Fx Copy
LaTeX Copy
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work. Check FAQs
P=PlineVm22R1
P - Power Transmitted?Pline - Line Losses?Vm - Maximum Voltage?R1 - Resistance underground DC?

Power Transmitted using Line Losses (DC Three-Wire US) Example

With values
With units
Only example

Here is how the Power Transmitted using Line Losses (DC Three-Wire US) equation looks like with Values.

Here is how the Power Transmitted using Line Losses (DC Three-Wire US) equation looks like with Units.

Here is how the Power Transmitted using Line Losses (DC Three-Wire US) equation looks like.

14.6969Edit=0.6Edit60Edit225Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Power Transmitted using Line Losses (DC Three-Wire US)

Power Transmitted using Line Losses (DC Three-Wire US) Solution

Follow our step by step solution on how to calculate Power Transmitted using Line Losses (DC Three-Wire US)?

FIRST Step Consider the formula
P=PlineVm22R1
Next Step Substitute values of Variables
P=0.6W60V225Ω
Next Step Prepare to Evaluate
P=0.660225
Next Step Evaluate
P=14.6969384566991W
LAST Step Rounding Answer
P=14.6969W

Power Transmitted using Line Losses (DC Three-Wire US) Formula Elements

Variables
Functions
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the losses that are produced in the line.
Symbol: Pline
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage
Maximum Voltage the highest voltage rating for electrical devices.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Resistance underground DC
Resistance underground DC is defined as the time rate of flow of charge through a cross-sectional area.
Symbol: R1
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Power Transmitted

​Go Transmitted Power using Volume of Conductor Material(DC Three-Wire US)
P=PlineVVm25ρ(l)2
​Go Power Transmitted using Area of X-Section (DC Three-Wire US)
P=APlineVm22ρl

Other formulas in Resistance, Resistivity and Power category

​Go Resistance using Line Losses (DC Three-Wire US)
R1=Pline2(C12)
​Go Resistivity using Volume of Conductor Material(DC Three-Wire US)
ρ=VPlineVm25(Pl)2
​Go Resistivity using Area of X-Section (DC Three-Wire US)
ρ=APlineVm22l(P2)
​Go Resistivity using Line Losses (DC Three-Wire US)
ρ=APline2l(C12)

How to Evaluate Power Transmitted using Line Losses (DC Three-Wire US)?

Power Transmitted using Line Losses (DC Three-Wire US) evaluator uses Power Transmitted = sqrt(Line Losses*(Maximum Voltage^2)/(2*Resistance underground DC)) to evaluate the Power Transmitted, The Power Transmitted using Line Losses (DC Three-Wire US) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations. Power Transmitted is denoted by P symbol.

How to evaluate Power Transmitted using Line Losses (DC Three-Wire US) using this online evaluator? To use this online evaluator for Power Transmitted using Line Losses (DC Three-Wire US), enter Line Losses (Pline), Maximum Voltage (Vm) & Resistance underground DC (R1) and hit the calculate button.

FAQs on Power Transmitted using Line Losses (DC Three-Wire US)

What is the formula to find Power Transmitted using Line Losses (DC Three-Wire US)?
The formula of Power Transmitted using Line Losses (DC Three-Wire US) is expressed as Power Transmitted = sqrt(Line Losses*(Maximum Voltage^2)/(2*Resistance underground DC)). Here is an example- 14.69694 = sqrt(0.6*(60^2)/(2*5)).
How to calculate Power Transmitted using Line Losses (DC Three-Wire US)?
With Line Losses (Pline), Maximum Voltage (Vm) & Resistance underground DC (R1) we can find Power Transmitted using Line Losses (DC Three-Wire US) using the formula - Power Transmitted = sqrt(Line Losses*(Maximum Voltage^2)/(2*Resistance underground DC)). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Power Transmitted?
Here are the different ways to Calculate Power Transmitted-
  • Power Transmitted=sqrt(Line Losses*Volume Of Conductor*(Maximum Voltage^2)/(5*Resistivity*(Length of Wire DC)^2))OpenImg
  • Power Transmitted=sqrt(Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*Length of Wire DC))OpenImg
Can the Power Transmitted using Line Losses (DC Three-Wire US) be negative?
No, the Power Transmitted using Line Losses (DC Three-Wire US), measured in Power cannot be negative.
Which unit is used to measure Power Transmitted using Line Losses (DC Three-Wire US)?
Power Transmitted using Line Losses (DC Three-Wire US) is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Power Transmitted using Line Losses (DC Three-Wire US) can be measured.
Copied!