Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) Formula

Fx Copy
LaTeX Copy
Positive Sequence Impedance in OCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Check FAQs
Z1(oco)=Ea(oco)-V1(oco)I1(oco)
Z1(oco) - Positive Sequence Impedance in OCO?Ea(oco) - A Phase EMF in OCO?V1(oco) - Positive Sequence Voltage in OCO?I1(oco) - Positive Sequence Current in OCO?

Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) Example

With values
With units
Only example

Here is how the Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) equation looks like with Values.

Here is how the Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) equation looks like with Units.

Here is how the Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) equation looks like.

7.936Edit=29.38Edit-13.5Edit2.001Edit
You are here -

Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) Solution

Follow our step by step solution on how to calculate Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open)?

FIRST Step Consider the formula
Z1(oco)=Ea(oco)-V1(oco)I1(oco)
Next Step Substitute values of Variables
Z1(oco)=29.38V-13.5V2.001A
Next Step Prepare to Evaluate
Z1(oco)=29.38-13.52.001
Next Step Evaluate
Z1(oco)=7.936031984008Ω
LAST Step Rounding Answer
Z1(oco)=7.936Ω

Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) Formula Elements

Variables
Positive Sequence Impedance in OCO
Positive Sequence Impedance in OCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: Z1(oco)
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
A Phase EMF in OCO
A phase EMF in OCO is defined as the electromagnetic force of the a-phase in open conductor fault.
Symbol: Ea(oco)
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Positive Sequence Voltage in OCO
Positive Sequence Voltage in OCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: V1(oco)
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Positive Sequence Current in OCO
Positive Sequence Current in OCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: I1(oco)
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other formulas in Positive Sequence category

​Go Positive Sequence Potential Difference using A-Phase Potential Difference (One Conductor Open)
Vaa'1(oco)=Vaa'(oco)3
​Go Positive Sequence Current using Zero Sequence Impedance (One Conductor Open)
I1(oco)=Ea(oco)Z1(oco)+(Z0(oco)Z2(oco)Z0(oco)+Z2(oco))
​Go Positive Sequence Current using Positive Sequence Voltage (One Conductor Open)
I1(oco)=Ea(oco)-V1(oco)Z1(oco)
​Go Positive Sequence Voltage using Positive Sequence Impedance (One Conductor Open)
V1(oco)=Ea(oco)-I1(oco)Z1(oco)

How to Evaluate Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open)?

Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) evaluator uses Positive Sequence Impedance in OCO = (A Phase EMF in OCO-Positive Sequence Voltage in OCO)/Positive Sequence Current in OCO to evaluate the Positive Sequence Impedance in OCO, The Positive Sequence Impedance using Positive Sequence Voltage (One conductor open) formula is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Positive Sequence Impedance in OCO is denoted by Z1(oco) symbol.

How to evaluate Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) using this online evaluator? To use this online evaluator for Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open), enter A Phase EMF in OCO (Ea(oco)), Positive Sequence Voltage in OCO (V1(oco)) & Positive Sequence Current in OCO (I1(oco)) and hit the calculate button.

FAQs on Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open)

What is the formula to find Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open)?
The formula of Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) is expressed as Positive Sequence Impedance in OCO = (A Phase EMF in OCO-Positive Sequence Voltage in OCO)/Positive Sequence Current in OCO. Here is an example- 7.971014 = (29.38-13.5)/2.001.
How to calculate Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open)?
With A Phase EMF in OCO (Ea(oco)), Positive Sequence Voltage in OCO (V1(oco)) & Positive Sequence Current in OCO (I1(oco)) we can find Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) using the formula - Positive Sequence Impedance in OCO = (A Phase EMF in OCO-Positive Sequence Voltage in OCO)/Positive Sequence Current in OCO.
Can the Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) be negative?
No, the Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open), measured in Electric Resistance cannot be negative.
Which unit is used to measure Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open)?
Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Positive Sequence Impedance using Positive Sequence Voltage (One Conductor Open) can be measured.
Copied!