Projection of Base Plate beyond Flange and Perpendicular to Web Formula

Fx Copy
LaTeX Copy
Projection of base plate beyond edge is distance between base plate beyond edges of the flange and perpendicular to the web. Check FAQs
n=t2Pu0.9FyBN
n - Projection of Base Plate Beyond Edge?t - Thickness?Pu - Factored Load?Fy - Yield Load?B - Width?N - Length?

Projection of Base Plate beyond Flange and Perpendicular to Web Example

With values
With units
Only example

Here is how the Projection of Base Plate beyond Flange and Perpendicular to Web equation looks like with Values.

Here is how the Projection of Base Plate beyond Flange and Perpendicular to Web equation looks like with Units.

Here is how the Projection of Base Plate beyond Flange and Perpendicular to Web equation looks like.

72.2939Edit=33Edit239381Edit0.9350Edit40Edit30Edit
You are here -

Projection of Base Plate beyond Flange and Perpendicular to Web Solution

Follow our step by step solution on how to calculate Projection of Base Plate beyond Flange and Perpendicular to Web?

FIRST Step Consider the formula
n=t2Pu0.9FyBN
Next Step Substitute values of Variables
n=33mm239381kN0.9350kN40mm30mm
Next Step Prepare to Evaluate
n=332393810.93504030
Next Step Evaluate
n=0.0722938696961407m
Next Step Convert to Output's Unit
n=72.2938696961407mm
LAST Step Rounding Answer
n=72.2939mm

Projection of Base Plate beyond Flange and Perpendicular to Web Formula Elements

Variables
Functions
Projection of Base Plate Beyond Edge
Projection of base plate beyond edge is distance between base plate beyond edges of the flange and perpendicular to the web.
Symbol: n
Measurement: LengthUnit: mm
Note: Value can be positive or negative.
Thickness
The thickness of the base plate.
Symbol: t
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Factored Load
Factored Load is a load multiplied by a certain factor designated by codes of practice to determine the strength of a structural members.
Symbol: Pu
Measurement: ForceUnit: kN
Note: Value can be positive or negative.
Yield Load
Yield load is the load value at the point of yield; that is, where plastic deformation begins in stress strain curve.
Symbol: Fy
Measurement: ForceUnit: kN
Note: Value can be positive or negative.
Width
The width is parallel to the flanges.
Symbol: B
Measurement: LengthUnit: mm
Note: Value can be positive or negative.
Length
The length of a rectangular base plate for a wide-flange column.
Symbol: N
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Column Base Plate Design category

​Go Specified Compressive Strength of Concrete using Nominal Bearing Strength
f'c=(fp0.85)A1A2
​Go Nominal Bearing Strength of Concrete
fp=f'c0.85A2A1
​Go Area of Base Plate given Nominal Bearing Strength
A1=A2(fpf'c0.85)2
​Go Area of Supporting Concrete given Nominal Bearing Strength
A2=A1((fpf'c0.85)2)

How to Evaluate Projection of Base Plate beyond Flange and Perpendicular to Web?

Projection of Base Plate beyond Flange and Perpendicular to Web evaluator uses Projection of Base Plate Beyond Edge = Thickness/(sqrt(2*Factored Load/(0.9*Yield Load*Width*Length))) to evaluate the Projection of Base Plate Beyond Edge, The Projection of Base Plate beyond Flange and Perpendicular to Web formula is defined as the distance between the base plate beyond the edges of the flange and perpendicular to the web. Projection of Base Plate Beyond Edge is denoted by n symbol.

How to evaluate Projection of Base Plate beyond Flange and Perpendicular to Web using this online evaluator? To use this online evaluator for Projection of Base Plate beyond Flange and Perpendicular to Web, enter Thickness (t), Factored Load (Pu), Yield Load (Fy), Width (B) & Length (N) and hit the calculate button.

FAQs on Projection of Base Plate beyond Flange and Perpendicular to Web

What is the formula to find Projection of Base Plate beyond Flange and Perpendicular to Web?
The formula of Projection of Base Plate beyond Flange and Perpendicular to Web is expressed as Projection of Base Plate Beyond Edge = Thickness/(sqrt(2*Factored Load/(0.9*Yield Load*Width*Length))). Here is an example- 72293.87 = 0.033/(sqrt(2*39381000/(0.9*350000*0.04*0.03))).
How to calculate Projection of Base Plate beyond Flange and Perpendicular to Web?
With Thickness (t), Factored Load (Pu), Yield Load (Fy), Width (B) & Length (N) we can find Projection of Base Plate beyond Flange and Perpendicular to Web using the formula - Projection of Base Plate Beyond Edge = Thickness/(sqrt(2*Factored Load/(0.9*Yield Load*Width*Length))). This formula also uses Square Root (sqrt) function(s).
Can the Projection of Base Plate beyond Flange and Perpendicular to Web be negative?
Yes, the Projection of Base Plate beyond Flange and Perpendicular to Web, measured in Length can be negative.
Which unit is used to measure Projection of Base Plate beyond Flange and Perpendicular to Web?
Projection of Base Plate beyond Flange and Perpendicular to Web is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Projection of Base Plate beyond Flange and Perpendicular to Web can be measured.
Copied!