Fx Copy
LaTeX Copy
The Nusselt Number is the ratio of convective to conductive heat transfer at a boundary in a fluid. Convection includes both advection and diffusion. Check FAQs
Nu=1.25(Pe0.413)
Nu - Nusselt Number?Pe - Peclet Number?

Nusselt number for liquids with higher Peclet number Example

With values
With units
Only example

Here is how the Nusselt number for liquids with higher Peclet number equation looks like with Values.

Here is how the Nusselt number for liquids with higher Peclet number equation looks like with Units.

Here is how the Nusselt number for liquids with higher Peclet number equation looks like.

1.1632Edit=1.25(0.84Edit0.413)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Nusselt number for liquids with higher Peclet number

Nusselt number for liquids with higher Peclet number Solution

Follow our step by step solution on how to calculate Nusselt number for liquids with higher Peclet number?

FIRST Step Consider the formula
Nu=1.25(Pe0.413)
Next Step Substitute values of Variables
Nu=1.25(0.840.413)
Next Step Prepare to Evaluate
Nu=1.25(0.840.413)
Next Step Evaluate
Nu=1.16315437394017
LAST Step Rounding Answer
Nu=1.1632

Nusselt number for liquids with higher Peclet number Formula Elements

Variables
Nusselt Number
The Nusselt Number is the ratio of convective to conductive heat transfer at a boundary in a fluid. Convection includes both advection and diffusion.
Symbol: Nu
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Peclet Number
Peclet number is a measure of the relative importance of advection versus diffusion, where a large number indicates an advectively dominated distribution, and a small number indicates a diffuse flow.
Symbol: Pe
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Nusselt Number

​Go Nusselt Number based on Diameter
Nu=(0.35+0.56(Re0.52))Pr0.33
​Go Nusselt number for liquids and gases
Nu=(0.43+0.50(Re0.5))Pr0.38
​Go Nusselt number when property variation is larger due to temperature variation
Nu=0.25(Re0.6)(Pr0.38)(PfPrw)0.25
​Go Nusselt number given dynamic viscosity
Nu=(0.4(Re0.5)+0.06(Re0.67))(Pr0.4)(μμw)0.25

How to Evaluate Nusselt number for liquids with higher Peclet number?

Nusselt number for liquids with higher Peclet number evaluator uses Nusselt Number = 1.25*(Peclet Number^0.413) to evaluate the Nusselt Number, Nusselt number for liquids with higher Peclet number formula is defined as a dimensionless value that characterizes convective heat transfer between a fluid and a solid surface, particularly in flow over cylinders, where the Peclet number is high, and is used to analyze and predict heat transfer rates in various engineering applications. Nusselt Number is denoted by Nu symbol.

How to evaluate Nusselt number for liquids with higher Peclet number using this online evaluator? To use this online evaluator for Nusselt number for liquids with higher Peclet number, enter Peclet Number (Pe) and hit the calculate button.

FAQs on Nusselt number for liquids with higher Peclet number

What is the formula to find Nusselt number for liquids with higher Peclet number?
The formula of Nusselt number for liquids with higher Peclet number is expressed as Nusselt Number = 1.25*(Peclet Number^0.413). Here is an example- 1.163154 = 1.25*(0.84^0.413).
How to calculate Nusselt number for liquids with higher Peclet number?
With Peclet Number (Pe) we can find Nusselt number for liquids with higher Peclet number using the formula - Nusselt Number = 1.25*(Peclet Number^0.413).
What are the other ways to Calculate Nusselt Number?
Here are the different ways to Calculate Nusselt Number-
  • Nusselt Number=(0.35+0.56*(Reynolds Number^0.52))*Prandtl Number^0.33OpenImg
  • Nusselt Number=(0.43+0.50*(Reynolds Number^0.5))*Prandtl Number^0.38OpenImg
  • Nusselt Number=0.25*(Reynolds Number^0.6)*(Prandtl Number^0.38)*(Prandtl Number at Film Temperature/Prandtl Number at Wall Temperature)^0.25OpenImg
Copied!