97.110-6)LTubeΔTC
ΔL - Thermal Expansion?LTube - Length of Tube?ΔTC - Temperature Difference?

Provision for Thermal Expansion and Contraction in Heat Exchanger Example

With values
With units
Only example

Here is how the Provision for Thermal Expansion and Contraction in Heat Exchanger equation looks like with Values.

Here is how the Provision for Thermal Expansion and Contraction in Heat Exchanger equation looks like with Units.

Here is how the Provision for Thermal Expansion and Contraction in Heat Exchanger equation looks like.

17.9149Edit=(97.110-6)4500Edit41Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Provision for Thermal Expansion and Contraction in Heat Exchanger

Provision for Thermal Expansion and Contraction in Heat Exchanger Solution

Follow our step by step solution on how to calculate Provision for Thermal Expansion and Contraction in Heat Exchanger?

FIRST Step Consider the formula
ΔL=(97.110-6)LTubeΔTC
Next Step Substitute values of Variables
ΔL=(97.110-6)4500mm41K
Next Step Convert Units
ΔL=(97.110-6)4.5m41K
Next Step Prepare to Evaluate
ΔL=(97.110-6)4.541
Next Step Evaluate
ΔL=0.01791495m
Next Step Convert to Output's Unit
ΔL=17.91495mm
LAST Step Rounding Answer
ΔL=17.9149mm

Provision for Thermal Expansion and Contraction in Heat Exchanger Formula Elements

Variables
Thermal Expansion
Thermal expansion refers to the tendency of material to change its size, shape, or volume in response to a change in temperature.
Symbol: ΔL
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Length of Tube
Length of tube is the length which will be used during heat transfer in a exchanger.
Symbol: LTube
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Temperature Difference
Temperature Difference is the change in temperature of fluid passing through a heat exchanger.
Symbol: ΔTC
Measurement: TemperatureUnit: K
Note: Value should be greater than 0.

Other formulas in Basic Formulas of Heat Exchanger Designs category

​Go Equivalent Diameter for Square Pitch in Heat Exchanger
De=(1.27DOuter)((PTube2)-0.785(DOuter2))
​Go Equivalent Diameter for Triangular Pitch in Heat Exchanger
De=(1.10DOuter)((PTube2)-0.917(DOuter2))
​Go Number of Baffles in Shell and Tube Heat Exchanger
NBaffles=(LTubeLBaffle)-1
​Go Number of Tubes in Center Row Given Bundle Diameter and Tube Pitch
Nr=DBPTube

How to Evaluate Provision for Thermal Expansion and Contraction in Heat Exchanger?

Provision for Thermal Expansion and Contraction in Heat Exchanger evaluator uses Thermal Expansion = (97.1*10^-6)*Length of Tube*Temperature Difference to evaluate the Thermal Expansion, The Provision for Thermal Expansion and Contraction in Heat Exchanger formula is refers to the design and engineering practices put in place to accommodate and manage the changes in size, shape, or volume of the heat exchanger components as a result of temperature variations during its operation. Thermal Expansion is denoted by ΔL symbol.

How to evaluate Provision for Thermal Expansion and Contraction in Heat Exchanger using this online evaluator? To use this online evaluator for Provision for Thermal Expansion and Contraction in Heat Exchanger, enter Length of Tube (LTube) & Temperature Difference (ΔTC) and hit the calculate button.

FAQs on Provision for Thermal Expansion and Contraction in Heat Exchanger

What is the formula to find Provision for Thermal Expansion and Contraction in Heat Exchanger?
The formula of Provision for Thermal Expansion and Contraction in Heat Exchanger is expressed as Thermal Expansion = (97.1*10^-6)*Length of Tube*Temperature Difference. Here is an example- -101437.9425 = (97.1*10^-6)*4.5*41.
How to calculate Provision for Thermal Expansion and Contraction in Heat Exchanger?
With Length of Tube (LTube) & Temperature Difference (ΔTC) we can find Provision for Thermal Expansion and Contraction in Heat Exchanger using the formula - Thermal Expansion = (97.1*10^-6)*Length of Tube*Temperature Difference.
Can the Provision for Thermal Expansion and Contraction in Heat Exchanger be negative?
No, the Provision for Thermal Expansion and Contraction in Heat Exchanger, measured in Length cannot be negative.
Which unit is used to measure Provision for Thermal Expansion and Contraction in Heat Exchanger?
Provision for Thermal Expansion and Contraction in Heat Exchanger is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Provision for Thermal Expansion and Contraction in Heat Exchanger can be measured.
Copied!