Power Delivered to Load in Three Phase Uncontrolled Rectifier Formula

Fx Copy
LaTeX Copy
Delivery Power to Load of an uncontrolled rectifier is the product of the average load voltage and the average load current. Check FAQs
Pout=VacVdc
Pout - Delivery Power?Vac - AC Voltage?Vdc - Average Output Voltage?

Power Delivered to Load in Three Phase Uncontrolled Rectifier Example

With values
With units
Only example

Here is how the Power Delivered to Load in Three Phase Uncontrolled Rectifier equation looks like with Values.

Here is how the Power Delivered to Load in Three Phase Uncontrolled Rectifier equation looks like with Units.

Here is how the Power Delivered to Load in Three Phase Uncontrolled Rectifier equation looks like.

230882.8655Edit=2100.845Edit109.9Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Power Delivered to Load in Three Phase Uncontrolled Rectifier

Power Delivered to Load in Three Phase Uncontrolled Rectifier Solution

Follow our step by step solution on how to calculate Power Delivered to Load in Three Phase Uncontrolled Rectifier?

FIRST Step Consider the formula
Pout=VacVdc
Next Step Substitute values of Variables
Pout=2100.845V109.9V
Next Step Prepare to Evaluate
Pout=2100.845109.9
LAST Step Evaluate
Pout=230882.8655W

Power Delivered to Load in Three Phase Uncontrolled Rectifier Formula Elements

Variables
Delivery Power
Delivery Power to Load of an uncontrolled rectifier is the product of the average load voltage and the average load current.
Symbol: Pout
Measurement: PowerUnit: W
Note: Value should be greater than 0.
AC Voltage
AC Voltage uncontrolled rectifier is also known as the DC output voltage. It is the voltage that is available to the load circuit.
Symbol: Vac
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Average Output Voltage
Average Output Voltage is the average dc value of the output voltage.
Symbol: Vdc
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other formulas in Full Wave category

​Go Load Voltage of Full Wave Three Phase Uncontrolled Rectifier
Vac=2nVmaxπ
​Go Average Load Current of Three Phase Uncontrolled Rectifier
IL(avg)=33nVmax2πRL
​Go RMS Load Current of Three Phase Uncontrolled Rectifier
IL(rms)=nVmaxRL21+332π
​Go Average Diode Current of Three Phase Uncontrolled Rectifier
Id(avg)=3nVmax2πRL

How to Evaluate Power Delivered to Load in Three Phase Uncontrolled Rectifier?

Power Delivered to Load in Three Phase Uncontrolled Rectifier evaluator uses Delivery Power = AC Voltage*Average Output Voltage to evaluate the Delivery Power, Power Delivered to Load in Three Phase Uncontrolled Rectifier depends on the configuration of the rectifier, the input voltage, and the load. The power can be calculated based on the rectifier type and load. formula assumes ideal conditions with a purely resistive load and no voltage drops or losses in the rectifier. In practice, there will be some losses in the diodes, and the actual power delivered to the load may be slightly lower. Delivery Power is denoted by Pout symbol.

How to evaluate Power Delivered to Load in Three Phase Uncontrolled Rectifier using this online evaluator? To use this online evaluator for Power Delivered to Load in Three Phase Uncontrolled Rectifier, enter AC Voltage (Vac) & Average Output Voltage (Vdc) and hit the calculate button.

FAQs on Power Delivered to Load in Three Phase Uncontrolled Rectifier

What is the formula to find Power Delivered to Load in Three Phase Uncontrolled Rectifier?
The formula of Power Delivered to Load in Three Phase Uncontrolled Rectifier is expressed as Delivery Power = AC Voltage*Average Output Voltage. Here is an example- 230882.9 = 2100.845*109.9.
How to calculate Power Delivered to Load in Three Phase Uncontrolled Rectifier?
With AC Voltage (Vac) & Average Output Voltage (Vdc) we can find Power Delivered to Load in Three Phase Uncontrolled Rectifier using the formula - Delivery Power = AC Voltage*Average Output Voltage.
Can the Power Delivered to Load in Three Phase Uncontrolled Rectifier be negative?
No, the Power Delivered to Load in Three Phase Uncontrolled Rectifier, measured in Power cannot be negative.
Which unit is used to measure Power Delivered to Load in Three Phase Uncontrolled Rectifier?
Power Delivered to Load in Three Phase Uncontrolled Rectifier is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Power Delivered to Load in Three Phase Uncontrolled Rectifier can be measured.
Copied!