P.U. Primary Resistance Drop Formula

Fx Copy
LaTeX Copy
P U Primary Resistance drop is defined as the resistance drop at rated current and frequency expressed at rated voltage. Check FAQs
Rpu=I1R01E1
Rpu - P U Primary Resistance drop?I1 - Primary Current?R01 - Equivalent Resistance from Primary?E1 - EMF Induced in Primary?

P.U. Primary Resistance Drop Example

With values
With units
Only example

Here is how the P.U. Primary Resistance Drop equation looks like with Values.

Here is how the P.U. Primary Resistance Drop equation looks like with Units.

Here is how the P.U. Primary Resistance Drop equation looks like.

34.335Edit=12.6Edit35.97Edit13.2Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx P.U. Primary Resistance Drop

P.U. Primary Resistance Drop Solution

Follow our step by step solution on how to calculate P.U. Primary Resistance Drop?

FIRST Step Consider the formula
Rpu=I1R01E1
Next Step Substitute values of Variables
Rpu=12.6A35.97Ω13.2V
Next Step Prepare to Evaluate
Rpu=12.635.9713.2
LAST Step Evaluate
Rpu=34.335

P.U. Primary Resistance Drop Formula Elements

Variables
P U Primary Resistance drop
P U Primary Resistance drop is defined as the resistance drop at rated current and frequency expressed at rated voltage.
Symbol: Rpu
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Primary Current
Primary Current is the current which is flow in the primary winding of the transformer. The primary current of the transformer is dictated by the load current.
Symbol: I1
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Equivalent Resistance from Primary
The Equivalent Resistance from Primary side is the total resistance of the primary side.
Symbol: R01
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
EMF Induced in Primary
EMF Induced in Primary Winding is the production of voltage in a coil because of the change in magnetic flux through a coil.
Symbol: E1
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.

Other formulas in Resistance category

​Go Equivalent Reactance of Transformer from Primary Side
X01=XL1+X'2
​Go Equivalent Reactance of Transformer from Secondary Side
X02=XL2+X'1
​Go Primary Leakage Reactance
XL1=X'1K2
​Go Reactance of Primary Winding in Secondary
X'1=XL1K2

How to Evaluate P.U. Primary Resistance Drop?

P.U. Primary Resistance Drop evaluator uses P U Primary Resistance drop = (Primary Current*Equivalent Resistance from Primary)/EMF Induced in Primary to evaluate the P U Primary Resistance drop, P.U. Primary Resistance drop is defined as the resistance drop at rated current and frequency expressed at rated voltage. P U Primary Resistance drop is denoted by Rpu symbol.

How to evaluate P.U. Primary Resistance Drop using this online evaluator? To use this online evaluator for P.U. Primary Resistance Drop, enter Primary Current (I1), Equivalent Resistance from Primary (R01) & EMF Induced in Primary (E1) and hit the calculate button.

FAQs on P.U. Primary Resistance Drop

What is the formula to find P.U. Primary Resistance Drop?
The formula of P.U. Primary Resistance Drop is expressed as P U Primary Resistance drop = (Primary Current*Equivalent Resistance from Primary)/EMF Induced in Primary. Here is an example- 34.335 = (12.6*35.97)/13.2.
How to calculate P.U. Primary Resistance Drop?
With Primary Current (I1), Equivalent Resistance from Primary (R01) & EMF Induced in Primary (E1) we can find P.U. Primary Resistance Drop using the formula - P U Primary Resistance drop = (Primary Current*Equivalent Resistance from Primary)/EMF Induced in Primary.
Copied!