Point Efficiency of Absorption Operation Formula

Fx Copy
LaTeX Copy
The Point Efficiency of Absorption Column in percent based on the vapor phase is the gas liquid separation efficiency on each tray for liquid vertically well mixed and gas in plug flow. Check FAQs
EOG=(yN, Local-yN+1, Localylocal, eqm-yN+1, Local)100
EOG - Point Efficiency of Absorption Column in Percent?yN, Local - Local Mole Fraction of Vapor Leaving Nth Plate?yN+1, Local - Local Mole Fraction of Vapor Entering Nth Plate?ylocal, eqm - Local Eqm Mole Fraction of Vapor on Nth Plate?

Point Efficiency of Absorption Operation Example

With values
With units
Only example

Here is how the Point Efficiency of Absorption Operation equation looks like with Values.

Here is how the Point Efficiency of Absorption Operation equation looks like with Units.

Here is how the Point Efficiency of Absorption Operation equation looks like.

75Edit=(0.35Edit-0.41Edit0.33Edit-0.41Edit)100
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Point Efficiency of Absorption Operation

Point Efficiency of Absorption Operation Solution

Follow our step by step solution on how to calculate Point Efficiency of Absorption Operation?

FIRST Step Consider the formula
EOG=(yN, Local-yN+1, Localylocal, eqm-yN+1, Local)100
Next Step Substitute values of Variables
EOG=(0.35-0.410.33-0.41)100
Next Step Prepare to Evaluate
EOG=(0.35-0.410.33-0.41)100
LAST Step Evaluate
EOG=75

Point Efficiency of Absorption Operation Formula Elements

Variables
Point Efficiency of Absorption Column in Percent
The Point Efficiency of Absorption Column in percent based on the vapor phase is the gas liquid separation efficiency on each tray for liquid vertically well mixed and gas in plug flow.
Symbol: EOG
Measurement: NAUnit: Unitless
Note: Value should be less than 100.
Local Mole Fraction of Vapor Leaving Nth Plate
The Local mole fraction of Vapor Leaving Nth Plate is the mole fraction of the gas at any point or location on the tray leaving from the Nth tray.
Symbol: yN, Local
Measurement: NAUnit: Unitless
Note: Value should be less than 1.
Local Mole Fraction of Vapor Entering Nth Plate
The Local mole fraction of Vapor Entering Nth Plate is the mole fraction of the gas at any point or location on the tray leaving from the (N+1)th tray.
Symbol: yN+1, Local
Measurement: NAUnit: Unitless
Note: Value should be less than 1.
Local Eqm Mole Fraction of Vapor on Nth Plate
The Local Eqm Mole Fraction of Vapor on Nth Plate is the mole fraction of the gas that is in equilibrium with the liquid on the Nth tray.
Symbol: ylocal, eqm
Measurement: NAUnit: Unitless
Note: Value should be less than 1.

Other formulas in Gas Absorption and Stripping category

​Go Number of Stripping Stages by Kremser Equation
N=log10((X0(Stripping)-(YN+1(Stripping)α)XN(Stripping)-(YN+1(Stripping)α))(1-(1S))+(1S))log10(S)
​Go Stripping Factor
S=αGs(Stripping)Ls(Stripping)
​Go Stripping Factor given Absorption Factor
S=1A
​Go Absorption Factor
A=LsαGs

How to Evaluate Point Efficiency of Absorption Operation?

Point Efficiency of Absorption Operation evaluator uses Point Efficiency of Absorption Column in Percent = ((Local Mole Fraction of Vapor Leaving Nth Plate-Local Mole Fraction of Vapor Entering Nth Plate)/(Local Eqm Mole Fraction of Vapor on Nth Plate-Local Mole Fraction of Vapor Entering Nth Plate))*100 to evaluate the Point Efficiency of Absorption Column in Percent, The Point Efficiency of Absorption Operation formula is defined as the ratio of actual enrichment of the gas to the maximum enrichment that could have been achieved if equilibrium is reached. Point Efficiency of Absorption Column in Percent is denoted by EOG symbol.

How to evaluate Point Efficiency of Absorption Operation using this online evaluator? To use this online evaluator for Point Efficiency of Absorption Operation, enter Local Mole Fraction of Vapor Leaving Nth Plate (yN, Local), Local Mole Fraction of Vapor Entering Nth Plate (yN+1, Local) & Local Eqm Mole Fraction of Vapor on Nth Plate (ylocal, eqm) and hit the calculate button.

FAQs on Point Efficiency of Absorption Operation

What is the formula to find Point Efficiency of Absorption Operation?
The formula of Point Efficiency of Absorption Operation is expressed as Point Efficiency of Absorption Column in Percent = ((Local Mole Fraction of Vapor Leaving Nth Plate-Local Mole Fraction of Vapor Entering Nth Plate)/(Local Eqm Mole Fraction of Vapor on Nth Plate-Local Mole Fraction of Vapor Entering Nth Plate))*100. Here is an example- 75 = ((0.35-0.41)/(0.33-0.41))*100.
How to calculate Point Efficiency of Absorption Operation?
With Local Mole Fraction of Vapor Leaving Nth Plate (yN, Local), Local Mole Fraction of Vapor Entering Nth Plate (yN+1, Local) & Local Eqm Mole Fraction of Vapor on Nth Plate (ylocal, eqm) we can find Point Efficiency of Absorption Operation using the formula - Point Efficiency of Absorption Column in Percent = ((Local Mole Fraction of Vapor Leaving Nth Plate-Local Mole Fraction of Vapor Entering Nth Plate)/(Local Eqm Mole Fraction of Vapor on Nth Plate-Local Mole Fraction of Vapor Entering Nth Plate))*100.
Copied!