Organic Loading to Trickling Filter Formula

Fx Copy
LaTeX Copy
Organic Loading is the amount of organic material, typically measured in kilograms per day per cubic meter that is applied to the filter bed for biological treatment of wastewater. Check FAQs
OL=(BOD5ALf)
OL - Organic Loading?BOD5 - BOD Loading to Filter?A - Area of Filter?Lf - Filter Length?

Organic Loading to Trickling Filter Example

With values
With units
Only example

Here is how the Organic Loading to Trickling Filter equation looks like with Values.

Here is how the Organic Loading to Trickling Filter equation looks like with Units.

Here is how the Organic Loading to Trickling Filter equation looks like.

30Edit=(225Edit3Edit2.5Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Organic Loading to Trickling Filter

Organic Loading to Trickling Filter Solution

Follow our step by step solution on how to calculate Organic Loading to Trickling Filter?

FIRST Step Consider the formula
OL=(BOD5ALf)
Next Step Substitute values of Variables
OL=(225kg/d32.5m)
Next Step Convert Units
OL=(0.0026kg/s32.5m)
Next Step Prepare to Evaluate
OL=(0.002632.5)
Next Step Evaluate
OL=0.000347222222222223kg/s*m²
LAST Step Convert to Output's Unit
OL=30kg/d*m²

Organic Loading to Trickling Filter Formula Elements

Variables
Organic Loading
Organic Loading is the amount of organic material, typically measured in kilograms per day per cubic meter that is applied to the filter bed for biological treatment of wastewater.
Symbol: OL
Measurement: Solid Loading RateUnit: kg/d*m²
Note: Value should be greater than 0.
BOD Loading to Filter
BOD Loading to Filter is the amount of biochemical oxygen demand applied to a filtration system, typically expressed in terms of mass per unit area or volume.
Symbol: BOD5
Measurement: Mass Flow RateUnit: kg/d
Note: Value should be greater than 0.
Area of Filter
The Area of Filter refers to the total surface available for filtration, affecting its capacity and efficiency, typically measured in square meters (m²).
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Filter Length
The Filter Length refers to the total length of filter required to effectively do the filtering process.
Symbol: Lf
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other formulas in Organic Loading category

​Go Filter Length given Organic Loading
Lf=BOD5OLA
​Go Area of Filter given Organic Loading
A=BOD5OLLf
​Go BOD Load given Organic Loading
BOD5=OLALf

How to Evaluate Organic Loading to Trickling Filter?

Organic Loading to Trickling Filter evaluator uses Organic Loading = (BOD Loading to Filter/(Area of Filter*Filter Length)) to evaluate the Organic Loading, The Organic Loading to Trickling Filter is defined as the rate at which organic matter is applied to a trickling filter, typically measured in kilograms per cubic meter per day (kg/m³/day) or other suitable unit. Organic Loading is denoted by OL symbol.

How to evaluate Organic Loading to Trickling Filter using this online evaluator? To use this online evaluator for Organic Loading to Trickling Filter, enter BOD Loading to Filter (BOD5), Area of Filter (A) & Filter Length (Lf) and hit the calculate button.

FAQs on Organic Loading to Trickling Filter

What is the formula to find Organic Loading to Trickling Filter?
The formula of Organic Loading to Trickling Filter is expressed as Organic Loading = (BOD Loading to Filter/(Area of Filter*Filter Length)). Here is an example- 2.2E+6 = (0.00260416666666667/(3*2.5)).
How to calculate Organic Loading to Trickling Filter?
With BOD Loading to Filter (BOD5), Area of Filter (A) & Filter Length (Lf) we can find Organic Loading to Trickling Filter using the formula - Organic Loading = (BOD Loading to Filter/(Area of Filter*Filter Length)).
Can the Organic Loading to Trickling Filter be negative?
No, the Organic Loading to Trickling Filter, measured in Solid Loading Rate cannot be negative.
Which unit is used to measure Organic Loading to Trickling Filter?
Organic Loading to Trickling Filter is usually measured using the kilogram per Day Square Meter[kg/d*m²] for Solid Loading Rate. Kilogram per Second Square Meter[kg/d*m²], Kilogram per Second Square Decameter[kg/d*m²], Kilogram per Second Are[kg/d*m²] are the few other units in which Organic Loading to Trickling Filter can be measured.
Copied!