Operation Dissolved Oxygen Level Formula

Fx Copy
LaTeX Copy
Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms. Check FAQs
DL=DS-(N9.17NsCf(1.024)T-20)
DL - Operation Dissolved Oxygen?DS - Dissolved Oxygen Saturation?N - Oxygen Transferred?Ns - Oxygen Transfer Capacity?Cf - Correction Factor?T - Temperature?

Operation Dissolved Oxygen Level Example

With values
With units
Only example

Here is how the Operation Dissolved Oxygen Level equation looks like with Values.

Here is how the Operation Dissolved Oxygen Level equation looks like with Units.

Here is how the Operation Dissolved Oxygen Level equation looks like.

1.6727Edit=5803Edit-(3Edit9.172.03Edit0.5Edit(1.024)85Edit-20)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Operation Dissolved Oxygen Level

Operation Dissolved Oxygen Level Solution

Follow our step by step solution on how to calculate Operation Dissolved Oxygen Level?

FIRST Step Consider the formula
DL=DS-(N9.17NsCf(1.024)T-20)
Next Step Substitute values of Variables
DL=5803mg/L-(3kg/h/kW9.172.03kg/h/kW0.5(1.024)85K-20)
Next Step Convert Units
DL=5.803kg/m³-(8.3E-7kg/s/W9.175.6E-7kg/s/W0.5(1.024)85K-20)
Next Step Prepare to Evaluate
DL=5.803-(8.3E-79.175.6E-70.5(1.024)85-20)
Next Step Evaluate
DL=0.00167272251952699kg/m³
Next Step Convert to Output's Unit
DL=1.67272251952699mg/L
LAST Step Rounding Answer
DL=1.6727mg/L

Operation Dissolved Oxygen Level Formula Elements

Variables
Operation Dissolved Oxygen
Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms.
Symbol: DL
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Dissolved Oxygen Saturation
Dissolved Oxygen Saturation is the maximum amount of oxygen that can be dissolved in water at a given temperature and pressure.
Symbol: DS
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Oxygen Transferred
Oxygen Transferred is the amount of oxygen that is moved from the air into the water.
Symbol: N
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Oxygen Transfer Capacity
Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water.
Symbol: Ns
Measurement: Specific Fuel ConsumptionUnit: kg/h/kW
Note: Value should be greater than 0.
Correction Factor
Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error.
Symbol: Cf
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Temperature
Temperature is the degree or intensity of heat present in a substance or object.
Symbol: T
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.

Other formulas in Operation D.O Level category

​Go Ratio of BOD to Ultimate BOD
f=BOD5BODu
​Go BOD5 given Oxygen Required in Aeration Tank
BOD5a=BODuQs(Qi-Q)O2+(1.42QwXR)
​Go BOD5 given Ratio of BOD to Ultimate BOD
BOD5r=fBODu
​Go BOD5 when Ratio of BOD to Ultimate BOD is 0.68
BOD5=BODu0.68

How to Evaluate Operation Dissolved Oxygen Level?

Operation Dissolved Oxygen Level evaluator uses Operation Dissolved Oxygen = Dissolved Oxygen Saturation-((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*Correction Factor*(1.024)^(Temperature-20))) to evaluate the Operation Dissolved Oxygen, Operation Dissolved Oxygen Level formula is defined as a measure of the amount of dissolved oxygen present in water, which is essential for the survival of aquatic organisms, and is affected by factors such as temperature, nutrient levels, and oxygen demand from microorganisms. Operation Dissolved Oxygen is denoted by DL symbol.

How to evaluate Operation Dissolved Oxygen Level using this online evaluator? To use this online evaluator for Operation Dissolved Oxygen Level, enter Dissolved Oxygen Saturation (DS), Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Correction Factor (Cf) & Temperature (T) and hit the calculate button.

FAQs on Operation Dissolved Oxygen Level

What is the formula to find Operation Dissolved Oxygen Level?
The formula of Operation Dissolved Oxygen Level is expressed as Operation Dissolved Oxygen = Dissolved Oxygen Saturation-((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*Correction Factor*(1.024)^(Temperature-20))). Here is an example- -804434.256811 = 5.803-((8.33333333333333E-07*9.17)/(5.63888888888889E-07*0.5*(1.024)^(85-20))).
How to calculate Operation Dissolved Oxygen Level?
With Dissolved Oxygen Saturation (DS), Oxygen Transferred (N), Oxygen Transfer Capacity (Ns), Correction Factor (Cf) & Temperature (T) we can find Operation Dissolved Oxygen Level using the formula - Operation Dissolved Oxygen = Dissolved Oxygen Saturation-((Oxygen Transferred*9.17)/(Oxygen Transfer Capacity*Correction Factor*(1.024)^(Temperature-20))).
Can the Operation Dissolved Oxygen Level be negative?
No, the Operation Dissolved Oxygen Level, measured in Density cannot be negative.
Which unit is used to measure Operation Dissolved Oxygen Level?
Operation Dissolved Oxygen Level is usually measured using the Milligram per Liter[mg/L] for Density. Kilogram per Cubic Meter[mg/L], Kilogram per Cubic Centimeter[mg/L], Gram per Cubic Meter[mg/L] are the few other units in which Operation Dissolved Oxygen Level can be measured.
Copied!