Power Supply during Charging Formula

Fx Copy
LaTeX Copy
Voltage of power supply for edm, is the voltage required to charge a given device within given time. Check FAQs
Vcc=Rccicexp(-tcc𝜏cc)
Vcc - Voltage of Power Supply for EDM?Rcc - Resistance of the Charging Circuit for EDM?ic - Charging Current at any Time for EDM?tcc - Time Elapsed for EDM?𝜏cc - Time Constant for EDM?

Power Supply during Charging Example

With values
With units
Only example

Here is how the Power Supply during Charging equation looks like with Values.

Here is how the Power Supply during Charging equation looks like with Units.

Here is how the Power Supply during Charging equation looks like.

1.2Edit=0.18Edit6.1Editexp(-8.88Edit100Edit)
You are here -
HomeIcon Home » Category Engineering » Category Production Engineering » Category Unconventional machining processes » fx Power Supply during Charging

Power Supply during Charging Solution

Follow our step by step solution on how to calculate Power Supply during Charging?

FIRST Step Consider the formula
Vcc=Rccicexp(-tcc𝜏cc)
Next Step Substitute values of Variables
Vcc=0.18Ω6.1Aexp(-8.88s100s)
Next Step Prepare to Evaluate
Vcc=0.186.1exp(-8.88100)
Next Step Evaluate
Vcc=1.19996254413663V
LAST Step Rounding Answer
Vcc=1.2V

Power Supply during Charging Formula Elements

Variables
Functions
Voltage of Power Supply for EDM
Voltage of power supply for edm, is the voltage required to charge a given device within given time.
Symbol: Vcc
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Resistance of the Charging Circuit for EDM
Resistance of the charging circuit for edm, is the resistance of the charging circuit.
Symbol: Rcc
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Charging Current at any Time for EDM
Charging current at any time for edm (t) is the current at any given instance of time.
Symbol: ic
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Time Elapsed for EDM
Time elapsed for edm, time elapsed after a particular task is started.
Symbol: tcc
Measurement: TimeUnit: s
Note: Value should be greater than 0.
Time Constant for EDM
Time Constant for edm, of the response represents the elapsed time required for the system response to decay to zero if the system had continued to decay at the initial rate.
Symbol: 𝜏cc
Measurement: TimeUnit: s
Note: Value should be greater than 0.
exp
n an exponential function, the value of the function changes by a constant factor for every unit change in the independent variable.
Syntax: exp(Number)

Other formulas in Charging Current for EDM category

​Go Charging Current in Relaxation Circuit
ic=VccRccexp(-tcc𝜏cc)
​Go Resistance of Charging Circuit
Rcc=Vccexp(-tcc𝜏cc)ic
​Go Time Elapsed during Charging
tcc=-𝜏ccln(icRccVcc)
​Go Time Constant from Charging Current
𝜏cc=-tccln(icRccVcc)

How to Evaluate Power Supply during Charging?

Power Supply during Charging evaluator uses Voltage of Power Supply for EDM = (Resistance of the Charging Circuit for EDM*Charging Current at any Time for EDM)/(exp(-Time Elapsed for EDM/Time Constant for EDM)) to evaluate the Voltage of Power Supply for EDM, The Power supply during charging formula is defined as the voltage of power supply used to charge the relaxation circuit used to provide spark in unconventional EDM. Voltage of Power Supply for EDM is denoted by Vcc symbol.

How to evaluate Power Supply during Charging using this online evaluator? To use this online evaluator for Power Supply during Charging, enter Resistance of the Charging Circuit for EDM (Rcc), Charging Current at any Time for EDM (ic), Time Elapsed for EDM (tcc) & Time Constant for EDM (𝜏cc) and hit the calculate button.

FAQs on Power Supply during Charging

What is the formula to find Power Supply during Charging?
The formula of Power Supply during Charging is expressed as Voltage of Power Supply for EDM = (Resistance of the Charging Circuit for EDM*Charging Current at any Time for EDM)/(exp(-Time Elapsed for EDM/Time Constant for EDM)). Here is an example- 1.573721 = (0.18*6.1)/(exp(-8.88/100)).
How to calculate Power Supply during Charging?
With Resistance of the Charging Circuit for EDM (Rcc), Charging Current at any Time for EDM (ic), Time Elapsed for EDM (tcc) & Time Constant for EDM (𝜏cc) we can find Power Supply during Charging using the formula - Voltage of Power Supply for EDM = (Resistance of the Charging Circuit for EDM*Charging Current at any Time for EDM)/(exp(-Time Elapsed for EDM/Time Constant for EDM)). This formula also uses Exponential Growth Function function(s).
Can the Power Supply during Charging be negative?
No, the Power Supply during Charging, measured in Electric Potential cannot be negative.
Which unit is used to measure Power Supply during Charging?
Power Supply during Charging is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Power Supply during Charging can be measured.
Copied!