Fx Copy
LaTeX Copy
Positive Sequence Current consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Check FAQs
I1=(-1)I2
I1 - Positive Sequence Current?I2 - Negative Sequence Current?

Positive Sequence Current (LLF) Example

With values
With units
Only example

Here is how the Positive Sequence Current (LLF) equation looks like with Values.

Here is how the Positive Sequence Current (LLF) equation looks like with Units.

Here is how the Positive Sequence Current (LLF) equation looks like.

0.36Edit=(-1)-0.36Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Positive Sequence Current (LLF)

Positive Sequence Current (LLF) Solution

Follow our step by step solution on how to calculate Positive Sequence Current (LLF)?

FIRST Step Consider the formula
I1=(-1)I2
Next Step Substitute values of Variables
I1=(-1)-0.36A
Next Step Prepare to Evaluate
I1=(-1)-0.36
LAST Step Evaluate
I1=0.36A

Positive Sequence Current (LLF) Formula Elements

Variables
Positive Sequence Current
Positive Sequence Current consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Symbol: I1
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Negative Sequence Current
Negative Sequence Current consists of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation.
Symbol: I2
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other Formulas to find Positive Sequence Current

​Go Positive Sequence Current using Fault Impedance(LLF)
I1=V1-V2Zf
​Go Positive Sequence Current using A-Phase EMF(LLF)
I1=EaZ1+Z2+Zf

Other formulas in Current category

​Go B-Phase Current (LLF)
Ib=(-1)Ic
​Go C-Phase Current(LLF)
Ic=(-1)Ib
​Go Negative Sequence Current(LLF)
I2=(-1)I1
​Go Fault Current(LLF)
If=3EaZ1+Z2

How to Evaluate Positive Sequence Current (LLF)?

Positive Sequence Current (LLF) evaluator uses Positive Sequence Current = (-1)*Negative Sequence Current to evaluate the Positive Sequence Current, The Positive Sequence Current (LLF) formula is defined as consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Positive Sequence Current is denoted by I1 symbol.

How to evaluate Positive Sequence Current (LLF) using this online evaluator? To use this online evaluator for Positive Sequence Current (LLF), enter Negative Sequence Current (I2) and hit the calculate button.

FAQs on Positive Sequence Current (LLF)

What is the formula to find Positive Sequence Current (LLF)?
The formula of Positive Sequence Current (LLF) is expressed as Positive Sequence Current = (-1)*Negative Sequence Current. Here is an example- 0.36 = (-1)*(-0.36).
How to calculate Positive Sequence Current (LLF)?
With Negative Sequence Current (I2) we can find Positive Sequence Current (LLF) using the formula - Positive Sequence Current = (-1)*Negative Sequence Current.
What are the other ways to Calculate Positive Sequence Current?
Here are the different ways to Calculate Positive Sequence Current-
  • Positive Sequence Current=(Positive Sequence Voltage-Negative Sequence Voltage)/Fault ImpedanceOpenImg
  • Positive Sequence Current=A Phase EMF/(Positive Sequence Impedance+Negative Sequence Impedance+Fault Impedance)OpenImg
Can the Positive Sequence Current (LLF) be negative?
Yes, the Positive Sequence Current (LLF), measured in Electric Current can be negative.
Which unit is used to measure Positive Sequence Current (LLF)?
Positive Sequence Current (LLF) is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Positive Sequence Current (LLF) can be measured.
Copied!