Fx Copy
LaTeX Copy
Positive Sequence Voltage consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Check FAQs
V1=Ea-Z1I1
V1 - Positive Sequence Voltage?Ea - A Phase EMF?Z1 - Positive Sequence Impedance?I1 - Positive Sequence Current?

Positive Sequence Voltage using A-Phase EMF(LLGF) Example

With values
With units
Only example

Here is how the Positive Sequence Voltage using A-Phase EMF(LLGF) equation looks like with Values.

Here is how the Positive Sequence Voltage using A-Phase EMF(LLGF) equation looks like with Units.

Here is how the Positive Sequence Voltage using A-Phase EMF(LLGF) equation looks like.

13.4921Edit=29.38Edit-7.94Edit2.001Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Positive Sequence Voltage using A-Phase EMF(LLGF)

Positive Sequence Voltage using A-Phase EMF(LLGF) Solution

Follow our step by step solution on how to calculate Positive Sequence Voltage using A-Phase EMF(LLGF)?

FIRST Step Consider the formula
V1=Ea-Z1I1
Next Step Substitute values of Variables
V1=29.38V-7.94Ω2.001A
Next Step Prepare to Evaluate
V1=29.38-7.942.001
Next Step Evaluate
V1=13.49206V
LAST Step Rounding Answer
V1=13.4921V

Positive Sequence Voltage using A-Phase EMF(LLGF) Formula Elements

Variables
Positive Sequence Voltage
Positive Sequence Voltage consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: V1
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
A Phase EMF
A phase EMF is defined as the electromagnetic force of the a-phase in open conductor fault.
Symbol: Ea
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Positive Sequence Impedance
Positive Sequence Impedance consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: Z1
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Positive Sequence Current
Positive Sequence Current consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: I1
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other Formulas to find Positive Sequence Voltage

​Go Positive Sequence Voltage using Fault Impedance (LLGF)
V1=V0-(3ZfI0)

Other formulas in Voltage and EMF category

​Go B-Phase Voltage using Fault Current (LLGF)
Vb=ZfIf
​Go C-Phase Voltage using Fault Current (LLGF)
Vc=IfZf
​Go B-Phase Voltage using Zero Sequence Current (LLGF)
Vb=3I0Zf
​Go C-Phase Voltage using Zero Sequence Current (LLGF)
Vc=3I0Zf

How to Evaluate Positive Sequence Voltage using A-Phase EMF(LLGF)?

Positive Sequence Voltage using A-Phase EMF(LLGF) evaluator uses Positive Sequence Voltage = A Phase EMF-Positive Sequence Impedance*Positive Sequence Current to evaluate the Positive Sequence Voltage, The Positive Sequence Voltage using A-phase EMF(LLGF) formula consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Positive Sequence Voltage is denoted by V1 symbol.

How to evaluate Positive Sequence Voltage using A-Phase EMF(LLGF) using this online evaluator? To use this online evaluator for Positive Sequence Voltage using A-Phase EMF(LLGF), enter A Phase EMF (Ea), Positive Sequence Impedance (Z1) & Positive Sequence Current (I1) and hit the calculate button.

FAQs on Positive Sequence Voltage using A-Phase EMF(LLGF)

What is the formula to find Positive Sequence Voltage using A-Phase EMF(LLGF)?
The formula of Positive Sequence Voltage using A-Phase EMF(LLGF) is expressed as Positive Sequence Voltage = A Phase EMF-Positive Sequence Impedance*Positive Sequence Current. Here is an example- 13.49206 = 29.38-7.94*2.001.
How to calculate Positive Sequence Voltage using A-Phase EMF(LLGF)?
With A Phase EMF (Ea), Positive Sequence Impedance (Z1) & Positive Sequence Current (I1) we can find Positive Sequence Voltage using A-Phase EMF(LLGF) using the formula - Positive Sequence Voltage = A Phase EMF-Positive Sequence Impedance*Positive Sequence Current.
What are the other ways to Calculate Positive Sequence Voltage?
Here are the different ways to Calculate Positive Sequence Voltage-
  • Positive Sequence Voltage=Zero Sequence Voltage-(3*Fault Impedance*Zero Sequence Current)OpenImg
Can the Positive Sequence Voltage using A-Phase EMF(LLGF) be negative?
No, the Positive Sequence Voltage using A-Phase EMF(LLGF), measured in Electric Potential cannot be negative.
Which unit is used to measure Positive Sequence Voltage using A-Phase EMF(LLGF)?
Positive Sequence Voltage using A-Phase EMF(LLGF) is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Positive Sequence Voltage using A-Phase EMF(LLGF) can be measured.
Copied!