The power factor of an AC electrical power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Check FAQs
PF=(PVm)2ρL3A
PF - Power Factor?P - Power Transmitted?Vm - Maximum Voltage Overhead AC?ρ - Resistivity?L - Length of Overhead AC Wire?A - Area of Overhead AC Wire?

Power Factor using Area of X-Section(3-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Power Factor using Area of X-Section(3-Phase 4-Wire OS) equation looks like with Values.

Here is how the Power Factor using Area of X-Section(3-Phase 4-Wire OS) equation looks like with Units.

Here is how the Power Factor using Area of X-Section(3-Phase 4-Wire OS) equation looks like.

0.1773Edit=(890Edit62Edit)21.7E-5Edit10.63Edit30.79Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Power Factor using Area of X-Section(3-Phase 4-Wire OS)

Power Factor using Area of X-Section(3-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Power Factor using Area of X-Section(3-Phase 4-Wire OS)?

FIRST Step Consider the formula
PF=(PVm)2ρL3A
Next Step Substitute values of Variables
PF=(890W62V)21.7E-5Ω*m10.63m30.79
Next Step Prepare to Evaluate
PF=(89062)21.7E-510.6330.79
Next Step Evaluate
PF=0.177267955125567
LAST Step Rounding Answer
PF=0.1773

Power Factor using Area of X-Section(3-Phase 4-Wire OS) Formula Elements

Variables
Functions
Power Factor
The power factor of an AC electrical power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit.
Symbol: PF
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Maximum Voltage Overhead AC
Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Area of Overhead AC Wire
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Power Factor

​Go Power Factor using Volume of Conductor Material (3-Phase 4-Wire OS)
PF=(0.583)KV
​Go Power Factor using Load Current (3-Phase 4-Wire OS)
PF=2P3Vm

Other formulas in Power and Power Factor category

​Go Power Transmitted(3-Phase 4-Wire OS)
P=(13)Pt
​Go Power Transmitted using Area of X-Section(3-Phase 4-Wire OS)
P=3A(Vm2)Ploss((cos(Φ))2)ρ2L
​Go Power Transmitted using Volume of Conductor Material (3-Phase 4-Wire OS)
P=3PlossV(Vmcos(Φ))27ρ(L)2
​Go Angle of PF using Volume of Conductor Material (3-Phase 4-Wire OS)
Φ=acos((0.583)KV)

How to Evaluate Power Factor using Area of X-Section(3-Phase 4-Wire OS)?

Power Factor using Area of X-Section(3-Phase 4-Wire OS) evaluator uses Power Factor = (Power Transmitted/Maximum Voltage Overhead AC)*sqrt(2*Resistivity*Length of Overhead AC Wire/(3*Area of Overhead AC Wire)) to evaluate the Power Factor, The Power Factor using Area of X-section(3-phase 4-wire OS) formula is defined as the cosine of the angle between the voltage phasor and current phasor in an AC circuit. Power Factor is denoted by PF symbol.

How to evaluate Power Factor using Area of X-Section(3-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Power Factor using Area of X-Section(3-Phase 4-Wire OS), enter Power Transmitted (P), Maximum Voltage Overhead AC (Vm), Resistivity (ρ), Length of Overhead AC Wire (L) & Area of Overhead AC Wire (A) and hit the calculate button.

FAQs on Power Factor using Area of X-Section(3-Phase 4-Wire OS)

What is the formula to find Power Factor using Area of X-Section(3-Phase 4-Wire OS)?
The formula of Power Factor using Area of X-Section(3-Phase 4-Wire OS) is expressed as Power Factor = (Power Transmitted/Maximum Voltage Overhead AC)*sqrt(2*Resistivity*Length of Overhead AC Wire/(3*Area of Overhead AC Wire)). Here is an example- 0.177268 = (890/62)*sqrt(2*1.7E-05*10.63/(3*0.79)).
How to calculate Power Factor using Area of X-Section(3-Phase 4-Wire OS)?
With Power Transmitted (P), Maximum Voltage Overhead AC (Vm), Resistivity (ρ), Length of Overhead AC Wire (L) & Area of Overhead AC Wire (A) we can find Power Factor using Area of X-Section(3-Phase 4-Wire OS) using the formula - Power Factor = (Power Transmitted/Maximum Voltage Overhead AC)*sqrt(2*Resistivity*Length of Overhead AC Wire/(3*Area of Overhead AC Wire)). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Power Factor?
Here are the different ways to Calculate Power Factor-
  • Power Factor=sqrt((0.583)*Constant Overhead AC/Volume of Conductor)OpenImg
  • Power Factor=(sqrt(2)*Power Transmitted)/(3*Maximum Voltage Overhead AC)OpenImg
Copied!