Number of Lamps Required for Illumination Formula

Fx Copy
LaTeX Copy
Number of lamps refers to the quantity of individual light sources used in a lighting system. It represents the count of separate lamps employed to provide illumination in a given space. Check FAQs
NLamp=EvAFUFMF
NLamp - Number of Lamp?Ev - Illumination Intensity?A - Area of Illumination?F - Luminous Flux?UF - Utilization Factor?MF - Maintenance Factor?

Number of Lamps Required for Illumination Example

With values
With units
Only example

Here is how the Number of Lamps Required for Illumination equation looks like with Values.

Here is how the Number of Lamps Required for Illumination equation looks like with Units.

Here is how the Number of Lamps Required for Illumination equation looks like.

3Edit=1Edit41Edit42Edit0Edit2Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Utilization of Electrical Energy » fx Number of Lamps Required for Illumination

Number of Lamps Required for Illumination Solution

Follow our step by step solution on how to calculate Number of Lamps Required for Illumination?

FIRST Step Consider the formula
NLamp=EvAFUFMF
Next Step Substitute values of Variables
NLamp=1lx4142lm02
Next Step Prepare to Evaluate
NLamp=1414202
Next Step Evaluate
NLamp=3.31904761904762
LAST Step Rounding Answer
NLamp=3

Number of Lamps Required for Illumination Formula Elements

Variables
Number of Lamp
Number of lamps refers to the quantity of individual light sources used in a lighting system. It represents the count of separate lamps employed to provide illumination in a given space.
Symbol: NLamp
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Illumination Intensity
Illumination intensity refers to the level or strength of light in a given area. It quantifies the amount of light reaching a surface and is typically measured in units such as lux or foot-candles.
Symbol: Ev
Measurement: IlluminanceUnit: lx
Note: Value can be positive or negative.
Area of Illumination
Area of illumination refers to the size or extent of the space covered by light from a source, determining the reach and coverage of light in that area.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Luminous Flux
Luminous flux is a measure of the total amount of light emitted by a light source in all directions. It quantifies the overall brightness or output of the source.
Symbol: F
Measurement: Luminous FluxUnit: lm
Note: Value can be positive or negative.
Utilization Factor
Utilization factor refers to a percentage or factor that represents the efficiency or effectiveness of a lighting system in delivering and utilizing light to the intended area or task.
Symbol: UF
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Maintenance Factor
Maintenance factor refers to a multiplier or percentage used to adjust the initial illumination levels of a lighting system to account for degradation and dirt accumulation over time.
Symbol: MF
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Illumination Parameters category

​Go Solid Angle
ω=Ar2
​Go Reduction Factor
RF=M.S.C.P.M.H.C.P.
​Go Mean Spherical Candle Power
M.S.C.P.=F4π
​Go Mean Horizontal Candle Power
M.H.C.P.=SNLamp

How to Evaluate Number of Lamps Required for Illumination?

Number of Lamps Required for Illumination evaluator uses Number of Lamp = (Illumination Intensity*Area of Illumination)/(Luminous Flux*Utilization Factor*Maintenance Factor) to evaluate the Number of Lamp, The Number of lamps Required for Illumination formula is defined as the ratio of the product of illumination & area to the product of luminous flux, utilization factor, maintenance fator. Number of Lamp is denoted by NLamp symbol.

How to evaluate Number of Lamps Required for Illumination using this online evaluator? To use this online evaluator for Number of Lamps Required for Illumination, enter Illumination Intensity (Ev), Area of Illumination (A), Luminous Flux (F), Utilization Factor (UF) & Maintenance Factor (MF) and hit the calculate button.

FAQs on Number of Lamps Required for Illumination

What is the formula to find Number of Lamps Required for Illumination?
The formula of Number of Lamps Required for Illumination is expressed as Number of Lamp = (Illumination Intensity*Area of Illumination)/(Luminous Flux*Utilization Factor*Maintenance Factor). Here is an example- 3 = (1.02*41)/(42*0.15*2).
How to calculate Number of Lamps Required for Illumination?
With Illumination Intensity (Ev), Area of Illumination (A), Luminous Flux (F), Utilization Factor (UF) & Maintenance Factor (MF) we can find Number of Lamps Required for Illumination using the formula - Number of Lamp = (Illumination Intensity*Area of Illumination)/(Luminous Flux*Utilization Factor*Maintenance Factor).
Copied!