Partial pressure of water vapor at wet bulb temperature Formula

Fx Copy
LaTeX Copy
Partial pressure of the water vapor at wet bulb temperature. Check FAQs
Pw=(hConv(T∞-Tw)hfgkL)+P∞
Pw - Partial Pressure?hConv - Convective Heat Transfer Coefficient?T∞ - Air Temperature?Tw - Wet Bulb Temperature?hfg - Enthalpy of Evaporation?kL - Convective Mass Transfer Coefficient?P∞ - Partial Pressure in air?

Partial pressure of water vapor at wet bulb temperature Example

With values
With units
Only example

Here is how the Partial pressure of water vapor at wet bulb temperature equation looks like with Values.

Here is how the Partial pressure of water vapor at wet bulb temperature equation looks like with Units.

Here is how the Partial pressure of water vapor at wet bulb temperature equation looks like.

12.2967Edit=(0.5Edit(35Edit-14Edit)90Edit0.0095Edit)+0.016Edit
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Partial pressure of water vapor at wet bulb temperature

Partial pressure of water vapor at wet bulb temperature Solution

Follow our step by step solution on how to calculate Partial pressure of water vapor at wet bulb temperature?

FIRST Step Consider the formula
Pw=(hConv(T∞-Tw)hfgkL)+P∞
Next Step Substitute values of Variables
Pw=(0.5W/m²*K(35-14)90J/kg*K0.0095m/s)+0.016
Next Step Prepare to Evaluate
Pw=(0.5(35-14)900.0095)+0.016
Next Step Evaluate
Pw=12.296701754386
LAST Step Rounding Answer
Pw=12.2967

Partial pressure of water vapor at wet bulb temperature Formula Elements

Variables
Partial Pressure
Partial pressure of the water vapor at wet bulb temperature.
Symbol: Pw
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Convective Heat Transfer Coefficient
Convective Heat Transfer Coefficient is the heat transfer due to convection.
Symbol: hConv
Measurement: Heat Transfer CoefficientUnit: W/m²*K
Note: Value can be positive or negative.
Air Temperature
Air temperature is the temperature of the air surrounding an individual and is typically measured in degrees Celsius (°C) or in Kelvin.
Symbol: T∞
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Wet Bulb Temperature
Wet Bulb Temperature is the temperature of the wet bulb and denoted by the symbol Tw.
Symbol: Tw
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Enthalpy of Evaporation
Enthalpy of evaporation is the amount of energy (enthalpy) that must be added to a liquid substance to transform a quantity of that substance into a gas.
Symbol: hfg
Measurement: Specific EntropyUnit: J/kg*K
Note: Value can be positive or negative.
Convective Mass Transfer Coefficient
Convective Mass Transfer Coefficient is a function of geometry of the system and the velocity and properties of the fluid similar to the heat transfer coefficient.
Symbol: kL
Measurement: SpeedUnit: m/s
Note: Value can be positive or negative.
Partial Pressure in air
Partial pressure in air of the water vapor is the pressure of water in the mixture of water and air.
Symbol: P∞
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Humidification category

​Go Enthalpy of evaporation for water in humidification
hfg=hConv(T∞-Tw)kL(Pw-P∞)
​Go Convective mass transfer coefficient in humidification
kL=hConv(T∞-Tw)hfg(Pw-P∞)

How to Evaluate Partial pressure of water vapor at wet bulb temperature?

Partial pressure of water vapor at wet bulb temperature evaluator uses Partial Pressure = ((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))+Partial Pressure in air to evaluate the Partial Pressure, The Partial pressure of water vapor at wet bulb temperature formula is defined as the pressure of the water vapor at wet bulb temerature. Partial Pressure is denoted by Pw symbol.

How to evaluate Partial pressure of water vapor at wet bulb temperature using this online evaluator? To use this online evaluator for Partial pressure of water vapor at wet bulb temperature, enter Convective Heat Transfer Coefficient (hConv), Air Temperature (T∞), Wet Bulb Temperature (Tw), Enthalpy of Evaporation (hfg), Convective Mass Transfer Coefficient (kL) & Partial Pressure in air (P∞) and hit the calculate button.

FAQs on Partial pressure of water vapor at wet bulb temperature

What is the formula to find Partial pressure of water vapor at wet bulb temperature?
The formula of Partial pressure of water vapor at wet bulb temperature is expressed as Partial Pressure = ((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))+Partial Pressure in air. Here is an example- 13.83179 = ((0.5*(35-14))/(90*0.0095))+0.016.
How to calculate Partial pressure of water vapor at wet bulb temperature?
With Convective Heat Transfer Coefficient (hConv), Air Temperature (T∞), Wet Bulb Temperature (Tw), Enthalpy of Evaporation (hfg), Convective Mass Transfer Coefficient (kL) & Partial Pressure in air (P∞) we can find Partial pressure of water vapor at wet bulb temperature using the formula - Partial Pressure = ((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))+Partial Pressure in air.
Copied!