Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading Formula

Fx Copy
LaTeX Copy
Number of Tubes in Heat Exchanger refers to the count of individual tubes that form the heat transfer surface inside the heat exchanger. Check FAQs
Nt=WcΓhLt
Nt - Number of Tubes in Heat Exchanger?Wc - Condensate Flow?Γh - Horizontal Tube Loading?Lt - Length of Tube in Heat Exchanger?

Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading Example

With values
With units
Only example

Here is how the Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading equation looks like with Values.

Here is how the Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading equation looks like with Units.

Here is how the Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading equation looks like.

360.0087Edit=12.45Edit0.0077Edit4500Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading

Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading Solution

Follow our step by step solution on how to calculate Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading?

FIRST Step Consider the formula
Nt=WcΓhLt
Next Step Substitute values of Variables
Nt=12.45kg/s0.00774500mm
Next Step Convert Units
Nt=12.45kg/s0.00774.5m
Next Step Prepare to Evaluate
Nt=12.450.00774.5
Next Step Evaluate
Nt=360.008674907829
LAST Step Rounding Answer
Nt=360.0087

Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading Formula Elements

Variables
Number of Tubes in Heat Exchanger
Number of Tubes in Heat Exchanger refers to the count of individual tubes that form the heat transfer surface inside the heat exchanger.
Symbol: Nt
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Condensate Flow
Condensate Flow refers to the flowrate of the liquid condensate formed due to condensation of vapors in a condenser type heat exchanger.
Symbol: Wc
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Horizontal Tube Loading
Horizontal Tube Loading refers to the film formation of liquid condensate over the tubes inclined in horizontal orientation in a condenser type heat exchanger.
Symbol: Γh
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Length of Tube in Heat Exchanger
Length of tube in Heat Exchanger is the length which will be used during heat transfer in a heat exchanger.
Symbol: Lt
Measurement: LengthUnit: mm
Note: Value should be greater than 0.

Other formulas in Heat Transfer Coefficient in Heat Exchangers category

​Go Heat Transfer Coefficient for Condensation Inside Vertical Tubes
haverage=0.926kf((ρfμ)(ρf-ρV)[g](πDiNtMf))13
​Go Heat Transfer Coefficient for Condensation Outside Horizontal Tubes
haverage=0.95kf((ρf(ρf-ρV)([g]μ)(NtLtMf))13)(NVertical-16)
​Go Heat Transfer Coefficient for Condensation Outside Vertical Tubes
haverage=0.926kf((ρfμ)(ρf-ρV)[g](πDONtMf))13
​Go Heat Transfer Coefficient for Plate Heat Exchanger
hp=0.26(kfde)(Re0.65)(Pr0.4)(μμW)0.14

How to Evaluate Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading?

Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading evaluator uses Number of Tubes in Heat Exchanger = Condensate Flow/(Horizontal Tube Loading*Length of Tube in Heat Exchanger) to evaluate the Number of Tubes in Heat Exchanger, The Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading formula refers to the total count of tubes arranged horizontally within the condenser unit. Number of Tubes in Heat Exchanger is denoted by Nt symbol.

How to evaluate Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading using this online evaluator? To use this online evaluator for Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading, enter Condensate Flow (Wc), Horizontal Tube Loading h) & Length of Tube in Heat Exchanger (Lt) and hit the calculate button.

FAQs on Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading

What is the formula to find Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading?
The formula of Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading is expressed as Number of Tubes in Heat Exchanger = Condensate Flow/(Horizontal Tube Loading*Length of Tube in Heat Exchanger). Here is an example- 360.0087 = 12.45/(0.007685*4.5).
How to calculate Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading?
With Condensate Flow (Wc), Horizontal Tube Loading h) & Length of Tube in Heat Exchanger (Lt) we can find Number of Tubes in Horizontal Condenser given Condensate Flowrate and Tube Loading using the formula - Number of Tubes in Heat Exchanger = Condensate Flow/(Horizontal Tube Loading*Length of Tube in Heat Exchanger).
Copied!