Fx Copy
LaTeX Copy
Oxygen Transferred is the amount of oxygen that is moved from the air into the water. Check FAQs
N=Ns(DO0.85-DL)0.85(1.024)T-209.17
N - Oxygen Transferred?Ns - Oxygen Transfer Capacity?DO0.85 - D.O Saturation when Correction Factor is 0.85?DL - Operation Dissolved Oxygen?T - Temperature?

Oxygen Transferred under Field Conditions when Correction Factor is 0.85 Example

With values
With units
Only example

Here is how the Oxygen Transferred under Field Conditions when Correction Factor is 0.85 equation looks like with Values.

Here is how the Oxygen Transferred under Field Conditions when Correction Factor is 0.85 equation looks like with Units.

Here is how the Oxygen Transferred under Field Conditions when Correction Factor is 0.85 equation looks like.

3Edit=2.03Edit(3414.55Edit-2.01Edit)0.85(1.024)85Edit-209.17
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Oxygen Transferred under Field Conditions when Correction Factor is 0.85

Oxygen Transferred under Field Conditions when Correction Factor is 0.85 Solution

Follow our step by step solution on how to calculate Oxygen Transferred under Field Conditions when Correction Factor is 0.85?

FIRST Step Consider the formula
N=Ns(DO0.85-DL)0.85(1.024)T-209.17
Next Step Substitute values of Variables
N=2.03kg/h/kW(3414.55mg/L-2.01mg/L)0.85(1.024)85K-209.17
Next Step Convert Units
N=5.6E-7kg/s/W(3.4146kg/m³-0.002kg/m³)0.85(1.024)85K-209.17
Next Step Prepare to Evaluate
N=5.6E-7(3.4146-0.002)0.85(1.024)85-209.17
Next Step Evaluate
N=8.33332000666969E-07kg/s/W
Next Step Convert to Output's Unit
N=2.99999520240109kg/h/kW
LAST Step Rounding Answer
N=3kg/h/kW

Oxygen Transferred under Field Conditions when Correction Factor is 0.85 Formula Elements

Variables
Oxygen Transferred
Oxygen Transferred is the amount of oxygen that is moved from the air into the water.
Symbol: N
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Oxygen Transfer Capacity
Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water.
Symbol: Ns
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
D.O Saturation when Correction Factor is 0.85
D.O Saturation when Correction Factor is 0.85 is the maximum concentration of dissolved oxygen, when the actual D.O. saturation level in sewage is 85% of the theoretical D.O. saturation level.
Symbol: DO0.85
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Operation Dissolved Oxygen
Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms.
Symbol: DL
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Temperature
Temperature is the degree or intensity of heat present in a substance or object.
Symbol: T
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.

Other Formulas to find Oxygen Transferred

​Go Oxygen Transferred under Field Conditions
N=Ns(DS-DL)Cf(1.024)T-209.17
​Go Oxygen Transferred under Field given Difference between Saturation and Operation Dissolved Oxygen
N=NsDCf(1.024)T-209.17
​Go Oxygen Transferred under Field Conditions when Correction Factor is 0.8
N=Ns(DO0.8-DL)0.8(1.024)T-209.17

Other formulas in Oxygen Transfer Capacity category

​Go Oxygen Transfer Capacity under Standard Conditions
Ns=N(DS-DL)Cf(1.024)T-209.17
​Go Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen
Ns=NDCf(1.024)T-209.17
​Go Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8
Ns=N(DO0.8-DL)0.8(1.024)T-209.17
​Go Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.85
Ns=N(DO0.85-DL)0.85(1.024)T-209.17

How to Evaluate Oxygen Transferred under Field Conditions when Correction Factor is 0.85?

Oxygen Transferred under Field Conditions when Correction Factor is 0.85 evaluator uses Oxygen Transferred = (Oxygen Transfer Capacity*(D.O Saturation when Correction Factor is 0.85-Operation Dissolved Oxygen)*0.85*(1.024)^(Temperature-20))/(9.17) to evaluate the Oxygen Transferred, The Oxygen Transferred under Field Conditions when Correction Factor is 0.85 formula is defined as the calculation of the oxygen transferred under field condition when we correction factor is 0.85. Oxygen Transferred is denoted by N symbol.

How to evaluate Oxygen Transferred under Field Conditions when Correction Factor is 0.85 using this online evaluator? To use this online evaluator for Oxygen Transferred under Field Conditions when Correction Factor is 0.85, enter Oxygen Transfer Capacity (Ns), D.O Saturation when Correction Factor is 0.85 (DO0.85), Operation Dissolved Oxygen (DL) & Temperature (T) and hit the calculate button.

FAQs on Oxygen Transferred under Field Conditions when Correction Factor is 0.85

What is the formula to find Oxygen Transferred under Field Conditions when Correction Factor is 0.85?
The formula of Oxygen Transferred under Field Conditions when Correction Factor is 0.85 is expressed as Oxygen Transferred = (Oxygen Transfer Capacity*(D.O Saturation when Correction Factor is 0.85-Operation Dissolved Oxygen)*0.85*(1.024)^(Temperature-20))/(9.17). Here is an example- 1.1E+7 = (5.63888888888889E-07*(3.41455-0.00201)*0.85*(1.024)^(85-20))/(9.17).
How to calculate Oxygen Transferred under Field Conditions when Correction Factor is 0.85?
With Oxygen Transfer Capacity (Ns), D.O Saturation when Correction Factor is 0.85 (DO0.85), Operation Dissolved Oxygen (DL) & Temperature (T) we can find Oxygen Transferred under Field Conditions when Correction Factor is 0.85 using the formula - Oxygen Transferred = (Oxygen Transfer Capacity*(D.O Saturation when Correction Factor is 0.85-Operation Dissolved Oxygen)*0.85*(1.024)^(Temperature-20))/(9.17).
What are the other ways to Calculate Oxygen Transferred?
Here are the different ways to Calculate Oxygen Transferred-
  • Oxygen Transferred=(Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17)OpenImg
  • Oxygen Transferred=(Oxygen Transfer Capacity*Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)OpenImg
  • Oxygen Transferred=(Oxygen Transfer Capacity*(D.O Saturation when Correction Factor is 0.8-Operation Dissolved Oxygen)*0.8*(1.024)^(Temperature-20))/(9.17)OpenImg
Can the Oxygen Transferred under Field Conditions when Correction Factor is 0.85 be negative?
No, the Oxygen Transferred under Field Conditions when Correction Factor is 0.85, measured in Specific Fuel Consumption cannot be negative.
Which unit is used to measure Oxygen Transferred under Field Conditions when Correction Factor is 0.85?
Oxygen Transferred under Field Conditions when Correction Factor is 0.85 is usually measured using the Kilogram per Hour per Kilowatt[kg/h/kW] for Specific Fuel Consumption. Kilogram per Second per Watt[kg/h/kW], Kilogram per Hour per Watt[kg/h/kW], Kilogram per Second per Brake horsepower[kg/h/kW] are the few other units in which Oxygen Transferred under Field Conditions when Correction Factor is 0.85 can be measured.
Copied!