Overall Tray Efficiency for Absorption Column given Murphree Efficiency Formula

Fx Copy
LaTeX Copy
Overall Tray Efficiency of Absorption Column is defined as the ratio of number of Ideal Plates to the number of Actual Plates or can be calculated from Murphree Efficiency. Check FAQs
EO=(ln(1+(EMG100)((1A)-1))ln(1A))100
EO - Overall Tray Efficiency of Absorption Column?EMG - Murphree Efficiency of Absorption Column?A - Absorption Factor?

Overall Tray Efficiency for Absorption Column given Murphree Efficiency Example

With values
With units
Only example

Here is how the Overall Tray Efficiency for Absorption Column given Murphree Efficiency equation looks like with Values.

Here is how the Overall Tray Efficiency for Absorption Column given Murphree Efficiency equation looks like with Units.

Here is how the Overall Tray Efficiency for Absorption Column given Murphree Efficiency equation looks like.

56.7041Edit=(ln(1+(65Edit100)((12Edit)-1))ln(12Edit))100
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Overall Tray Efficiency for Absorption Column given Murphree Efficiency

Overall Tray Efficiency for Absorption Column given Murphree Efficiency Solution

Follow our step by step solution on how to calculate Overall Tray Efficiency for Absorption Column given Murphree Efficiency?

FIRST Step Consider the formula
EO=(ln(1+(EMG100)((1A)-1))ln(1A))100
Next Step Substitute values of Variables
EO=(ln(1+(65100)((12)-1))ln(12))100
Next Step Prepare to Evaluate
EO=(ln(1+(65100)((12)-1))ln(12))100
Next Step Evaluate
EO=56.7040592723894
LAST Step Rounding Answer
EO=56.7041

Overall Tray Efficiency for Absorption Column given Murphree Efficiency Formula Elements

Variables
Functions
Overall Tray Efficiency of Absorption Column
Overall Tray Efficiency of Absorption Column is defined as the ratio of number of Ideal Plates to the number of Actual Plates or can be calculated from Murphree Efficiency.
Symbol: EO
Measurement: NAUnit: Unitless
Note: Value should be less than 100.
Murphree Efficiency of Absorption Column
Murphree Efficiency of Absorption Column is defined for each tray according to the separation achieved on each tray based on either the liquid phase or the vapor phase.
Symbol: EMG
Measurement: NAUnit: Unitless
Note: Value should be less than 100.
Absorption Factor
The Absorption Factor is the ratio of slopes of operating line of absorption to the equilibrium line. If equilibrium line is a curve then the absorption factor is the average at the two ends.
Symbol: A
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
ln
The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function.
Syntax: ln(Number)

Other formulas in Gas Absorption and Stripping category

​Go Number of Stripping Stages by Kremser Equation
N=log10((X0(Stripping)-(YN+1(Stripping)α)XN(Stripping)-(YN+1(Stripping)α))(1-(1S))+(1S))log10(S)
​Go Stripping Factor
S=αGs(Stripping)Ls(Stripping)
​Go Stripping Factor given Absorption Factor
S=1A
​Go Absorption Factor
A=LsαGs

How to Evaluate Overall Tray Efficiency for Absorption Column given Murphree Efficiency?

Overall Tray Efficiency for Absorption Column given Murphree Efficiency evaluator uses Overall Tray Efficiency of Absorption Column = (ln(1+(Murphree Efficiency of Absorption Column/100)*((1/Absorption Factor)-1))/ln(1/Absorption Factor))*100 to evaluate the Overall Tray Efficiency of Absorption Column, The Overall Tray Efficiency for Absorption Column given Murphree Efficiency formula is defined as overall tray efficiency or overall column efficiency in a section of column which is used to determine the number of real trays. Overall Tray Efficiency of Absorption Column is denoted by EO symbol.

How to evaluate Overall Tray Efficiency for Absorption Column given Murphree Efficiency using this online evaluator? To use this online evaluator for Overall Tray Efficiency for Absorption Column given Murphree Efficiency, enter Murphree Efficiency of Absorption Column (EMG) & Absorption Factor (A) and hit the calculate button.

FAQs on Overall Tray Efficiency for Absorption Column given Murphree Efficiency

What is the formula to find Overall Tray Efficiency for Absorption Column given Murphree Efficiency?
The formula of Overall Tray Efficiency for Absorption Column given Murphree Efficiency is expressed as Overall Tray Efficiency of Absorption Column = (ln(1+(Murphree Efficiency of Absorption Column/100)*((1/Absorption Factor)-1))/ln(1/Absorption Factor))*100. Here is an example- 56.70406 = (ln(1+(65/100)*((1/2)-1))/ln(1/2))*100.
How to calculate Overall Tray Efficiency for Absorption Column given Murphree Efficiency?
With Murphree Efficiency of Absorption Column (EMG) & Absorption Factor (A) we can find Overall Tray Efficiency for Absorption Column given Murphree Efficiency using the formula - Overall Tray Efficiency of Absorption Column = (ln(1+(Murphree Efficiency of Absorption Column/100)*((1/Absorption Factor)-1))/ln(1/Absorption Factor))*100. This formula also uses Natural Logarithm (ln) function(s).
Copied!