The Possible Recharge refers to the gross recharge minus the natural recharge of the area. Check FAQs
R=Rrf+Rgw+Rwt+Rt
R - Possible Recharge?Rrf - Recharge from Rainfall?Rgw - Recharge from Irrigation?Rwt - Recharge from Conservation Structures?Rt - Recharge from Tanks and Ponds?

Possible Recharge given other Recharge Factors Example

With values
With units
Only example

Here is how the Possible Recharge given other Recharge Factors equation looks like with Values.

Here is how the Possible Recharge given other Recharge Factors equation looks like with Units.

Here is how the Possible Recharge given other Recharge Factors equation looks like.

70Edit=16Edit+19Edit+21Edit+14Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Possible Recharge given other Recharge Factors

Possible Recharge given other Recharge Factors Solution

Follow our step by step solution on how to calculate Possible Recharge given other Recharge Factors?

FIRST Step Consider the formula
R=Rrf+Rgw+Rwt+Rt
Next Step Substitute values of Variables
R=16m³/s+19m³/s+21m³/s+14m³/s
Next Step Prepare to Evaluate
R=16+19+21+14
LAST Step Evaluate
R=70m³/s

Possible Recharge given other Recharge Factors Formula Elements

Variables
Possible Recharge
The Possible Recharge refers to the gross recharge minus the natural recharge of the area.
Symbol: R
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Recharge from Rainfall
The Recharge from Rainfall refers to the process by which precipitation replenishes the groundwater supply.
Symbol: Rrf
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Recharge from Irrigation
The Recharge from Irrigation refers to the process of replenishing groundwater through deliberate human actions related to irrigation practices.
Symbol: Rgw
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Recharge from Conservation Structures
The Recharge from Conservation Structures refers to the practice of intentionally increasing the amount of water that enters an aquifer through human-controlled means.
Symbol: Rwt
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Recharge from Tanks and Ponds
The Recharge from Tanks and Ponds refers to a method of replenishing groundwater by directing water into the ground from surface storage structures.
Symbol: Rt
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other Formulas to find Possible Recharge

​Go Possible Recharge given Gross Recharge due to Rainfall
R=RG-B+I+Is
​Go Equation for Recharge when Gross Water Draft is Considered
R=(hSYA)-DG

Other formulas in Groundwater Level Fluctuation category

​Go Equation for Specific Yield
SY=RG-DG-B+Is+IAh
​Go Equation for Gross Recharge due to Rainfall and other Sources
RG=(hSYA)+DG+B-Is-I
​Go Equation for Gross Water Draft
DG=RG-B+Is+I-(hSYA)
​Go Equation for Base Flow into Stream from Area
B=RG-DG+Is+I-(hSYA)

How to Evaluate Possible Recharge given other Recharge Factors?

Possible Recharge given other Recharge Factors evaluator uses Possible Recharge = Recharge from Rainfall+Recharge from Irrigation+Recharge from Conservation Structures+Recharge from Tanks and Ponds to evaluate the Possible Recharge, The Possible Recharge given other Recharge Factors formula is defined as the hydrologic process, where water moves downward from every possible source like rainfall, irrigation, ponds, lakes, uncultivated strips, shelterbelts, terraces to groundwater. Possible Recharge is denoted by R symbol.

How to evaluate Possible Recharge given other Recharge Factors using this online evaluator? To use this online evaluator for Possible Recharge given other Recharge Factors, enter Recharge from Rainfall (Rrf), Recharge from Irrigation (Rgw), Recharge from Conservation Structures (Rwt) & Recharge from Tanks and Ponds (Rt) and hit the calculate button.

FAQs on Possible Recharge given other Recharge Factors

What is the formula to find Possible Recharge given other Recharge Factors?
The formula of Possible Recharge given other Recharge Factors is expressed as Possible Recharge = Recharge from Rainfall+Recharge from Irrigation+Recharge from Conservation Structures+Recharge from Tanks and Ponds. Here is an example- 70 = 16+19+21+14.
How to calculate Possible Recharge given other Recharge Factors?
With Recharge from Rainfall (Rrf), Recharge from Irrigation (Rgw), Recharge from Conservation Structures (Rwt) & Recharge from Tanks and Ponds (Rt) we can find Possible Recharge given other Recharge Factors using the formula - Possible Recharge = Recharge from Rainfall+Recharge from Irrigation+Recharge from Conservation Structures+Recharge from Tanks and Ponds.
What are the other ways to Calculate Possible Recharge?
Here are the different ways to Calculate Possible Recharge-
  • Possible Recharge=Gross Recharge due to Rainfall-Base Flow into the Stream from the Area+Net Ground Water Flowing Outside Catchment+Recharge of Ground Water BodyOpenImg
  • Possible Recharge=(Water Level Fluctuation*Specific Yield*Watershed Area)-Gross Water DraftOpenImg
Can the Possible Recharge given other Recharge Factors be negative?
No, the Possible Recharge given other Recharge Factors, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Possible Recharge given other Recharge Factors?
Possible Recharge given other Recharge Factors is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Possible Recharge given other Recharge Factors can be measured.
Copied!