Fx Copy
LaTeX Copy
Power Absorbed refers to the amount of power or energy consumed or taken in by a device, system, or component. Check FAQs
P=2μπ3N2(Ds2)4t
P - Power Absorbed?μ - Viscosity of Fluid?N - Mean Speed in RPM?Ds - Shaft Diameter?t - Thickness of Oil Film?π - Archimedes' constant?

Power Absorbed in Foot-Step Bearing Example

With values
With units
Only example

Here is how the Power Absorbed in Foot-Step Bearing equation looks like with Values.

Here is how the Power Absorbed in Foot-Step Bearing equation looks like with Units.

Here is how the Power Absorbed in Foot-Step Bearing equation looks like.

107.9867Edit=28.23Edit3.141631.0691Edit2(14.9008Edit2)44.6232Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Fluid Mechanics » fx Power Absorbed in Foot-Step Bearing

Power Absorbed in Foot-Step Bearing Solution

Follow our step by step solution on how to calculate Power Absorbed in Foot-Step Bearing?

FIRST Step Consider the formula
P=2μπ3N2(Ds2)4t
Next Step Substitute values of Variables
P=28.23N*s/m²π31.0691rev/min2(14.9008m2)44.6232m
Next Step Substitute values of Constants
P=28.23N*s/m²3.141631.0691rev/min2(14.9008m2)44.6232m
Next Step Convert Units
P=28.23Pa*s3.141630.0178Hz2(14.9008m2)44.6232m
Next Step Prepare to Evaluate
P=28.233.141630.01782(14.90082)44.6232
Next Step Evaluate
P=107.98667750871W
LAST Step Rounding Answer
P=107.9867W

Power Absorbed in Foot-Step Bearing Formula Elements

Variables
Constants
Power Absorbed
Power Absorbed refers to the amount of power or energy consumed or taken in by a device, system, or component.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Viscosity of Fluid
The Viscosity of fluid is a measure of its resistance to deformation at a given rate.
Symbol: μ
Measurement: Dynamic ViscosityUnit: N*s/m²
Note: Value can be positive or negative.
Mean Speed in RPM
Mean Speed in RPM is an average of individual vehicle speeds.
Symbol: N
Measurement: FrequencyUnit: rev/min
Note: Value should be greater than 0.
Shaft Diameter
Shaft Diameter is the diameter of the shaft of the pile.
Symbol: Ds
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Thickness of Oil Film
Thickness of Oil Film refers to the distance or dimension between the surfaces that are separated by a layer of oil.
Symbol: t
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other Formulas to find Power Absorbed

​Go Power Absorbed in Overcoming Viscous Resistance in Journal Bearing
P=μπ3Ds3N2Lt

Other formulas in Flow Analysis category

​Go Difference of Pressure for Viscous or Laminar Flow
Δp=32μvaLdo2
​Go Difference of Pressure for Viscous Flow between Two Parallel Plates
Δp=12μVLt2
​Go Loss of Pressure Head for Viscous Flow through Circular Pipe
hf=32μVLρ[g]Dp2
​Go Loss of Pressure Head for Viscous Flow between Two Parallel Plates
hf=12μVLρ[g]t2

How to Evaluate Power Absorbed in Foot-Step Bearing?

Power Absorbed in Foot-Step Bearing evaluator uses Power Absorbed = (2*Viscosity of Fluid*pi^3*Mean Speed in RPM^2*(Shaft Diameter/2)^4)/(Thickness of Oil Film) to evaluate the Power Absorbed, Power Absorbed in Foot-Step Bearing depends on the frictional force, the angular velocity of the shaft, and the radius of the bearing. It is directly proportional to the frictional force (which is a product of the axial load and the coefficient of friction) and the angular velocity of the shaft. The radius of the bearing also plays a role, with power absorption increasing with larger radii. Power Absorbed is denoted by P symbol.

How to evaluate Power Absorbed in Foot-Step Bearing using this online evaluator? To use this online evaluator for Power Absorbed in Foot-Step Bearing, enter Viscosity of Fluid (μ), Mean Speed in RPM (N), Shaft Diameter (Ds) & Thickness of Oil Film (t) and hit the calculate button.

FAQs on Power Absorbed in Foot-Step Bearing

What is the formula to find Power Absorbed in Foot-Step Bearing?
The formula of Power Absorbed in Foot-Step Bearing is expressed as Power Absorbed = (2*Viscosity of Fluid*pi^3*Mean Speed in RPM^2*(Shaft Diameter/2)^4)/(Thickness of Oil Film). Here is an example- 107.9867 = (2*8.23*pi^3*0.0178179333333333^2*(14.90078/2)^4)/(4.623171).
How to calculate Power Absorbed in Foot-Step Bearing?
With Viscosity of Fluid (μ), Mean Speed in RPM (N), Shaft Diameter (Ds) & Thickness of Oil Film (t) we can find Power Absorbed in Foot-Step Bearing using the formula - Power Absorbed = (2*Viscosity of Fluid*pi^3*Mean Speed in RPM^2*(Shaft Diameter/2)^4)/(Thickness of Oil Film). This formula also uses Archimedes' constant .
What are the other ways to Calculate Power Absorbed?
Here are the different ways to Calculate Power Absorbed-
  • Power Absorbed=(Viscosity of Fluid*pi^3*Shaft Diameter^3*Mean Speed in RPM^2*Length of Pipe)/Thickness of Oil FilmOpenImg
Can the Power Absorbed in Foot-Step Bearing be negative?
No, the Power Absorbed in Foot-Step Bearing, measured in Power cannot be negative.
Which unit is used to measure Power Absorbed in Foot-Step Bearing?
Power Absorbed in Foot-Step Bearing is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Power Absorbed in Foot-Step Bearing can be measured.