Peak Discharge Formula

Fx Copy
LaTeX Copy
Peak Discharge is the maximum volume flow rate passing a particular location during an event. Check FAQs
Qp=2.08ATp
Qp - Peak Discharge?A - Area of Catchment?Tp - Time of Peak?

Peak Discharge Example

With values
With units
Only example

Here is how the Peak Discharge equation looks like with Values.

Here is how the Peak Discharge equation looks like with Units.

Here is how the Peak Discharge equation looks like.

0.8914Edit=2.083Edit7Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Peak Discharge

Peak Discharge Solution

Follow our step by step solution on how to calculate Peak Discharge?

FIRST Step Consider the formula
Qp=2.08ATp
Next Step Substitute values of Variables
Qp=2.083km²7h
Next Step Prepare to Evaluate
Qp=2.0837
Next Step Evaluate
Qp=0.891428571428571m³/s
LAST Step Rounding Answer
Qp=0.8914m³/s

Peak Discharge Formula Elements

Variables
Peak Discharge
Peak Discharge is the maximum volume flow rate passing a particular location during an event.
Symbol: Qp
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Area of Catchment
Area of Catchment is the geographical area from which water flows into a particular point, such as a well, stream, or reservoir.
Symbol: A
Measurement: AreaUnit: km²
Note: Value should be greater than 0.
Time of Peak
Time of Peak is the time interval from the start of rainfall to the peak discharge.
Symbol: Tp
Measurement: TimeUnit: h
Note: Value should be greater than 0.

Other formulas in SCS Triangular Unit Hydrograph category

​Go Time of Peak or Time of Rise
Tp=(tr2)+tp
​Go Lag Time given Time of Peak
tp=Tp-tr2
​Go Time of Recession as Suggested in SCS
Tc=1.67Tp
​Go Time of Peak given Time of Recession
Tp=Tc1.67

How to Evaluate Peak Discharge?

Peak Discharge evaluator uses Peak Discharge = 2.08*Area of Catchment/Time of Peak to evaluate the Peak Discharge, The Peak Discharge formula is defined as the maximum volume flow rate passing a particular location during a storm event. Peak Discharge is denoted by Qp symbol.

How to evaluate Peak Discharge using this online evaluator? To use this online evaluator for Peak Discharge, enter Area of Catchment (A) & Time of Peak (Tp) and hit the calculate button.

FAQs on Peak Discharge

What is the formula to find Peak Discharge?
The formula of Peak Discharge is expressed as Peak Discharge = 2.08*Area of Catchment/Time of Peak. Here is an example- 0.891429 = 2.08*3000000/25200.
How to calculate Peak Discharge?
With Area of Catchment (A) & Time of Peak (Tp) we can find Peak Discharge using the formula - Peak Discharge = 2.08*Area of Catchment/Time of Peak.
Can the Peak Discharge be negative?
Yes, the Peak Discharge, measured in Volumetric Flow Rate can be negative.
Which unit is used to measure Peak Discharge?
Peak Discharge is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Peak Discharge can be measured.
Copied!