Fx Copy
LaTeX Copy
Positive Sequence Voltage LG consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Check FAQs
V1(lg)=E1(lg)-(Z1(lg)I1(lg))
V1(lg) - Positive Sequence Voltage LG?E1(lg) - EMF Induced in Primary Winding LG?Z1(lg) - Positive Sequence Impedance LG?I1(lg) - Positive Sequence Current LG?

Positive Sequence Voltage for L-G-F Example

With values
With units
Only example

Here is how the Positive Sequence Voltage for L-G-F equation looks like with Values.

Here is how the Positive Sequence Voltage for L-G-F equation looks like with Units.

Here is how the Positive Sequence Voltage for L-G-F equation looks like.

4.6121Edit=20.5Edit-(7.94Edit2.001Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Positive Sequence Voltage for L-G-F

Positive Sequence Voltage for L-G-F Solution

Follow our step by step solution on how to calculate Positive Sequence Voltage for L-G-F?

FIRST Step Consider the formula
V1(lg)=E1(lg)-(Z1(lg)I1(lg))
Next Step Substitute values of Variables
V1(lg)=20.5V-(7.94Ω2.001A)
Next Step Prepare to Evaluate
V1(lg)=20.5-(7.942.001)
Next Step Evaluate
V1(lg)=4.61206V
LAST Step Rounding Answer
V1(lg)=4.6121V

Positive Sequence Voltage for L-G-F Formula Elements

Variables
Positive Sequence Voltage LG
Positive Sequence Voltage LG consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: V1(lg)
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
EMF Induced in Primary Winding LG
EMF Induced in Primary Winding LG is the production of voltage in a coil because of the change in magnetic flux through a coil.
Symbol: E1(lg)
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Positive Sequence Impedance LG
Positive Sequence Impedance LG consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: Z1(lg)
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Positive Sequence Current LG
Positive Sequence Current LG consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: I1(lg)
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other Formulas to find Positive Sequence Voltage LG

​Go Positive Sequence Voltage using A-Phase EMF and Sequence Impedances(LGF)
V1(lg)=Ea(lg)(Z0(lg)+Z2(lg))Z0(lg)+Z1(lg)+Z2(lg)
​Go Positive Sequence Voltage using Positive Sequence Current
V1(lg)=3Zf(lg)I1(lg)

Other formulas in Voltage and EMF category

​Go Zero Sequence Voltage using A-Phase Current (LGF)
V0(lg)=(Zf(lg)Ia(lg))-(V2(lg))-(V1(lg))
​Go A-Phase Voltage(LGF)
Va(lg)=Zf(lg)Ia(lg)
​Go Zero Sequence Voltage for LGF
V0(lg)=-Z0(lg)I0(lg)
​Go A-Phase EMF using Positive Sequence Voltage (LGF)
Ea(lg)=V1(lg)+(Z1(lg)I1(lg))

How to Evaluate Positive Sequence Voltage for L-G-F?

Positive Sequence Voltage for L-G-F evaluator uses Positive Sequence Voltage LG = EMF Induced in Primary Winding LG-(Positive Sequence Impedance LG*Positive Sequence Current LG) to evaluate the Positive Sequence Voltage LG, The Positive Sequence Voltage for L-G-F formula consists of balanced three-phase voltage phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Positive Sequence Voltage LG is denoted by V1(lg) symbol.

How to evaluate Positive Sequence Voltage for L-G-F using this online evaluator? To use this online evaluator for Positive Sequence Voltage for L-G-F, enter EMF Induced in Primary Winding LG (E1(lg)), Positive Sequence Impedance LG (Z1(lg)) & Positive Sequence Current LG (I1(lg)) and hit the calculate button.

FAQs on Positive Sequence Voltage for L-G-F

What is the formula to find Positive Sequence Voltage for L-G-F?
The formula of Positive Sequence Voltage for L-G-F is expressed as Positive Sequence Voltage LG = EMF Induced in Primary Winding LG-(Positive Sequence Impedance LG*Positive Sequence Current LG). Here is an example- 4.61206 = 20.5-(7.94*2.001).
How to calculate Positive Sequence Voltage for L-G-F?
With EMF Induced in Primary Winding LG (E1(lg)), Positive Sequence Impedance LG (Z1(lg)) & Positive Sequence Current LG (I1(lg)) we can find Positive Sequence Voltage for L-G-F using the formula - Positive Sequence Voltage LG = EMF Induced in Primary Winding LG-(Positive Sequence Impedance LG*Positive Sequence Current LG).
What are the other ways to Calculate Positive Sequence Voltage LG?
Here are the different ways to Calculate Positive Sequence Voltage LG-
  • Positive Sequence Voltage LG=(A Phase EMF LG*(Zero Sequence Impedance LG+Negative Sequence Impedance LG))/(Zero Sequence Impedance LG+Positive Sequence Impedance LG+Negative Sequence Impedance LG)OpenImg
  • Positive Sequence Voltage LG=3*Fault Impedance LG*Positive Sequence Current LGOpenImg
Can the Positive Sequence Voltage for L-G-F be negative?
No, the Positive Sequence Voltage for L-G-F, measured in Electric Potential cannot be negative.
Which unit is used to measure Positive Sequence Voltage for L-G-F?
Positive Sequence Voltage for L-G-F is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Positive Sequence Voltage for L-G-F can be measured.
Copied!