All Day Efficiency is the ratio of output in kWh to the input in kWh of a transformer over a 24-hour period is known as all day efficiency. Check FAQs
all day=(EoutEin)100
all day - All Day Efficiency?Eout - Output Energy?Ein - Input Energy?

Percentage All Day Efficiency of Transformer Example

With values
With units
Only example

Here is how the Percentage All Day Efficiency of Transformer equation looks like with Values.

Here is how the Percentage All Day Efficiency of Transformer equation looks like with Units.

Here is how the Percentage All Day Efficiency of Transformer equation looks like.

89.2857Edit=(31.25Edit35Edit)100
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Percentage All Day Efficiency of Transformer

Percentage All Day Efficiency of Transformer Solution

Follow our step by step solution on how to calculate Percentage All Day Efficiency of Transformer?

FIRST Step Consider the formula
all day=(EoutEin)100
Next Step Substitute values of Variables
all day=(31.25kW*h35kW*h)100
Next Step Convert Units
all day=(1.1E+8J1.3E+8J)100
Next Step Prepare to Evaluate
all day=(1.1E+81.3E+8)100
Next Step Evaluate
all day=89.2857142857143
LAST Step Rounding Answer
all day=89.2857

Percentage All Day Efficiency of Transformer Formula Elements

Variables
All Day Efficiency
All Day Efficiency is the ratio of output in kWh to the input in kWh of a transformer over a 24-hour period is known as all day efficiency.
Symbol: all day
Measurement: NAUnit: Unitless
Note: Value should be between 0 to 100.
Output Energy
Output Energy is the energy delivered by the device over a period of time.
Symbol: Eout
Measurement: EnergyUnit: kW*h
Note: Value should be greater than 0.
Input Energy
Input energy is defined as the work done on a machine.
Symbol: Ein
Measurement: EnergyUnit: kW*h
Note: Value should be greater than 0.

Other formulas in Transformer Design category

​Go Percentage Regulation of Transformer
%=(Vno-load-Vfull-loadVno-load)100
​Go Utilisation Factor of Transformer Core
UF=AnetAtotal
​Go Voltage Regulation at Lagging PF
%=(I2R2cos(φ2)+I2X2sin(φ2)V2)100
​Go Voltage Regulation at Leading PF
%=(I2R2cos(φ2)-I2X2sin(φ2)V2)100

How to Evaluate Percentage All Day Efficiency of Transformer?

Percentage All Day Efficiency of Transformer evaluator uses All Day Efficiency = ((Output Energy)/(Input Energy))*100 to evaluate the All Day Efficiency, Percentage All Day Efficiency of Transformer is computed on the basis of energy consumed during a period of 24 hours. It can be defined as the ratio of output to input in kWh for 24 hours. All Day Efficiency is denoted by all day symbol.

How to evaluate Percentage All Day Efficiency of Transformer using this online evaluator? To use this online evaluator for Percentage All Day Efficiency of Transformer, enter Output Energy (Eout) & Input Energy (Ein) and hit the calculate button.

FAQs on Percentage All Day Efficiency of Transformer

What is the formula to find Percentage All Day Efficiency of Transformer?
The formula of Percentage All Day Efficiency of Transformer is expressed as All Day Efficiency = ((Output Energy)/(Input Energy))*100. Here is an example- 89.28571 = ((112500000)/(126000000))*100.
How to calculate Percentage All Day Efficiency of Transformer?
With Output Energy (Eout) & Input Energy (Ein) we can find Percentage All Day Efficiency of Transformer using the formula - All Day Efficiency = ((Output Energy)/(Input Energy))*100.
Copied!