Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment Formula

Fx Copy
LaTeX Copy
Observed Flow Volume is the recorded the quantity of water that would have flowed in a river past a particular point in a particular period. Check FAQs
Ro=Y-Ab-ΔSv
Ro - Observed Flow Volume?Y - Yield of Catchment?Ab - Abstraction in Time?ΔSv - Change in Storage Volumes?

Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment Example

With values
With units
Only example

Here is how the Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment equation looks like with Values.

Here is how the Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment equation looks like with Units.

Here is how the Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment equation looks like.

51Edit=186Edit-115Edit-20Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment

Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment Solution

Follow our step by step solution on how to calculate Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment?

FIRST Step Consider the formula
Ro=Y-Ab-ΔSv
Next Step Substitute values of Variables
Ro=186-115-20
Next Step Prepare to Evaluate
Ro=186-115-20
LAST Step Evaluate
Ro=51m³/s

Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment Formula Elements

Variables
Observed Flow Volume
Observed Flow Volume is the recorded the quantity of water that would have flowed in a river past a particular point in a particular period.
Symbol: Ro
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Yield of Catchment
Yield of Catchment at a time period by influenced by water balance equation.
Symbol: Y
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Abstraction in Time
Abstraction in Time in time for irrigation, water supply and industrial use and inclusive of evaporation losses in surface water bodies on the stream.
Symbol: Ab
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Change in Storage Volumes
Change in Storage Volumes of water storage bodies on the stream is the difference of water incoming and outgoing.
Symbol: ΔSv
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other formulas in Yield of Catchment category

​Go Yield of Catchment by Water Balance Equation
Y=RN+Vr
​Go Natural Flow given Yield of Catchment
RN=Y-Vr
​Go Volume of Return Flow given Yield of Catchment
Vr=Y-RN
​Go Abstraction in Time given Yield of Catchment
Ab=Y-Ro-ΔSv

How to Evaluate Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment?

Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment evaluator uses Observed Flow Volume = Yield of Catchment-Abstraction in Time-Change in Storage Volumes to evaluate the Observed Flow Volume, The Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment formula is defined as the recorded flow of water occurring on the ground surface when excess rainwater, stormwater, meltwater, or other sources, can no longer sufficiently rapidly infiltrate in soil. Observed Flow Volume is denoted by Ro symbol.

How to evaluate Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment using this online evaluator? To use this online evaluator for Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment, enter Yield of Catchment (Y), Abstraction in Time (Ab) & Change in Storage Volumes (ΔSv) and hit the calculate button.

FAQs on Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment

What is the formula to find Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment?
The formula of Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment is expressed as Observed Flow Volume = Yield of Catchment-Abstraction in Time-Change in Storage Volumes. Here is an example- 51 = 186-115-20.
How to calculate Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment?
With Yield of Catchment (Y), Abstraction in Time (Ab) & Change in Storage Volumes (ΔSv) we can find Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment using the formula - Observed Flow Volume = Yield of Catchment-Abstraction in Time-Change in Storage Volumes.
Can the Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment be negative?
No, the Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment?
Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Observed Runoff Volume at Terminal Gauging Station given Yield of Catchment can be measured.
Copied!