Fx Copy
LaTeX Copy
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work. Check FAQs
P=IVmcos(Φ)2
P - Power Transmitted?I - Current Underground AC?Vm - Maximum Voltage Underground AC?Φ - Phase Difference?

Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) Example

With values
With units
Only example

Here is how the Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Values.

Here is how the Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Units.

Here is how the Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) equation looks like.

1267.6109Edit=9Edit230Editcos(30Edit)2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed)

Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) Solution

Follow our step by step solution on how to calculate Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed)?

FIRST Step Consider the formula
P=IVmcos(Φ)2
Next Step Substitute values of Variables
P=9A230Vcos(30°)2
Next Step Convert Units
P=9A230Vcos(0.5236rad)2
Next Step Prepare to Evaluate
P=9230cos(0.5236)2
Next Step Evaluate
P=1267.61094189029W
LAST Step Rounding Answer
P=1267.6109W

Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) Formula Elements

Variables
Functions
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Maximum Voltage Underground AC
Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Power Transmitted

​Go Power Transmitted using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
P=APloss(Vmcos(Φ))24ρL
​Go Power Transmitted using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
P=Ploss2R(Vmcos(Φ)2)

Other formulas in Power and Power Factor category

​Go Power Factor using Load Current (1-Phase 2-Wire Mid-Point Earthed)
PF=2PIVm
​Go Power Factor using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
PF=4(P2)RPloss(Vm2)
​Go Power Factor using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
PF=4(P2)ρLAPloss(Vm2)

How to Evaluate Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed)?

Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) evaluator uses Power Transmitted = Current Underground AC*Maximum Voltage Underground AC*cos(Phase Difference)/sqrt(2) to evaluate the Power Transmitted, The Power Transmitted using Load Current (1-phase 2-wire Mid-point Earthed) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations. Power Transmitted is denoted by P symbol.

How to evaluate Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) using this online evaluator? To use this online evaluator for Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed), enter Current Underground AC (I), Maximum Voltage Underground AC (Vm) & Phase Difference (Φ) and hit the calculate button.

FAQs on Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed)

What is the formula to find Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed)?
The formula of Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) is expressed as Power Transmitted = Current Underground AC*Maximum Voltage Underground AC*cos(Phase Difference)/sqrt(2). Here is an example- 1267.611 = 9*230*cos(0.5235987755982)/sqrt(2).
How to calculate Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed)?
With Current Underground AC (I), Maximum Voltage Underground AC (Vm) & Phase Difference (Φ) we can find Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) using the formula - Power Transmitted = Current Underground AC*Maximum Voltage Underground AC*cos(Phase Difference)/sqrt(2). This formula also uses Cosine (cos), Square Root (sqrt) function(s).
What are the other ways to Calculate Power Transmitted?
Here are the different ways to Calculate Power Transmitted-
  • Power Transmitted=sqrt(Area of Underground AC Wire*Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2/(4*Resistivity*Length of Underground AC Wire))OpenImg
  • Power Transmitted=sqrt(Line Losses/(2*Resistance Underground AC))*(Maximum Voltage Underground AC*cos(Phase Difference)/sqrt(2))OpenImg
Can the Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) be negative?
Yes, the Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed), measured in Power can be negative.
Which unit is used to measure Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed)?
Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Power Transmitted using Load Current (1-Phase 2-Wire Mid-Point Earthed) can be measured.
Copied!