Normal Rainfall in Monsoon Season Formula

Fx Copy
LaTeX Copy
The Normal Rainfall in Monsoon Season refers to the statistical average of rainfall measured over a specified period, typically 30 years, during the monsoon months in a given region. Check FAQs
Pnm=RrfmfAcr
Pnm - Normal Rainfall in Monsoon Season?Rrfm - Recharge from Rainfall in Monsoon Season?f - Rainfall Infiltration Factor?Acr - Area of Computation for Recharge?

Normal Rainfall in Monsoon Season Example

With values
With units
Only example

Here is how the Normal Rainfall in Monsoon Season equation looks like with Values.

Here is how the Normal Rainfall in Monsoon Season equation looks like with Units.

Here is how the Normal Rainfall in Monsoon Season equation looks like.

0.0239Edit=7Edit22Edit13.3Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Normal Rainfall in Monsoon Season

Normal Rainfall in Monsoon Season Solution

Follow our step by step solution on how to calculate Normal Rainfall in Monsoon Season?

FIRST Step Consider the formula
Pnm=RrfmfAcr
Next Step Substitute values of Variables
Pnm=7m³/s2213.3
Next Step Prepare to Evaluate
Pnm=72213.3
Next Step Evaluate
Pnm=0.0239234449760766m
LAST Step Rounding Answer
Pnm=0.0239m

Normal Rainfall in Monsoon Season Formula Elements

Variables
Normal Rainfall in Monsoon Season
The Normal Rainfall in Monsoon Season refers to the statistical average of rainfall measured over a specified period, typically 30 years, during the monsoon months in a given region.
Symbol: Pnm
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Recharge from Rainfall in Monsoon Season
Recharge from Rainfall in Monsoon Season is the infiltration and percolation of rainwater into subsurface aquifers, primarily occurring during the monsoon period when rainfall is significantly higher.
Symbol: Rrfm
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Rainfall Infiltration Factor
The Rainfall Infiltration Factor refers to the measure of the rate at which water from rainfall penetrates into the soil, a critical parameter, influencing design and management of water resources.
Symbol: f
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Area of Computation for Recharge
The Area of Computation for Recharge refers to the catchment area where the amount of water infiltrating the ground and replenishing aquifers is calculated, crucial for managing groundwater resources.
Symbol: Acr
Measurement: AreaUnit:
Note: Value can be positive or negative.

Other formulas in Rainfall Infiltration Method category

​Go Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method
Rrfm=fAcrPnm
​Go Rainfall Infiltration Factor when Recharge from Rainfall is Considered
f=RrfmAcrPnm
​Go Catchment Area when Recharge from Rainfall is Considered
Acr=RrfmfPnm

How to Evaluate Normal Rainfall in Monsoon Season?

Normal Rainfall in Monsoon Season evaluator uses Normal Rainfall in Monsoon Season = Recharge from Rainfall in Monsoon Season/(Rainfall Infiltration Factor*Area of Computation for Recharge) to evaluate the Normal Rainfall in Monsoon Season, The Normal Rainfall in Monsoon Season formula is defined as the average precipitation that occurs during the monsoon period, typically calculated over a long period (e.g., 30 years). This average serves as a benchmark to compare actual rainfall during a given monsoon season. Normal Rainfall in Monsoon Season is denoted by Pnm symbol.

How to evaluate Normal Rainfall in Monsoon Season using this online evaluator? To use this online evaluator for Normal Rainfall in Monsoon Season, enter Recharge from Rainfall in Monsoon Season (Rrfm), Rainfall Infiltration Factor (f) & Area of Computation for Recharge (Acr) and hit the calculate button.

FAQs on Normal Rainfall in Monsoon Season

What is the formula to find Normal Rainfall in Monsoon Season?
The formula of Normal Rainfall in Monsoon Season is expressed as Normal Rainfall in Monsoon Season = Recharge from Rainfall in Monsoon Season/(Rainfall Infiltration Factor*Area of Computation for Recharge). Here is an example- 0.023923 = 7/(22*13.3).
How to calculate Normal Rainfall in Monsoon Season?
With Recharge from Rainfall in Monsoon Season (Rrfm), Rainfall Infiltration Factor (f) & Area of Computation for Recharge (Acr) we can find Normal Rainfall in Monsoon Season using the formula - Normal Rainfall in Monsoon Season = Recharge from Rainfall in Monsoon Season/(Rainfall Infiltration Factor*Area of Computation for Recharge).
Can the Normal Rainfall in Monsoon Season be negative?
Yes, the Normal Rainfall in Monsoon Season, measured in Length can be negative.
Which unit is used to measure Normal Rainfall in Monsoon Season?
Normal Rainfall in Monsoon Season is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Normal Rainfall in Monsoon Season can be measured.
Copied!