Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) Formula

Fx Copy
LaTeX Copy
Positive Sequence Voltage in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Check FAQs
V1(tco)=Ea(tco)-I1(tco)Z1(tco)
V1(tco) - Positive Sequence Voltage in TCO?Ea(tco) - A Phase EMF in TCO?I1(tco) - Positive Sequence Current in TCO?Z1(tco) - Positive Sequence Impedance in TCO?

Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) Example

With values
With units
Only example

Here is how the Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) equation looks like with Values.

Here is how the Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) equation looks like with Units.

Here is how the Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) equation looks like.

105.4005Edit=121.38Edit-2.01Edit7.95Edit
You are here -

Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) Solution

Follow our step by step solution on how to calculate Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open)?

FIRST Step Consider the formula
V1(tco)=Ea(tco)-I1(tco)Z1(tco)
Next Step Substitute values of Variables
V1(tco)=121.38V-2.01A7.95Ω
Next Step Prepare to Evaluate
V1(tco)=121.38-2.017.95
LAST Step Evaluate
V1(tco)=105.4005V

Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) Formula Elements

Variables
Positive Sequence Voltage in TCO
Positive Sequence Voltage in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: V1(tco)
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
A Phase EMF in TCO
A Phase EMF in TCO is defined as the electromagnetic force of the a-phase in open conductor fault.
Symbol: Ea(tco)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Positive Sequence Current in TCO
Positive Sequence Current in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: I1(tco)
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.
Positive Sequence Impedance in TCO
Positive Sequence Impedance in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: Z1(tco)
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other formulas in Positive Sequence category

​Go Positive Sequence Current (Two Conductor Open)
I1(tco)=Ia(tco)3
​Go Positive Sequence Potential Difference (Two Conductor Open)
Vaa'1(tco)=((-1)Vaa'2(tco))-Vaa'0(tco)
​Go Positive Sequence Impedance using A-Phase EMF (Two Conductor Open)
Z1(tco)=(Ea(tco)I1(tco))-Z0(tco)-Z2(tco)
​Go Positive Sequence Current using A-Phase EMF (Two Conductor Open)
I1(tco)=Ea(tco)Z0(tco)+Z1(tco)+Z2(tco)

How to Evaluate Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open)?

Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) evaluator uses Positive Sequence Voltage in TCO = A Phase EMF in TCO-Positive Sequence Current in TCO*Positive Sequence Impedance in TCO to evaluate the Positive Sequence Voltage in TCO, The Positive Sequence Voltage using Positive Sequence Current (Two conductor open) formula is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Positive Sequence Voltage in TCO is denoted by V1(tco) symbol.

How to evaluate Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) using this online evaluator? To use this online evaluator for Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open), enter A Phase EMF in TCO (Ea(tco)), Positive Sequence Current in TCO (I1(tco)) & Positive Sequence Impedance in TCO (Z1(tco)) and hit the calculate button.

FAQs on Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open)

What is the formula to find Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open)?
The formula of Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) is expressed as Positive Sequence Voltage in TCO = A Phase EMF in TCO-Positive Sequence Current in TCO*Positive Sequence Impedance in TCO. Here is an example- 105.4005 = 121.38-2.01*7.95.
How to calculate Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open)?
With A Phase EMF in TCO (Ea(tco)), Positive Sequence Current in TCO (I1(tco)) & Positive Sequence Impedance in TCO (Z1(tco)) we can find Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) using the formula - Positive Sequence Voltage in TCO = A Phase EMF in TCO-Positive Sequence Current in TCO*Positive Sequence Impedance in TCO.
Can the Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) be negative?
No, the Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open), measured in Electric Potential cannot be negative.
Which unit is used to measure Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open)?
Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open) can be measured.
Copied!