Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load Formula

Fx Copy
LaTeX Copy
DC Power Output SP is the product of current and voltage at the output terminal of a rectifier. It is also defined as rate at which electrical energy is transferred in an electrical circuit. Check FAQs
P(dc)=V(max)Imaxπ2
P(dc) - DC Power Output SP?V(max) - Peak Input Voltage SP?Imax - Peak Load Current?π - Archimedes' constant?

Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load Example

With values
With units
Only example

Here is how the Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load equation looks like with Values.

Here is how the Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load equation looks like with Units.

Here is how the Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load equation looks like.

108.6011Edit=221Edit4.85Edit3.14162
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load

Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load Solution

Follow our step by step solution on how to calculate Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load?

FIRST Step Consider the formula
P(dc)=V(max)Imaxπ2
Next Step Substitute values of Variables
P(dc)=221V4.85Aπ2
Next Step Substitute values of Constants
P(dc)=221V4.85A3.14162
Next Step Prepare to Evaluate
P(dc)=2214.853.14162
Next Step Evaluate
P(dc)=108.60111068704W
LAST Step Rounding Answer
P(dc)=108.6011W

Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load Formula Elements

Variables
Constants
DC Power Output SP
DC Power Output SP is the product of current and voltage at the output terminal of a rectifier. It is also defined as rate at which electrical energy is transferred in an electrical circuit.
Symbol: P(dc)
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Peak Input Voltage SP
Peak Input Voltage SP is the peak of the alternating voltage provided at the input of any electrical circuit.
Symbol: V(max)
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Peak Load Current
Peak load current is defined as the root mean square value of the output current.
Symbol: Imax
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288

Other formulas in Half Wave category

​Go Average Output Voltage of Single Phase Half Wave Diode Rectifier with Resistive Load
Vdc(h)=V(max)π
​Go RMS Output Voltage of Single Phase Half Wave Diode Rectifier with Resistive Load
Vrms(h)=V(max)2
​Go Average Load Current of Single Phase Half Wave Diode Rectifier with Resistive Load
IL=V(max)πr
​Go RMS Load Current of Single Phase Half Wave Diode Rectifier with Resistive Load
ILrms=V(max)2r

How to Evaluate Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load?

Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load evaluator uses DC Power Output SP = (Peak Input Voltage SP*Peak Load Current)/pi^2 to evaluate the DC Power Output SP, The Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load formula is defined as is the average amount of electrical power delivered to a load over a complete AC cycle. In a half-wave rectifier, only one half of the input AC waveform is utilized, resulting in lower average power output compared to a full-wave rectifier. This value represents the steady DC power supplied to the load. DC Power Output SP is denoted by P(dc) symbol.

How to evaluate Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load using this online evaluator? To use this online evaluator for Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load, enter Peak Input Voltage SP (V(max)) & Peak Load Current (Imax) and hit the calculate button.

FAQs on Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load

What is the formula to find Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load?
The formula of Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load is expressed as DC Power Output SP = (Peak Input Voltage SP*Peak Load Current)/pi^2. Here is an example- 108.3772 = (221*4.85)/pi^2.
How to calculate Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load?
With Peak Input Voltage SP (V(max)) & Peak Load Current (Imax) we can find Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load using the formula - DC Power Output SP = (Peak Input Voltage SP*Peak Load Current)/pi^2. This formula also uses Archimedes' constant .
Can the Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load be negative?
No, the Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load, measured in Power cannot be negative.
Which unit is used to measure Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load?
Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Output DC Power of Single-Phase Half Wave Diode Rectifier with R Load can be measured.