Power gain of down converter given Degradation Factor Formula

Fx Copy
LaTeX Copy
Power gain of down converter given Gain degradation factor is a measure of how much the input power is increased or decreased as a result of the down conversion process. Check FAQs
Gaindc=fsfofsfo(γQ)2(1+1+(fsfo(γQ)2))2
Gaindc - Power gain of down converter?fs - Signal Frequency?fo - Output Frequency?γQ - Figure of Merit?

Power gain of down converter given Degradation Factor Example

With values
With units
Only example

Here is how the Power gain of down converter given Degradation Factor equation looks like with Values.

Here is how the Power gain of down converter given Degradation Factor equation looks like with Units.

Here is how the Power gain of down converter given Degradation Factor equation looks like.

0.7646Edit=28Edit26Edit28Edit26Edit(5.6Edit)2(1+1+(28Edit26Edit(5.6Edit)2))2
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Microwave Theory » fx Power gain of down converter given Degradation Factor

Power gain of down converter given Degradation Factor Solution

Follow our step by step solution on how to calculate Power gain of down converter given Degradation Factor?

FIRST Step Consider the formula
Gaindc=fsfofsfo(γQ)2(1+1+(fsfo(γQ)2))2
Next Step Substitute values of Variables
Gaindc=28Hz26Hz28Hz26Hz(5.6)2(1+1+(28Hz26Hz(5.6)2))2
Next Step Prepare to Evaluate
Gaindc=28262826(5.6)2(1+1+(2826(5.6)2))2
Next Step Evaluate
Gaindc=0.764626847874621W
LAST Step Rounding Answer
Gaindc=0.7646W

Power gain of down converter given Degradation Factor Formula Elements

Variables
Functions
Power gain of down converter
Power gain of down converter given Gain degradation factor is a measure of how much the input power is increased or decreased as a result of the down conversion process.
Symbol: Gaindc
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Signal Frequency
Signal Frequency refer to the frequency of an electrical waveform, such as an alternating current (AC) signal.
Symbol: fs
Measurement: FrequencyUnit: Hz
Note: Value should be greater than 0.
Output Frequency
Output Frequency refers to the rate at which a system or device produces outputs or results.
Symbol: fo
Measurement: FrequencyUnit: Hz
Note: Value should be greater than 0.
Figure of Merit
Figure of Merit is a measure used to quantify the performance of a device, system.
Symbol: γQ
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Transistor Amplifiers category

​Go MESFET Cutoff Frequency
fco=Gm2πCgs
​Go Maximum Operating Frequency
fmax=fco2RdRs+Ri+Rg
​Go Transconductance in Saturation Region in MESFET
Gm=g0(1-Vi-VGVp)
​Go Maximum Frequency of Oscillation
fmax o=vs2πLc

How to Evaluate Power gain of down converter given Degradation Factor?

Power gain of down converter given Degradation Factor evaluator uses Power gain of down converter = Signal Frequency/Output Frequency*(Signal Frequency/Output Frequency*(Figure of Merit)^2)/(1+sqrt(1+(Signal Frequency/Output Frequency*(Figure of Merit)^2)))^2 to evaluate the Power gain of down converter, The Power gain of down converter given Degradation Factor formula is defined as a device that takes an incoming signal at a higher frequency and converts it to a lower frequency. Power gain of down converter is denoted by Gaindc symbol.

How to evaluate Power gain of down converter given Degradation Factor using this online evaluator? To use this online evaluator for Power gain of down converter given Degradation Factor, enter Signal Frequency (fs), Output Frequency (fo) & Figure of Merit (γQ) and hit the calculate button.

FAQs on Power gain of down converter given Degradation Factor

What is the formula to find Power gain of down converter given Degradation Factor?
The formula of Power gain of down converter given Degradation Factor is expressed as Power gain of down converter = Signal Frequency/Output Frequency*(Signal Frequency/Output Frequency*(Figure of Merit)^2)/(1+sqrt(1+(Signal Frequency/Output Frequency*(Figure of Merit)^2)))^2. Here is an example- 0.764627 = 28/26*(28/26*(5.6)^2)/(1+sqrt(1+(28/26*(5.6)^2)))^2.
How to calculate Power gain of down converter given Degradation Factor?
With Signal Frequency (fs), Output Frequency (fo) & Figure of Merit (γQ) we can find Power gain of down converter given Degradation Factor using the formula - Power gain of down converter = Signal Frequency/Output Frequency*(Signal Frequency/Output Frequency*(Figure of Merit)^2)/(1+sqrt(1+(Signal Frequency/Output Frequency*(Figure of Merit)^2)))^2. This formula also uses Square Root (sqrt) function(s).
Can the Power gain of down converter given Degradation Factor be negative?
No, the Power gain of down converter given Degradation Factor, measured in Power cannot be negative.
Which unit is used to measure Power gain of down converter given Degradation Factor?
Power gain of down converter given Degradation Factor is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Power gain of down converter given Degradation Factor can be measured.
Copied!