The Nusselt Number is the ratio of convective to conductive heat transfer at a boundary in a fluid. Convection includes both advection and diffusion. Check FAQs
Nu=2+(0.386(RePr)0.5)
Nu - Nusselt Number?Re - Reynolds Number?Pr - Prandtl Number?

Nusselt number for liquid metals Example

With values
With units
Only example

Here is how the Nusselt number for liquid metals equation looks like with Values.

Here is how the Nusselt number for liquid metals equation looks like with Units.

Here is how the Nusselt number for liquid metals equation looks like.

378.2263Edit=2+(0.386(50000Edit19Edit)0.5)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Nusselt number for liquid metals

Nusselt number for liquid metals Solution

Follow our step by step solution on how to calculate Nusselt number for liquid metals?

FIRST Step Consider the formula
Nu=2+(0.386(RePr)0.5)
Next Step Substitute values of Variables
Nu=2+(0.386(5000019)0.5)
Next Step Prepare to Evaluate
Nu=2+(0.386(5000019)0.5)
Next Step Evaluate
Nu=378.226261709626
LAST Step Rounding Answer
Nu=378.2263

Nusselt number for liquid metals Formula Elements

Variables
Nusselt Number
The Nusselt Number is the ratio of convective to conductive heat transfer at a boundary in a fluid. Convection includes both advection and diffusion.
Symbol: Nu
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Reynolds Number
The Reynolds number is the ratio of inertial forces to viscous forces within a fluid which is subjected to relative internal movement due to different fluid velocities.
Symbol: Re
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Prandtl Number
The Prandtl number (Pr) or Prandtl group is a dimensionless number, named after the German physicist Ludwig Prandtl, defined as the ratio of momentum diffusivity to thermal diffusivity.
Symbol: Pr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.

Other Formulas to find Nusselt Number

​Go Nusselt number
Nu=0.37Re0.6
​Go Nusselt number for gases
Nu=2+(0.25Re+(310-4)(Re1.6))0.5
​Go Nusselt number for air
Nu=430+((5(10-3))(Re))+((0.025(10-9))(Re2))-((3.1(10-17))(Re3))
​Go Nusselt number for liquids for external flow
Nu=0.97+0.68(Re0.5)Pr-0.3

How to Evaluate Nusselt number for liquid metals?

Nusselt number for liquid metals evaluator uses Nusselt Number = 2+(0.386*(Reynolds Number*Prandtl Number)^0.5) to evaluate the Nusselt Number, Nusselt number for liquid metals formula is defined as a dimensionless value that characterizes convective heat transfer between a solid surface and a fluid, particularly in the context of flow over a sphere, providing a crucial parameter in understanding heat transfer mechanisms in various engineering applications. Nusselt Number is denoted by Nu symbol.

How to evaluate Nusselt number for liquid metals using this online evaluator? To use this online evaluator for Nusselt number for liquid metals, enter Reynolds Number (Re) & Prandtl Number (Pr) and hit the calculate button.

FAQs on Nusselt number for liquid metals

What is the formula to find Nusselt number for liquid metals?
The formula of Nusselt number for liquid metals is expressed as Nusselt Number = 2+(0.386*(Reynolds Number*Prandtl Number)^0.5). Here is an example- 378.2263 = 2+(0.386*(50000*19)^0.5).
How to calculate Nusselt number for liquid metals?
With Reynolds Number (Re) & Prandtl Number (Pr) we can find Nusselt number for liquid metals using the formula - Nusselt Number = 2+(0.386*(Reynolds Number*Prandtl Number)^0.5).
What are the other ways to Calculate Nusselt Number?
Here are the different ways to Calculate Nusselt Number-
  • Nusselt Number=0.37*Reynolds Number^0.6OpenImg
  • Nusselt Number=2+(0.25*Reynolds Number+(3*10^-4)*(Reynolds Number^1.6))^0.5OpenImg
  • Nusselt Number=430+((5*(10^-3))*(Reynolds Number))+((0.025*(10^-9))*(Reynolds Number^2))-((3.1*(10^-17))*(Reynolds Number^3))OpenImg
Copied!