Fx Copy
LaTeX Copy
The power factor of an AC electrical power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Check FAQs
PF=P2VmI
PF - Power Factor?P - Power Transmitted?Vm - Maximum Voltage Overhead AC?I - Current Overhead AC?

Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS) Example

With values
With units
Only example

Here is how the Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS) equation looks like with Values.

Here is how the Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS) equation looks like with Units.

Here is how the Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS) equation looks like.

1.4711Edit=890Edit262Edit6.9Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS)

Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS) Solution

Follow our step by step solution on how to calculate Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS)?

FIRST Step Consider the formula
PF=P2VmI
Next Step Substitute values of Variables
PF=890W262V6.9A
Next Step Prepare to Evaluate
PF=8902626.9
Next Step Evaluate
PF=1.4710730136887
LAST Step Rounding Answer
PF=1.4711

Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS) Formula Elements

Variables
Functions
Power Factor
The power factor of an AC electrical power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit.
Symbol: PF
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Maximum Voltage Overhead AC
Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Current Overhead AC
Current Overhead AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Power Factor

​Go Power Factor using Area of X-Section(Single-Phase Two-Wire Mid-Point Earthed OS)
PF=(P2)ρLAPloss(Vm2)
​Go Power Factor using Line Losses (Single-Phase Two-Wire Mid-Point OS)
PF=(PVm)ρLPlossA

Other formulas in Power and Power Factor category

​Go Power Transmitted using Area of X-Section(Single-Phase Two-Wire Mid-Point Earthed OS)
P=A(Vm2)Ploss((cos(Φ))2)ρL
​Go Power Transmitted using Load Current (Single-Phase Two-Wire Mid-Point OS)
P=IVmcos(Φ)2
​Go Power Transmitted using Line Losses (Single-Phase Two-Wire Mid-Point OS)
P=PlossA(Vmcos(Φ))2ρL

How to Evaluate Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS)?

Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS) evaluator uses Power Factor = Power Transmitted/(sqrt(2)*Maximum Voltage Overhead AC*Current Overhead AC) to evaluate the Power Factor, Power Factor using Load Current (single-Phase two-Wire Mid-Point OS) formula is defined as the cosine of the angle between the voltage phasor and current phasor in an AC circuit. Power Factor is denoted by PF symbol.

How to evaluate Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS) using this online evaluator? To use this online evaluator for Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS), enter Power Transmitted (P), Maximum Voltage Overhead AC (Vm) & Current Overhead AC (I) and hit the calculate button.

FAQs on Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS)

What is the formula to find Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS)?
The formula of Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS) is expressed as Power Factor = Power Transmitted/(sqrt(2)*Maximum Voltage Overhead AC*Current Overhead AC). Here is an example- 1.471073 = 890/(sqrt(2)*62*6.9).
How to calculate Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS)?
With Power Transmitted (P), Maximum Voltage Overhead AC (Vm) & Current Overhead AC (I) we can find Power Factor using Load Current (Single-Phase Two-Wire Mid-Point OS) using the formula - Power Factor = Power Transmitted/(sqrt(2)*Maximum Voltage Overhead AC*Current Overhead AC). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Power Factor?
Here are the different ways to Calculate Power Factor-
  • Power Factor=sqrt(((Power Transmitted^2)*Resistivity*Length of Overhead AC Wire)/(Area of Overhead AC Wire*Line Losses*(Maximum Voltage Overhead AC^2)))OpenImg
  • Power Factor=(Power Transmitted/Maximum Voltage Overhead AC)*sqrt((Resistivity*Length of Overhead AC Wire)/(Line Losses*Area of Overhead AC Wire))OpenImg
Copied!