Fx Copy
LaTeX Copy
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end. Check FAQs
P=A(Vm2)Ploss((cos(Φ))2)ρL
P - Power Transmitted?A - Area of Overhead AC Wire?Vm - Maximum Voltage Overhead AC?Ploss - Line Losses?Φ - Phase Difference?ρ - Resistivity?L - Length of Overhead AC Wire?

Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) Example

With values
With units
Only example

Here is how the Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) equation looks like with Values.

Here is how the Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) equation looks like with Units.

Here is how the Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) equation looks like.

10184.6168Edit=0.79Edit(62Edit2)8.23Edit((cos(30Edit))2)1.7E-5Edit10.63Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS)

Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) Solution

Follow our step by step solution on how to calculate Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS)?

FIRST Step Consider the formula
P=A(Vm2)Ploss((cos(Φ))2)ρL
Next Step Substitute values of Variables
P=0.79(62V2)8.23W((cos(30°))2)1.7E-5Ω*m10.63m
Next Step Convert Units
P=0.79(62V2)8.23W((cos(0.5236rad))2)1.7E-5Ω*m10.63m
Next Step Prepare to Evaluate
P=0.79(622)8.23((cos(0.5236))2)1.7E-510.63
Next Step Evaluate
P=10184.616761135W
LAST Step Rounding Answer
P=10184.6168W

Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) Formula Elements

Variables
Functions
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Area of Overhead AC Wire
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Maximum Voltage Overhead AC
Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Power Transmitted

​Go Power Transmitted using Load Current (Single-Phase Three-Wire OS)
P=IVmcos(Φ)2
​Go Power Transmitted using Line Losses (Single-Phase Three-Wire OS)
P=PlossA(Vmcos(Φ))2ρL

Other formulas in Power and Power Factor category

​Go Power Factor using Area of X-Section(Single-Phase Three-Wire OS)
PF=(P2)ρLAPloss(Vm2)
​Go Power Factor using Load Current (Single-Phase Three-Wire OS)
PF=PΦVmI

How to Evaluate Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS)?

Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) evaluator uses Power Transmitted = sqrt((Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2))/(Resistivity*Length of Overhead AC Wire)) to evaluate the Power Transmitted, The Power Transmitted using Area of X-section(single-phase three-wire OS) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations. Power Transmitted is denoted by P symbol.

How to evaluate Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) using this online evaluator? To use this online evaluator for Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS), enter Area of Overhead AC Wire (A), Maximum Voltage Overhead AC (Vm), Line Losses (Ploss), Phase Difference (Φ), Resistivity (ρ) & Length of Overhead AC Wire (L) and hit the calculate button.

FAQs on Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS)

What is the formula to find Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS)?
The formula of Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) is expressed as Power Transmitted = sqrt((Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2))/(Resistivity*Length of Overhead AC Wire)). Here is an example- 10184.62 = sqrt((0.79*(62^2)*8.23*((cos(0.5235987755982))^2))/(1.7E-05*10.63)).
How to calculate Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS)?
With Area of Overhead AC Wire (A), Maximum Voltage Overhead AC (Vm), Line Losses (Ploss), Phase Difference (Φ), Resistivity (ρ) & Length of Overhead AC Wire (L) we can find Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) using the formula - Power Transmitted = sqrt((Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2))/(Resistivity*Length of Overhead AC Wire)). This formula also uses Cosine (cos), Square Root (sqrt) function(s).
What are the other ways to Calculate Power Transmitted?
Here are the different ways to Calculate Power Transmitted-
  • Power Transmitted=Current Overhead AC*Maximum Voltage Overhead AC*cos(Phase Difference)*sqrt(2)OpenImg
  • Power Transmitted=sqrt(Line Losses*Area of Overhead AC Wire*(Maximum Voltage Overhead AC*cos(Phase Difference))^2/(Resistivity*Length of Overhead AC Wire))OpenImg
  • Power Transmitted=sqrt(Line Losses*Volume of Conductor*(Maximum Voltage Overhead AC*cos(Phase Difference))^2/(2.5*Resistivity*(Length of Overhead AC Wire)^2))OpenImg
Can the Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) be negative?
No, the Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS), measured in Power cannot be negative.
Which unit is used to measure Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS)?
Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS) can be measured.
Copied!