Period of Occurrence of Fire given Quantity of Water Formula

Fx Copy
LaTeX Copy
Time Period is the time period of occurrence of fire. Check FAQs
T=((Qw((td60)+12)0.7574360)10.275)31556952
T - Time Period?Qw - Quantity of Water?td - Time Duration?

Period of Occurrence of Fire given Quantity of Water Example

With values
With units
Only example

Here is how the Period of Occurrence of Fire given Quantity of Water equation looks like with Values.

Here is how the Period of Occurrence of Fire given Quantity of Water equation looks like with Units.

Here is how the Period of Occurrence of Fire given Quantity of Water equation looks like.

3Edit=((759.265Edit((3Edit60)+12)0.7574360)10.275)31556952
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Period of Occurrence of Fire given Quantity of Water

Period of Occurrence of Fire given Quantity of Water Solution

Follow our step by step solution on how to calculate Period of Occurrence of Fire given Quantity of Water?

FIRST Step Consider the formula
T=((Qw((td60)+12)0.7574360)10.275)31556952
Next Step Substitute values of Variables
T=((759.265L/min((3min60)+12)0.7574360)10.275)31556952
Next Step Convert Units
T=((759.265L/min((180s60)+12)0.7574360)10.275)31556952
Next Step Prepare to Evaluate
T=((759.265((18060)+12)0.7574360)10.275)31556952
Next Step Evaluate
T=94670562.2029695s
Next Step Convert to Output's Unit
T=2.99999068994273Year
LAST Step Rounding Answer
T=3Year

Period of Occurrence of Fire given Quantity of Water Formula Elements

Variables
Time Period
Time Period is the time period of occurrence of fire.
Symbol: T
Measurement: TimeUnit: Year
Note: Value should be greater than 0.
Quantity of Water
The Quantity of Water is the amount of water required to extinguish a fire. It is the discharge in liters per minute.
Symbol: Qw
Measurement: Volumetric Flow RateUnit: L/min
Note: Value can be positive or negative.
Time Duration
Time Duration is the time duration of fire.
Symbol: td
Measurement: TimeUnit: min
Note: Value should be greater than 0.

Other formulas in Fire Demand category

​Go Quantity of Water by Kuichling's Formula
Q=3182P
​Go Population by Kuichling's Formula given Quantity of Water
P=(Q3182)2
​Go Quantity of Water by Buston's Formula
Q=(5663P)
​Go Population by Buston's Formula given Quantity of Water
P=(Q5663)2

How to Evaluate Period of Occurrence of Fire given Quantity of Water?

Period of Occurrence of Fire given Quantity of Water evaluator uses Time Period = ((Quantity of Water*(((Time Duration/60)+12)^(0.757))/4360)^(1/0.275))*31556952 to evaluate the Time Period, The Period of Occurrence of Fire given Quantity of Water formula is defined as it calculates the period of occurrence of fire when we have prior information of other parameters used. Time Period is denoted by T symbol.

How to evaluate Period of Occurrence of Fire given Quantity of Water using this online evaluator? To use this online evaluator for Period of Occurrence of Fire given Quantity of Water, enter Quantity of Water (Qw) & Time Duration (td) and hit the calculate button.

FAQs on Period of Occurrence of Fire given Quantity of Water

What is the formula to find Period of Occurrence of Fire given Quantity of Water?
The formula of Period of Occurrence of Fire given Quantity of Water is expressed as Time Period = ((Quantity of Water*(((Time Duration/60)+12)^(0.757))/4360)^(1/0.275))*31556952. Here is an example- 9.5E-8 = ((0.0126544166666667*(((180/60)+12)^(0.757))/4360)^(1/0.275))*31556952.
How to calculate Period of Occurrence of Fire given Quantity of Water?
With Quantity of Water (Qw) & Time Duration (td) we can find Period of Occurrence of Fire given Quantity of Water using the formula - Time Period = ((Quantity of Water*(((Time Duration/60)+12)^(0.757))/4360)^(1/0.275))*31556952.
Can the Period of Occurrence of Fire given Quantity of Water be negative?
No, the Period of Occurrence of Fire given Quantity of Water, measured in Time cannot be negative.
Which unit is used to measure Period of Occurrence of Fire given Quantity of Water?
Period of Occurrence of Fire given Quantity of Water is usually measured using the Year[Year] for Time. Second[Year], Millisecond[Year], Microsecond[Year] are the few other units in which Period of Occurrence of Fire given Quantity of Water can be measured.
Copied!