Fx Copy
LaTeX Copy
Column Performance refers to how effectively the column carries out the change in composition with height for a unit driving force available. Check FAQs
J=k'gaGm
J - Column Performance?k'g - Gas Film Transfer Coefficient?a - Interfacial Area per Volume?Gm - Molar Gas Flowrate?

Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate Example

With values
With units
Only example

Here is how the Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate equation looks like with Values.

Here is how the Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate equation looks like with Units.

Here is how the Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate equation looks like.

1.661Edit=18.8741Edit0.1788Edit2.0318Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate

Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate Solution

Follow our step by step solution on how to calculate Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate?

FIRST Step Consider the formula
J=k'gaGm
Next Step Substitute values of Variables
J=18.8741mol/s*m²0.17882.0318mol/s*m²
Next Step Prepare to Evaluate
J=18.87410.17882.0318
Next Step Evaluate
J=1.66101316522434
LAST Step Rounding Answer
J=1.661

Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate Formula Elements

Variables
Column Performance
Column Performance refers to how effectively the column carries out the change in composition with height for a unit driving force available.
Symbol: J
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Gas Film Transfer Coefficient
Gas Film Transfer Coefficient defines the rate at which a component of a gas mixture transfers from the bulk gas phase to the surface of a liquid or solid phase.
Symbol: k'g
Measurement: Molar Flux of Diffusing ComponentUnit: mol/s*m²
Note: Value should be greater than 0.
Interfacial Area per Volume
Interfacial Area per Volume refers to the surface area of the interface between the two phases (usually a liquid and a gas) per unit volume of the packing material.
Symbol: a
Measurement: AreaUnit:
Note: Value should be greater than 0.
Molar Gas Flowrate
Molar Gas Flowrate is defined as the Molar flowrate per unit cross sectional area of the gaseous component.
Symbol: Gm
Measurement: Molar Flux of Diffusing ComponentUnit: mol/s*m²
Note: Value should be greater than 0.

Other Formulas to find Column Performance

​Go Performance of Column for Known Value of Height of Transfer Unit
J=1HOG

Other formulas in Packed Column Designing category

​Go Effective Interfacial Area of Packing using Onda's Method
aW=a(1-exp((-1.45((σcσL)0.75)(LWaμL)0.1)((LW)2a(ρL)2[g])-0.05)(LW2ρLaσL)0.2)
​Go Height of Overall Gas Phase Transfer Unit in Packed Column
HOG=GmKGaP
​Go Liquid Mass Film Coefficient in Packed Columns
KL=0.0051((LWVPaWμL)23)((μLρLDc)-12)((adpVP)0.4)(μL[g]ρL)13
​Go Log Mean Driving Force Based on Mole Fraction
Δylm=y1-y2ln(y1-yey2-ye)

How to Evaluate Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate?

Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate evaluator uses Column Performance = (Gas Film Transfer Coefficient*Interfacial Area per Volume)/Molar Gas Flowrate to evaluate the Column Performance, The Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate formula refers to how effectively the column carries out the separation or absorption of components in a fluid mixture. Column Performance is denoted by J symbol.

How to evaluate Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate using this online evaluator? To use this online evaluator for Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate, enter Gas Film Transfer Coefficient (k'g), Interfacial Area per Volume (a) & Molar Gas Flowrate (Gm) and hit the calculate button.

FAQs on Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate

What is the formula to find Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate?
The formula of Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate is expressed as Column Performance = (Gas Film Transfer Coefficient*Interfacial Area per Volume)/Molar Gas Flowrate. Here is an example- 1.661013 = (18.8741369*0.1788089)/2.0318103.
How to calculate Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate?
With Gas Film Transfer Coefficient (k'g), Interfacial Area per Volume (a) & Molar Gas Flowrate (Gm) we can find Performance of Column Given Gas-Film Transfer Coefficient and Vapor Flowrate using the formula - Column Performance = (Gas Film Transfer Coefficient*Interfacial Area per Volume)/Molar Gas Flowrate.
What are the other ways to Calculate Column Performance?
Here are the different ways to Calculate Column Performance-
  • Column Performance=1/Height of Transfer UnitOpenImg
Copied!