Peripheral Speed of Armature using Limiting Value of Core Length Formula

Fx Copy
LaTeX Copy
Peripheral speed of armature is the distance travel by the armature per unit time is called as peripheral speed. n = speed in r.p.s. Check FAQs
Va=7.5BavLlimitTcnc
Va - Peripheral Speed of Armature?Bav - Specific Magnetic Loading?Llimit - Limiting Value of Core Length?Tc - Turns per Coil?nc - Number of Coils between Adjacent Segments?

Peripheral Speed of Armature using Limiting Value of Core Length Example

With values
With units
Only example

Here is how the Peripheral Speed of Armature using Limiting Value of Core Length equation looks like with Values.

Here is how the Peripheral Speed of Armature using Limiting Value of Core Length equation looks like with Units.

Here is how the Peripheral Speed of Armature using Limiting Value of Core Length equation looks like.

0.0445Edit=7.50.458Edit0.3008Edit204Edit6Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Electrical Machine Design » fx Peripheral Speed of Armature using Limiting Value of Core Length

Peripheral Speed of Armature using Limiting Value of Core Length Solution

Follow our step by step solution on how to calculate Peripheral Speed of Armature using Limiting Value of Core Length?

FIRST Step Consider the formula
Va=7.5BavLlimitTcnc
Next Step Substitute values of Variables
Va=7.50.458Wb/m²0.3008m2046
Next Step Convert Units
Va=7.50.458T0.3008m2046
Next Step Prepare to Evaluate
Va=7.50.4580.30082046
Next Step Evaluate
Va=0.0444771074833352m/s
LAST Step Rounding Answer
Va=0.0445m/s

Peripheral Speed of Armature using Limiting Value of Core Length Formula Elements

Variables
Peripheral Speed of Armature
Peripheral speed of armature is the distance travel by the armature per unit time is called as peripheral speed. n = speed in r.p.s.
Symbol: Va
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Specific Magnetic Loading
Specific Magnetic loading is defined as the total flux per unit area over the surface of the armature periphery and is denoted by Bav for any electrical machine.
Symbol: Bav
Measurement: Magnetic Flux DensityUnit: Wb/m²
Note: Value can be positive or negative.
Limiting Value of Core Length
Limiting value of Core length is the emf induced in a conductor should exceed 7.5/TcNc in order that the maximum value at load between adjacent segments limited to 30 V.
Symbol: Llimit
Measurement: LengthUnit: m
Note: Value should be less than 0.37.
Turns per Coil
Turns per coil refers to the number of turns or windings of wire in each coil of the machine's winding system.
Symbol: Tc
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Number of Coils between Adjacent Segments
Number of coils between adjacent segments ,1 for simplex lap winding and P/2 for a simplex wave winding.
Symbol: nc
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in DC Machines category

​Go Limiting Value of Core Length
Llimit=7.5BavVaTcnc
​Go Average Gap Density using Limiting Value of Core Length
Bav=7.5LlimitVaTcnc
​Go Number of Poles using Magnetic Loading
n=BΦ
​Go Flux per Pole using Magnetic Loading
Φ=Bn

How to Evaluate Peripheral Speed of Armature using Limiting Value of Core Length?

Peripheral Speed of Armature using Limiting Value of Core Length evaluator uses Peripheral Speed of Armature = (7.5)/(Specific Magnetic Loading*Limiting Value of Core Length*Turns per Coil*Number of Coils between Adjacent Segments) to evaluate the Peripheral Speed of Armature, The Peripheral speed of armature using limiting value of core length refers to the speed on the periphery or the circumference of the rotor. The peripheral speed is given by the product of the circumference (2πR) and the speed (RPM). The peripheral speed is dependent on the speed as well as the diameter of the rotor. Peripheral Speed of Armature is denoted by Va symbol.

How to evaluate Peripheral Speed of Armature using Limiting Value of Core Length using this online evaluator? To use this online evaluator for Peripheral Speed of Armature using Limiting Value of Core Length, enter Specific Magnetic Loading (Bav), Limiting Value of Core Length (Llimit), Turns per Coil (Tc) & Number of Coils between Adjacent Segments (nc) and hit the calculate button.

FAQs on Peripheral Speed of Armature using Limiting Value of Core Length

What is the formula to find Peripheral Speed of Armature using Limiting Value of Core Length?
The formula of Peripheral Speed of Armature using Limiting Value of Core Length is expressed as Peripheral Speed of Armature = (7.5)/(Specific Magnetic Loading*Limiting Value of Core Length*Turns per Coil*Number of Coils between Adjacent Segments). Here is an example- 0.044477 = (7.5)/(0.458*0.3008*204*6).
How to calculate Peripheral Speed of Armature using Limiting Value of Core Length?
With Specific Magnetic Loading (Bav), Limiting Value of Core Length (Llimit), Turns per Coil (Tc) & Number of Coils between Adjacent Segments (nc) we can find Peripheral Speed of Armature using Limiting Value of Core Length using the formula - Peripheral Speed of Armature = (7.5)/(Specific Magnetic Loading*Limiting Value of Core Length*Turns per Coil*Number of Coils between Adjacent Segments).
Can the Peripheral Speed of Armature using Limiting Value of Core Length be negative?
No, the Peripheral Speed of Armature using Limiting Value of Core Length, measured in Speed cannot be negative.
Which unit is used to measure Peripheral Speed of Armature using Limiting Value of Core Length?
Peripheral Speed of Armature using Limiting Value of Core Length is usually measured using the Meter per Second[m/s] for Speed. Meter per Minute[m/s], Meter per Hour[m/s], Kilometer per Hour[m/s] are the few other units in which Peripheral Speed of Armature using Limiting Value of Core Length can be measured.
Copied!