Power Extracted by Rotor given Power Coefficient of Wind Machine Formula

Fx Copy
LaTeX Copy
Power Extracted by Rotor is the rate at which mechanical energy is extracted by the rotor from the wind stream by reducing its kinetic energy. Check FAQs
Pe=Cp(0.5ρπ(R2)V3)
Pe - Power Extracted by Rotor?Cp - Power Coefficient of Wind Machine?ρ - Density of Air?R - Rotor Radius?V - Free Stream Wind Speed?π - Archimedes' constant?

Power Extracted by Rotor given Power Coefficient of Wind Machine Example

With values
With units
Only example

Here is how the Power Extracted by Rotor given Power Coefficient of Wind Machine equation looks like with Values.

Here is how the Power Extracted by Rotor given Power Coefficient of Wind Machine equation looks like with Units.

Here is how the Power Extracted by Rotor given Power Coefficient of Wind Machine equation looks like.

39.8084Edit=0.4Edit(0.51.293Edit3.1416(7Edit2)10Edit3)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Solar Energy Systems » fx Power Extracted by Rotor given Power Coefficient of Wind Machine

Power Extracted by Rotor given Power Coefficient of Wind Machine Solution

Follow our step by step solution on how to calculate Power Extracted by Rotor given Power Coefficient of Wind Machine?

FIRST Step Consider the formula
Pe=Cp(0.5ρπ(R2)V3)
Next Step Substitute values of Variables
Pe=0.4(0.51.293kg/m³π(7m2)10m/s3)
Next Step Substitute values of Constants
Pe=0.4(0.51.293kg/m³3.1416(7m2)10m/s3)
Next Step Prepare to Evaluate
Pe=0.4(0.51.2933.1416(72)103)
Next Step Evaluate
Pe=39808.3771506977W
Next Step Convert to Output's Unit
Pe=39.8083771506977kW
LAST Step Rounding Answer
Pe=39.8084kW

Power Extracted by Rotor given Power Coefficient of Wind Machine Formula Elements

Variables
Constants
Power Extracted by Rotor
Power Extracted by Rotor is the rate at which mechanical energy is extracted by the rotor from the wind stream by reducing its kinetic energy.
Symbol: Pe
Measurement: PowerUnit: kW
Note: Value should be greater than 0.
Power Coefficient of Wind Machine
Power Coefficient of Wind Machine is defined as the ratio of the power extracted by the rotor to the power available in the wind stream.
Symbol: Cp
Measurement: NAUnit: Unitless
Note: Value should be between 0 to 0.6.
Density of Air
Density of Air is the mass of air per unit volume; it decreases with altitude due to lower pressure.
Symbol: ρ
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.
Rotor Radius
Rotor Radius is the radius of rotation of the rotor.
Symbol: R
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Free Stream Wind Speed
Free Stream Wind Speed is the velocity of the free stream which is the air far upstream of an aerodynamic body i.e. before the body has a chance to deflect, slow down or compress the air.
Symbol: V
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Other Renewable Energy Sources category

​Go Power Coefficient of Wind Machine
Cp=Pe0.5ρπR2V3
​Go Lift Coefficient of Blade of Wind Rotor
CL=L0.5ρvcπR2V2
​Go Lift Force given Lift Coefficient of Blade
L=CL0.5ρvcπR2V2
​Go Drag Coefficient of Blade of Wind Rotor
CD=FD0.5ρvcπR2V2

How to Evaluate Power Extracted by Rotor given Power Coefficient of Wind Machine?

Power Extracted by Rotor given Power Coefficient of Wind Machine evaluator uses Power Extracted by Rotor = Power Coefficient of Wind Machine*(0.5*Density of Air*pi*(Rotor Radius^2)*Free Stream Wind Speed^3) to evaluate the Power Extracted by Rotor, The Power Extracted by Rotor given Power Coefficient of Wind Machine is defined as the rate at which mechanical energy is extracted by the rotor from the wind stream by reducing its kinetic energy. Power Extracted by Rotor is denoted by Pe symbol.

How to evaluate Power Extracted by Rotor given Power Coefficient of Wind Machine using this online evaluator? To use this online evaluator for Power Extracted by Rotor given Power Coefficient of Wind Machine, enter Power Coefficient of Wind Machine (Cp), Density of Air (ρ), Rotor Radius (R) & Free Stream Wind Speed (V) and hit the calculate button.

FAQs on Power Extracted by Rotor given Power Coefficient of Wind Machine

What is the formula to find Power Extracted by Rotor given Power Coefficient of Wind Machine?
The formula of Power Extracted by Rotor given Power Coefficient of Wind Machine is expressed as Power Extracted by Rotor = Power Coefficient of Wind Machine*(0.5*Density of Air*pi*(Rotor Radius^2)*Free Stream Wind Speed^3). Here is an example- 0.039808 = 0.4*(0.5*1.293*pi*(7^2)*10^3).
How to calculate Power Extracted by Rotor given Power Coefficient of Wind Machine?
With Power Coefficient of Wind Machine (Cp), Density of Air (ρ), Rotor Radius (R) & Free Stream Wind Speed (V) we can find Power Extracted by Rotor given Power Coefficient of Wind Machine using the formula - Power Extracted by Rotor = Power Coefficient of Wind Machine*(0.5*Density of Air*pi*(Rotor Radius^2)*Free Stream Wind Speed^3). This formula also uses Archimedes' constant .
Can the Power Extracted by Rotor given Power Coefficient of Wind Machine be negative?
No, the Power Extracted by Rotor given Power Coefficient of Wind Machine, measured in Power cannot be negative.
Which unit is used to measure Power Extracted by Rotor given Power Coefficient of Wind Machine?
Power Extracted by Rotor given Power Coefficient of Wind Machine is usually measured using the Kilowatt[kW] for Power. Watt[kW], Milliwatt[kW], Microwatt[kW] are the few other units in which Power Extracted by Rotor given Power Coefficient of Wind Machine can be measured.
Copied!