The power factor of an AC electrical power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Check FAQs
PF=PIVm
PF - Power Factor?P - Power Transmitted?I - Current Underground AC?Vm - Maximum Voltage Underground AC?

Power Factor using Current in Each Outer (2-Phase 3-Wire US) Example

With values
With units
Only example

Here is how the Power Factor using Current in Each Outer (2-Phase 3-Wire US) equation looks like with Values.

Here is how the Power Factor using Current in Each Outer (2-Phase 3-Wire US) equation looks like with Units.

Here is how the Power Factor using Current in Each Outer (2-Phase 3-Wire US) equation looks like.

0.1449Edit=300Edit9Edit230Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Power Factor using Current in Each Outer (2-Phase 3-Wire US)

Power Factor using Current in Each Outer (2-Phase 3-Wire US) Solution

Follow our step by step solution on how to calculate Power Factor using Current in Each Outer (2-Phase 3-Wire US)?

FIRST Step Consider the formula
PF=PIVm
Next Step Substitute values of Variables
PF=300W9A230V
Next Step Prepare to Evaluate
PF=3009230
Next Step Evaluate
PF=0.144927536231884
LAST Step Rounding Answer
PF=0.1449

Power Factor using Current in Each Outer (2-Phase 3-Wire US) Formula Elements

Variables
Power Factor
The power factor of an AC electrical power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit.
Symbol: PF
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Maximum Voltage Underground AC
Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.

Other Formulas to find Power Factor

​Go Power Factor using Volume of Conductor Material (2 Phase 3 Wire US)
PF=(2.194)KV
​Go Power Factor using Line Losses (2-Phase 3-Wire US)
PF=(PVm)(2+2)ρLPlossA
​Go Power Factor using Current in Neutral Wire (2-Phase 3-Wire US)
PF=2PIVm

Other formulas in Power and Power Factor category

​Go Power Transmitted using Volume of Conductor Material (2 Phase 3 Wire US)
P=PlossV(Vmcos(Φ))2ρ(((2+2)L)2)
​Go Transmitted Power using Line Losses (2-Phase 3-Wire US)
P=PlossA(Vmcos(Φ))2(2+2)ρL
​Go Power Transmitted using Current in Each Outer (2-Phase 3-Wire US)
P=IVmcos(Φ)
​Go Power Transmitted using Current in Neutral Wire (2-Phase 3-Wire US)
P=IVmcos(Φ)2

How to Evaluate Power Factor using Current in Each Outer (2-Phase 3-Wire US)?

Power Factor using Current in Each Outer (2-Phase 3-Wire US) evaluator uses Power Factor = Power Transmitted/(Current Underground AC*Maximum Voltage Underground AC) to evaluate the Power Factor, The Power Factor using Current in Each Outer (2-Phase 3-Wire US) formula is defined as the cosine of the angle between the voltage phasor and current phasor in an AC circuit. Power Factor is denoted by PF symbol.

How to evaluate Power Factor using Current in Each Outer (2-Phase 3-Wire US) using this online evaluator? To use this online evaluator for Power Factor using Current in Each Outer (2-Phase 3-Wire US), enter Power Transmitted (P), Current Underground AC (I) & Maximum Voltage Underground AC (Vm) and hit the calculate button.

FAQs on Power Factor using Current in Each Outer (2-Phase 3-Wire US)

What is the formula to find Power Factor using Current in Each Outer (2-Phase 3-Wire US)?
The formula of Power Factor using Current in Each Outer (2-Phase 3-Wire US) is expressed as Power Factor = Power Transmitted/(Current Underground AC*Maximum Voltage Underground AC). Here is an example- 0.144928 = 300/(9*230).
How to calculate Power Factor using Current in Each Outer (2-Phase 3-Wire US)?
With Power Transmitted (P), Current Underground AC (I) & Maximum Voltage Underground AC (Vm) we can find Power Factor using Current in Each Outer (2-Phase 3-Wire US) using the formula - Power Factor = Power Transmitted/(Current Underground AC*Maximum Voltage Underground AC).
What are the other ways to Calculate Power Factor?
Here are the different ways to Calculate Power Factor-
  • Power Factor=sqrt((2.194)*Constant Underground AC/Volume Of Conductor)OpenImg
  • Power Factor=(Power Transmitted/Maximum Voltage Underground AC)*sqrt((2+sqrt(2))*Resistivity*Length of Underground AC Wire/Line Losses*Area of Underground AC Wire)OpenImg
  • Power Factor=sqrt(2)*Power Transmitted/(Current Underground AC*Maximum Voltage Underground AC)OpenImg
Copied!