Normalized Value of Fall given Discharge Formula

Fx Copy
LaTeX Copy
Normalized Value of Fall to be constant at all stages. Check FAQs
Fo=F(Q0Qa)1m
Fo - Normalized Value of Fall?F - Actual Fall?Q0 - Normalized Discharge?Qa - Actual Discharge?m - Exponent on Rating Curve?

Normalized Value of Fall given Discharge Example

With values
With units
Only example

Here is how the Normalized Value of Fall given Discharge equation looks like with Values.

Here is how the Normalized Value of Fall given Discharge equation looks like with Units.

Here is how the Normalized Value of Fall given Discharge equation looks like.

1.5123Edit=2.5Edit(7Edit9Edit)10.5Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Normalized Value of Fall given Discharge

Normalized Value of Fall given Discharge Solution

Follow our step by step solution on how to calculate Normalized Value of Fall given Discharge?

FIRST Step Consider the formula
Fo=F(Q0Qa)1m
Next Step Substitute values of Variables
Fo=2.5m(7m³/s9m³/s)10.5
Next Step Prepare to Evaluate
Fo=2.5(79)10.5
Next Step Evaluate
Fo=1.51234567901235m
LAST Step Rounding Answer
Fo=1.5123m

Normalized Value of Fall given Discharge Formula Elements

Variables
Normalized Value of Fall
Normalized Value of Fall to be constant at all stages.
Symbol: Fo
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Actual Fall
Actual Fall at a given stage to that of the actual discharge.
Symbol: F
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Normalized Discharge
Normalized Discharge at the given stage when the fall is equal to normalized value of the fall taken to be constant at all stages.
Symbol: Q0
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Actual Discharge
Actual discharge is given by the actual area and velocity.
Symbol: Qa
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Exponent on Rating Curve
Exponent on rating curve with a value close to 0.5, Rating curve is a graph of discharge versus stage for given point on stream, usually at gauging stations.
Symbol: m
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other formulas in Stage Discharge Relationship category

​Go Actual Discharge from Backwater Effect on Rating Curve Normalized Curve
Qa=Q0(FFo)m
​Go Normalized Discharge of Backwater Effect on Rating Curve Normalized Curve
Q0=Qa(FoF)m
​Go Actual Fall at Stage given Actual Discharge
F=Fo(QaQ0)1m
​Go Relationship between Stage and Discharge for Non-Alluvial Rivers
Qs=Cr(G-a)β

How to Evaluate Normalized Value of Fall given Discharge?

Normalized Value of Fall given Discharge evaluator uses Normalized Value of Fall = Actual Fall*(Normalized Discharge/Actual Discharge)^(1/Exponent on Rating Curve) to evaluate the Normalized Value of Fall, The Normalized Value of Fall given Discharge formula is defined as the taken to be constant at all stages to the normalized discharge at the given stage when the fall is equal to the normalized fall. Normalized Value of Fall is denoted by Fo symbol.

How to evaluate Normalized Value of Fall given Discharge using this online evaluator? To use this online evaluator for Normalized Value of Fall given Discharge, enter Actual Fall (F), Normalized Discharge (Q0), Actual Discharge (Qa) & Exponent on Rating Curve (m) and hit the calculate button.

FAQs on Normalized Value of Fall given Discharge

What is the formula to find Normalized Value of Fall given Discharge?
The formula of Normalized Value of Fall given Discharge is expressed as Normalized Value of Fall = Actual Fall*(Normalized Discharge/Actual Discharge)^(1/Exponent on Rating Curve). Here is an example- 1.512346 = 2.5*(7/9)^(1/0.5).
How to calculate Normalized Value of Fall given Discharge?
With Actual Fall (F), Normalized Discharge (Q0), Actual Discharge (Qa) & Exponent on Rating Curve (m) we can find Normalized Value of Fall given Discharge using the formula - Normalized Value of Fall = Actual Fall*(Normalized Discharge/Actual Discharge)^(1/Exponent on Rating Curve).
Can the Normalized Value of Fall given Discharge be negative?
No, the Normalized Value of Fall given Discharge, measured in Length cannot be negative.
Which unit is used to measure Normalized Value of Fall given Discharge?
Normalized Value of Fall given Discharge is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Normalized Value of Fall given Discharge can be measured.
Copied!