Output Switching at Load Power Consumption Formula

Fx Copy
LaTeX Copy
Output switching defined as number of bits changed when switching is done in the whole process and calculated accordingly for the finding out the total output switching. Check FAQs
Swo=PLCLVcc2fo
Swo - Output Switching?PL - Capacitive Load Power Consumption?CL - External Load Capacitance?Vcc - Supply Voltage?fo - Output Signal Frequency?

Output Switching at Load Power Consumption Example

With values
With units
Only example

Here is how the Output Switching at Load Power Consumption equation looks like with Values.

Here is how the Output Switching at Load Power Consumption equation looks like with Units.

Here is how the Output Switching at Load Power Consumption equation looks like.

4.0042Edit=2.94Edit5.01Edit1.55Edit261Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category CMOS Design and Applications » fx Output Switching at Load Power Consumption

Output Switching at Load Power Consumption Solution

Follow our step by step solution on how to calculate Output Switching at Load Power Consumption?

FIRST Step Consider the formula
Swo=PLCLVcc2fo
Next Step Substitute values of Variables
Swo=2.94mW5.01μF1.55V261Hz
Next Step Convert Units
Swo=0.0029W5E-6F1.55V261Hz
Next Step Prepare to Evaluate
Swo=0.00295E-61.55261
Next Step Evaluate
Swo=4.00420564170102
LAST Step Rounding Answer
Swo=4.0042

Output Switching at Load Power Consumption Formula Elements

Variables
Output Switching
Output switching defined as number of bits changed when switching is done in the whole process and calculated accordingly for the finding out the total output switching.
Symbol: Swo
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Capacitive Load Power Consumption
The Capacitive Load Power Consumption is to calculate the power consumption of the capacitor.
Symbol: PL
Measurement: PowerUnit: mW
Note: Value should be greater than 0.
External Load Capacitance
The External Load Capacitance is calculated by the load capacitor(which is connected outside the circuit) of a circuit.
Symbol: CL
Measurement: CapacitanceUnit: μF
Note: Value should be greater than 0.
Supply Voltage
The Supply voltage is the voltage input.
Symbol: Vcc
Measurement: Electric PotentialUnit: V
Note: Value should be between 0 to 1000.
Output Signal Frequency
The Output Signal Frequency is calculated by taking frequency at the output of the signal.
Symbol: fo
Measurement: FrequencyUnit: Hz
Note: Value should be greater than 0.

Other formulas in CMOS Power Metrics category

​Go Activity Factor
α=PsCVbc2f
​Go Switching Power
Ps=α(CVbc2f)
​Go Dynamic Power in CMOS
Pdyn=Psc+Ps
​Go Short-Circuit Power in CMOS
Psc=Pdyn-Ps

How to Evaluate Output Switching at Load Power Consumption?

Output Switching at Load Power Consumption evaluator uses Output Switching = Capacitive Load Power Consumption/(External Load Capacitance*Supply Voltage^2*Output Signal Frequency) to evaluate the Output Switching, Output Switching at Load Power Consumption refers to the ability of a power load to switch between different electrical outputs based on the load's power requirements. Output Switching is denoted by Swo symbol.

How to evaluate Output Switching at Load Power Consumption using this online evaluator? To use this online evaluator for Output Switching at Load Power Consumption, enter Capacitive Load Power Consumption (PL), External Load Capacitance (CL), Supply Voltage (Vcc) & Output Signal Frequency (fo) and hit the calculate button.

FAQs on Output Switching at Load Power Consumption

What is the formula to find Output Switching at Load Power Consumption?
The formula of Output Switching at Load Power Consumption is expressed as Output Switching = Capacitive Load Power Consumption/(External Load Capacitance*Supply Voltage^2*Output Signal Frequency). Here is an example- 4.004206 = 0.00294/(5.01E-06*1.55^2*61).
How to calculate Output Switching at Load Power Consumption?
With Capacitive Load Power Consumption (PL), External Load Capacitance (CL), Supply Voltage (Vcc) & Output Signal Frequency (fo) we can find Output Switching at Load Power Consumption using the formula - Output Switching = Capacitive Load Power Consumption/(External Load Capacitance*Supply Voltage^2*Output Signal Frequency).
Copied!