Normalized Voltage of Single Phase Thyristor Converter with Resistive Load Formula

Fx Copy
LaTeX Copy
Normalized Output Voltage Thyristor Converter is found be normalizing the average output voltage with maximum voltage in a thyristor converter based circuit. Check FAQs
Vn(thy)=0.5(1+cos(αd(thy)))
Vn(thy) - Normalized Output Voltage Thyristor Converter?αd(thy) - Delay Angle of Thyristor Converter?

Normalized Voltage of Single Phase Thyristor Converter with Resistive Load Example

With values
With units
Only example

Here is how the Normalized Voltage of Single Phase Thyristor Converter with Resistive Load equation looks like with Values.

Here is how the Normalized Voltage of Single Phase Thyristor Converter with Resistive Load equation looks like with Units.

Here is how the Normalized Voltage of Single Phase Thyristor Converter with Resistive Load equation looks like.

0.6694Edit=0.5(1+cos(70.2Edit))
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Normalized Voltage of Single Phase Thyristor Converter with Resistive Load

Normalized Voltage of Single Phase Thyristor Converter with Resistive Load Solution

Follow our step by step solution on how to calculate Normalized Voltage of Single Phase Thyristor Converter with Resistive Load?

FIRST Step Consider the formula
Vn(thy)=0.5(1+cos(αd(thy)))
Next Step Substitute values of Variables
Vn(thy)=0.5(1+cos(70.2°))
Next Step Convert Units
Vn(thy)=0.5(1+cos(1.2252rad))
Next Step Prepare to Evaluate
Vn(thy)=0.5(1+cos(1.2252))
Next Step Evaluate
Vn(thy)=0.669368960122754
LAST Step Rounding Answer
Vn(thy)=0.6694

Normalized Voltage of Single Phase Thyristor Converter with Resistive Load Formula Elements

Variables
Functions
Normalized Output Voltage Thyristor Converter
Normalized Output Voltage Thyristor Converter is found be normalizing the average output voltage with maximum voltage in a thyristor converter based circuit.
Symbol: Vn(thy)
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Delay Angle of Thyristor Converter
Delay Angle of Thyristor Converter refers to the angle at which the thyristor is triggered to start conducting current in an AC (alternating current) circuit.
Symbol: αd(thy)
Measurement: AngleUnit: °
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other formulas in Single Phase Thyristor Converter category

​Go Average Output Voltage of Single Phase Thyristor Converter with Resistive Load
Vavg(thy)=(Vin(thy)2π)(1+cos(αd(thy)))
​Go Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load
Vom(thy)=Vin(thy)π
​Go RMS Output Voltage of Single Phase Thyristor Converter with Resistive Load
Vrms(thy)=(Vin(thy)2)(180-αd(thy)180+(0.5π)sin(2αd(thy)))0.5
​Go Average Load Voltage for Calculus Function
Vavg(thy)=((12π)(Vin(thy)sin(x),x,αf(thy),π))

How to Evaluate Normalized Voltage of Single Phase Thyristor Converter with Resistive Load?

Normalized Voltage of Single Phase Thyristor Converter with Resistive Load evaluator uses Normalized Output Voltage Thyristor Converter = 0.5*(1+cos(Delay Angle of Thyristor Converter)) to evaluate the Normalized Output Voltage Thyristor Converter, The Normalized voltage of single phase thyristor converter with resistive load formula is found by normalizing the average output voltage concerning maximum voltage. Normalized Output Voltage Thyristor Converter is denoted by Vn(thy) symbol.

How to evaluate Normalized Voltage of Single Phase Thyristor Converter with Resistive Load using this online evaluator? To use this online evaluator for Normalized Voltage of Single Phase Thyristor Converter with Resistive Load, enter Delay Angle of Thyristor Converter d(thy)) and hit the calculate button.

FAQs on Normalized Voltage of Single Phase Thyristor Converter with Resistive Load

What is the formula to find Normalized Voltage of Single Phase Thyristor Converter with Resistive Load?
The formula of Normalized Voltage of Single Phase Thyristor Converter with Resistive Load is expressed as Normalized Output Voltage Thyristor Converter = 0.5*(1+cos(Delay Angle of Thyristor Converter)). Here is an example- 0.67101 = 0.5*(1+cos(1.22522113489979)).
How to calculate Normalized Voltage of Single Phase Thyristor Converter with Resistive Load?
With Delay Angle of Thyristor Converter d(thy)) we can find Normalized Voltage of Single Phase Thyristor Converter with Resistive Load using the formula - Normalized Output Voltage Thyristor Converter = 0.5*(1+cos(Delay Angle of Thyristor Converter)). This formula also uses Cosine (cos) function(s).
Copied!