Fx Copy
LaTeX Copy
Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water. Check FAQs
Ns=NDCf(1.024)T-209.17
Ns - Oxygen Transfer Capacity?N - Oxygen Transferred?D - Difference between Saturation DO and Operation DO?Cf - Correction Factor?T - Temperature?

Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen Example

With values
With units
Only example

Here is how the Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen equation looks like with Values.

Here is how the Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen equation looks like with Units.

Here is how the Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen equation looks like.

1.7843Edit=3Edit6600Edit0.5Edit(1.024)85Edit-209.17
You are here -

Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen Solution

Follow our step by step solution on how to calculate Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen?

FIRST Step Consider the formula
Ns=NDCf(1.024)T-209.17
Next Step Substitute values of Variables
Ns=3kg/h/kW6600mg/L0.5(1.024)85K-209.17
Next Step Convert Units
Ns=8.3E-7kg/s/W6.6kg/m³0.5(1.024)85K-209.17
Next Step Prepare to Evaluate
Ns=8.3E-76.60.5(1.024)85-209.17
Next Step Evaluate
Ns=4.95652120087768E-07kg/s/W
Next Step Convert to Output's Unit
Ns=1.78434763231596kg/h/kW
LAST Step Rounding Answer
Ns=1.7843kg/h/kW

Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen Formula Elements

Variables
Oxygen Transfer Capacity
Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water.
Symbol: Ns
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Oxygen Transferred
Oxygen Transferred is the amount of oxygen that is moved from the air into the water.
Symbol: N
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Difference between Saturation DO and Operation DO
Difference between Saturation DO and Operation DO is the value obtained after subtracting operation DO from saturation DO.
Symbol: D
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Correction Factor
Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error.
Symbol: Cf
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Temperature
Temperature is the degree or intensity of heat present in a substance or object.
Symbol: T
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.

Other Formulas to find Oxygen Transfer Capacity

​Go Oxygen Transfer Capacity under Standard Conditions
Ns=N(DS-DL)Cf(1.024)T-209.17
​Go Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8
Ns=N(DO0.8-DL)0.8(1.024)T-209.17
​Go Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.85
Ns=N(DO0.85-DL)0.85(1.024)T-209.17

Other formulas in Oxygen Transfer Capacity category

​Go Oxygen Transferred under Field Conditions
N=Ns(DS-DL)Cf(1.024)T-209.17
​Go Oxygen Transferred under Field given Difference between Saturation and Operation Dissolved Oxygen
N=NsDCf(1.024)T-209.17
​Go Oxygen Transferred under Field Conditions when Correction Factor is 0.8
N=Ns(DO0.8-DL)0.8(1.024)T-209.17
​Go Oxygen Transferred under Field Conditions when Correction Factor is 0.85
N=Ns(DO0.85-DL)0.85(1.024)T-209.17

How to Evaluate Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen?

Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen evaluator uses Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)) to evaluate the Oxygen Transfer Capacity, The Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen formula is defined as the calculation of the oxygen transfer capacity when we have prior information of difference between saturation and operation dissolved oxygen. Oxygen Transfer Capacity is denoted by Ns symbol.

How to evaluate Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen using this online evaluator? To use this online evaluator for Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen, enter Oxygen Transferred (N), Difference between Saturation DO and Operation DO (D), Correction Factor (Cf) & Temperature (T) and hit the calculate button.

FAQs on Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen

What is the formula to find Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen?
The formula of Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen is expressed as Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)). Here is an example- 7.3E+6 = 8.33333333333333E-07/((6.6*0.5*(1.024)^(85-20))/(9.17)).
How to calculate Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen?
With Oxygen Transferred (N), Difference between Saturation DO and Operation DO (D), Correction Factor (Cf) & Temperature (T) we can find Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen using the formula - Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)).
What are the other ways to Calculate Oxygen Transfer Capacity?
Here are the different ways to Calculate Oxygen Transfer Capacity-
  • Oxygen Transfer Capacity=Oxygen Transferred/(((Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17))OpenImg
  • Oxygen Transfer Capacity=Oxygen Transferred/(((D.O Saturation when Correction Factor is 0.8-Operation Dissolved Oxygen)*0.8*(1.024)^(Temperature-20))/(9.17))OpenImg
  • Oxygen Transfer Capacity=Oxygen Transferred/(((D.O Saturation when Correction Factor is 0.85-Operation Dissolved Oxygen)*0.85*(1.024)^(Temperature-20))/(9.17))OpenImg
Can the Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen be negative?
No, the Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen, measured in Specific Fuel Consumption cannot be negative.
Which unit is used to measure Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen?
Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen is usually measured using the Kilogram per Hour per Kilowatt[kg/h/kW] for Specific Fuel Consumption. Kilogram per Second per Watt[kg/h/kW], Kilogram per Hour per Watt[kg/h/kW], Kilogram per Second per Brake horsepower[kg/h/kW] are the few other units in which Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen can be measured.
Copied!