Fx Copy
LaTeX Copy
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end. Check FAQs
P=(0.5)Pt
P - Power Transmitted?Pt - Power Transmitted per Phase?

Power Transmitted(2-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Power Transmitted(2-Phase 4-Wire OS) equation looks like with Values.

Here is how the Power Transmitted(2-Phase 4-Wire OS) equation looks like with Units.

Here is how the Power Transmitted(2-Phase 4-Wire OS) equation looks like.

124Edit=(0.5)248Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Power Transmitted(2-Phase 4-Wire OS)

Power Transmitted(2-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Power Transmitted(2-Phase 4-Wire OS)?

FIRST Step Consider the formula
P=(0.5)Pt
Next Step Substitute values of Variables
P=(0.5)248W
Next Step Prepare to Evaluate
P=(0.5)248
LAST Step Evaluate
P=124W

Power Transmitted(2-Phase 4-Wire OS) Formula Elements

Variables
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Power Transmitted per Phase
Power Transmitted per Phase is defined as the power delivered to a single phase in a poly-phase electrical network.
Symbol: Pt
Measurement: PowerUnit: W
Note: Value should be greater than 0.

Other Formulas to find Power Transmitted

​Go Power Transmitted using Area of X-Section(2-Phase 4-Wire OS)
P=2A(Vm2)Ploss((cos(Φ))2)ρL
​Go Power Transmitted using Load Current (2-Phase 4-Wire OS)
P=IVmcos(Φ)2(2)
​Go Power Transmitted using Line Losses (2-Phase 4-Wire OS)
P=2PlossA(Vmcos(Φ))2ρL

Other formulas in Power and Power Factor category

​Go Power Factor using Area of X-Section(2-Phase 4-Wire OS)
PF=(P2)ρL2APloss(Vm2)
​Go Power Factor using Load Current (2-Phase 4-Wire OS)
PF=P22VmI
​Go Power Factor using Line Losses (2-Phase 4-Wire OS)
PF=(PVm)ρL2PlossA

How to Evaluate Power Transmitted(2-Phase 4-Wire OS)?

Power Transmitted(2-Phase 4-Wire OS) evaluator uses Power Transmitted = (0.5)*Power Transmitted per Phase to evaluate the Power Transmitted, The Power Transmitted(2-Phase 4-Wire OS) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations. Power Transmitted is denoted by P symbol.

How to evaluate Power Transmitted(2-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Power Transmitted(2-Phase 4-Wire OS), enter Power Transmitted per Phase (Pt) and hit the calculate button.

FAQs on Power Transmitted(2-Phase 4-Wire OS)

What is the formula to find Power Transmitted(2-Phase 4-Wire OS)?
The formula of Power Transmitted(2-Phase 4-Wire OS) is expressed as Power Transmitted = (0.5)*Power Transmitted per Phase. Here is an example- 124 = (0.5)*248.
How to calculate Power Transmitted(2-Phase 4-Wire OS)?
With Power Transmitted per Phase (Pt) we can find Power Transmitted(2-Phase 4-Wire OS) using the formula - Power Transmitted = (0.5)*Power Transmitted per Phase.
What are the other ways to Calculate Power Transmitted?
Here are the different ways to Calculate Power Transmitted-
  • Power Transmitted=sqrt((2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2))/(Resistivity*Length of Overhead AC Wire))OpenImg
  • Power Transmitted=Current Overhead AC*Maximum Voltage Overhead AC*cos(Phase Difference)*2*(sqrt(2))OpenImg
  • Power Transmitted=sqrt(2*Line Losses*Area of Overhead AC Wire*(Maximum Voltage Overhead AC*cos(Phase Difference))^2/(Resistivity*Length of Overhead AC Wire))OpenImg
Can the Power Transmitted(2-Phase 4-Wire OS) be negative?
No, the Power Transmitted(2-Phase 4-Wire OS), measured in Power cannot be negative.
Which unit is used to measure Power Transmitted(2-Phase 4-Wire OS)?
Power Transmitted(2-Phase 4-Wire OS) is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Power Transmitted(2-Phase 4-Wire OS) can be measured.
Copied!