Positive Sequence Current is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Check FAQs
I1=3V1Zd
I1 - Positive Sequence Current?V1 - Positive Sequence Voltage?Zd - Delta Impedance?

Positive Sequence Current for Delta Connected Load Example

With values
With units
Only example

Here is how the Positive Sequence Current for Delta Connected Load equation looks like with Values.

Here is how the Positive Sequence Current for Delta Connected Load equation looks like with Units.

Here is how the Positive Sequence Current for Delta Connected Load equation looks like.

2Edit=36Edit9Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Positive Sequence Current for Delta Connected Load

Positive Sequence Current for Delta Connected Load Solution

Follow our step by step solution on how to calculate Positive Sequence Current for Delta Connected Load?

FIRST Step Consider the formula
I1=3V1Zd
Next Step Substitute values of Variables
I1=36V9Ω
Next Step Prepare to Evaluate
I1=369
LAST Step Evaluate
I1=2A

Positive Sequence Current for Delta Connected Load Formula Elements

Variables
Positive Sequence Current
Positive Sequence Current is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: I1
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Positive Sequence Voltage
Positive Sequence Voltage is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: V1
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Delta Impedance
Delta Impedance is defined as the impedance of delta connected network.
Symbol: Zd
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.

Other Formulas to find Positive Sequence Current

​Go Positive Sequence Current for Star Connected Load
I1=V1Zy

Other formulas in Sequence Current and Voltage category

​Go Negative Sequence Voltage for Star Connected Load
V2=I2Zy
​Go Zero Sequence Voltage for Star Connected Load
V0=(Zy+3Zf)I0
​Go Positive Sequence Voltage for Delta Connected Load
V1=ZdI13
​Go Positive Sequence Voltage for Star Connected Load
V1=ZyI1

How to Evaluate Positive Sequence Current for Delta Connected Load?

Positive Sequence Current for Delta Connected Load evaluator uses Positive Sequence Current = (3*Positive Sequence Voltage)/Delta Impedance to evaluate the Positive Sequence Current, The Positive Sequence Current for Delta Connected Load formula consists of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Positive Sequence Current is denoted by I1 symbol.

How to evaluate Positive Sequence Current for Delta Connected Load using this online evaluator? To use this online evaluator for Positive Sequence Current for Delta Connected Load, enter Positive Sequence Voltage (V1) & Delta Impedance (Zd) and hit the calculate button.

FAQs on Positive Sequence Current for Delta Connected Load

What is the formula to find Positive Sequence Current for Delta Connected Load?
The formula of Positive Sequence Current for Delta Connected Load is expressed as Positive Sequence Current = (3*Positive Sequence Voltage)/Delta Impedance. Here is an example- 2 = (3*6)/9.
How to calculate Positive Sequence Current for Delta Connected Load?
With Positive Sequence Voltage (V1) & Delta Impedance (Zd) we can find Positive Sequence Current for Delta Connected Load using the formula - Positive Sequence Current = (3*Positive Sequence Voltage)/Delta Impedance.
What are the other ways to Calculate Positive Sequence Current?
Here are the different ways to Calculate Positive Sequence Current-
  • Positive Sequence Current=Positive Sequence Voltage/Star ImpedanceOpenImg
Can the Positive Sequence Current for Delta Connected Load be negative?
Yes, the Positive Sequence Current for Delta Connected Load, measured in Electric Current can be negative.
Which unit is used to measure Positive Sequence Current for Delta Connected Load?
Positive Sequence Current for Delta Connected Load is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Positive Sequence Current for Delta Connected Load can be measured.