Fx Copy
LaTeX Copy
The power factor of an AC electrical power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Check FAQs
PF=(2)KV
PF - Power Factor?K - Constant Underground AC?V - Volume Of Conductor?

Power Factor using Volume of Conductor Material (1-Phase 2-Wire US) Example

With values
With units
Only example

Here is how the Power Factor using Volume of Conductor Material (1-Phase 2-Wire US) equation looks like with Values.

Here is how the Power Factor using Volume of Conductor Material (1-Phase 2-Wire US) equation looks like with Units.

Here is how the Power Factor using Volume of Conductor Material (1-Phase 2-Wire US) equation looks like.

0.1703Edit=(2)0.87Edit60Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Power Factor using Volume of Conductor Material (1-Phase 2-Wire US)

Power Factor using Volume of Conductor Material (1-Phase 2-Wire US) Solution

Follow our step by step solution on how to calculate Power Factor using Volume of Conductor Material (1-Phase 2-Wire US)?

FIRST Step Consider the formula
PF=(2)KV
Next Step Substitute values of Variables
PF=(2)0.8760
Next Step Prepare to Evaluate
PF=(2)0.8760
Next Step Evaluate
PF=0.170293863659264
LAST Step Rounding Answer
PF=0.1703

Power Factor using Volume of Conductor Material (1-Phase 2-Wire US) Formula Elements

Variables
Functions
Power Factor
The power factor of an AC electrical power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit.
Symbol: PF
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Constant Underground AC
Constant Underground AC is defined as the constant of line of a Overhead supply system.
Symbol: K
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Power Factor

​Go Power Factor using Area of X-Section (1-Phase 2-Wire US)
PF=(4)(P2)ρLAPloss(Vm2)
​Go Power Factor using Load Current (1-Phase 2-Wire US)
PF=2PVmI
​Go Power Factor using Line Losses (1-Phase 2-Wire US)
PF=(2PVm)ρLPlossA
​Go Power Factor using Resistance (1-Phase 2-Wire US)
PF=(2PVm)RPloss

Other formulas in Power and Power Factor category

​Go Power Transmitted using Area of X-Section (1-Phase 2-Wire US)
P=A(Vm2)Ploss((cos(Φ))2)4ρL
​Go Power Transmitted using Volume of Conductor Material (1-Phase 2-Wire US)
P=PlossV(Vmcos(Φ))28ρ(L)2
​Go Power Transmitted using Load Current (1-Phase 2-Wire US)
P=IVmcos(Φ)2
​Go Power Transmitted using Line Losses (1-Phase 2-Wire US)
P=PlossA(Vmcos(Φ))24ρL

How to Evaluate Power Factor using Volume of Conductor Material (1-Phase 2-Wire US)?

Power Factor using Volume of Conductor Material (1-Phase 2-Wire US) evaluator uses Power Factor = sqrt((2)*Constant Underground AC/Volume Of Conductor) to evaluate the Power Factor, The Power Factor using Volume of Conductor Material (1-Phase 2-Wire US) formula is defined as the cosine of the angle between the voltage phasor and current phasor in an AC circuit. Power Factor is denoted by PF symbol.

How to evaluate Power Factor using Volume of Conductor Material (1-Phase 2-Wire US) using this online evaluator? To use this online evaluator for Power Factor using Volume of Conductor Material (1-Phase 2-Wire US), enter Constant Underground AC (K) & Volume Of Conductor (V) and hit the calculate button.

FAQs on Power Factor using Volume of Conductor Material (1-Phase 2-Wire US)

What is the formula to find Power Factor using Volume of Conductor Material (1-Phase 2-Wire US)?
The formula of Power Factor using Volume of Conductor Material (1-Phase 2-Wire US) is expressed as Power Factor = sqrt((2)*Constant Underground AC/Volume Of Conductor). Here is an example- 0.170294 = sqrt((2)*0.87/60).
How to calculate Power Factor using Volume of Conductor Material (1-Phase 2-Wire US)?
With Constant Underground AC (K) & Volume Of Conductor (V) we can find Power Factor using Volume of Conductor Material (1-Phase 2-Wire US) using the formula - Power Factor = sqrt((2)*Constant Underground AC/Volume Of Conductor). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Power Factor?
Here are the different ways to Calculate Power Factor-
  • Power Factor=sqrt(((4)*(Power Transmitted^2)*Resistivity*Length of Underground AC Wire)/(Area of Underground AC Wire*Line Losses*(Maximum Voltage Underground AC^2)))OpenImg
  • Power Factor=(sqrt(2)*Power Transmitted)/(Maximum Voltage Underground AC*Current Underground AC)OpenImg
  • Power Factor=(2*Power Transmitted/Maximum Voltage Underground AC)*sqrt(Resistivity*Length of Underground AC Wire/Line Losses*Area of Underground AC Wire)OpenImg
Copied!